• Title/Summary/Keyword: Method of symmetrical components

Search Result 33, Processing Time 0.02 seconds

Least Square Method: A Novel Approach to Determine Symmetrical Components of Power System

  • Rehman, Bilawal;Liu, Chongru;Wang, Lili
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.39-44
    • /
    • 2017
  • This paper proposes a novel approach to determine symmetrical components of power system by applying method of least squares in time domain. For the modern power system stability, clearance of faults on high voltage transmission lines in zero response time is crucial and important. Symmetrical components have a great attention since last century. They have been found an effective tool for the analysis of symmetrical and unsymmetrical faults in power system. Moreover, magnitude of symmetrical components are also used as a caution about faults in system. With rapid changes in technology, Microprocessor assumed to be fastest machine of the modern era. Hence microprocessor based techniques were developed and implemented for last few decades. The proposed technique apply least square method in the computation of symmetrical components which is suitable as an application in microprocessor based monitoring and controlling power system in order to avoid cascading failures. Simulation of proposed model is carried out in MATLAB/SIMULINK and all results exploit the validity of model.

A New Distribution System Power Flow Method Using Symmetrical Components (대칭성분을 이용한 3상 배전계통 조류계산 기법)

  • Choe, Jeong-Hwan;Jeong, Seong-Il;Park, Je-Yeong;Kim, Gwang-Ho;Kim, Jae-Eon;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • This paper proposes a new power flow method for distribution system analysis by modifying the conventional back/forward sweep method using symmetrical components. Since the proposed method backward and forward sweeps with the variables expressed by symmetrical components, this method reduces computation time for matrix calculations; therefore, it is able to reduce the computational burden for real-time distribution network analysis. The proposed method was also developed to effectively analyze the unbalanced distribution system installing AVR(Auto Voltage Regulator), shunt capacitors. The proposed algorithm was compared with the conventional Back/forward Sweep method by applying both methods to three phase unbalanced distribution system of IEEE 123-bus model, and the test results showed that the proposed method would outperformed the conventional method in real-time distribution system analysis.

A Study on the Digital Relaying Techniques by Real-Time Symmetrical Components of Power System (전력계통의 실시간 대칭성분을 이용한 거리계전 기법에 관한 연구)

  • 신명철;김철환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.10
    • /
    • pp.695-702
    • /
    • 1987
  • Nowadays as the power systems have been more complicated and have grown to ultra high voltage, it requires a accurate and high speed relaying scheme to improve the reliability and stability of power systems for a harmonious power supplying. For this purpose voltage and current have to be measured at the location of the protective device and the short circuit impedance must be determined. This paper presents the application methods and some results of digital distance relaying scheme which is based upon the theouy of real-time symmetrical components. Usually the symmetrical component have been used to solve the transient systems as well as the steady state systems under unbalanced systems. But, real-time symmetrical component frequently have not been applied to on-line control region of the large power system. We have tried to apply this method to deal with the various type of faults on artificial transmission line. And experimental results demonstrate the validity of the proposed techniques. Therefore, this study is expected that it is contributed to improve the reliability of power supplying, searching for the fault location rapidly and exactly in power system.

  • PDF

A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems (태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구)

  • Kim, Chan-Hyeok;Park, Hyeon-Seok;Rho, Dea-Seok;Shin, Chang-Hoon;Yoon, Gi-Gab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

A Study on the Wall Components of Sarang-taechong in the Upper Class houses of Chosun Dynasty (조선시대 상류주택 사랑대청의 실내입면구성요소에 관한 연구)

  • 오혜경;홍이경
    • Journal of Families and Better Life
    • /
    • v.18 no.2
    • /
    • pp.191-202
    • /
    • 2000
  • The purpose of this study was to clarify the wall components of Sarang-taechong in the upper class houses of Chosun dynasty. Physical trace method was used for this study. The samples were taken from the Sarang-taechong of 6 traditional Korean houses; Yunkyungdang, the ancient Chusa estate, Sunkyojang, Chunghyodang, Yangjindant, Unjorn. The makor findings were summarized as follows; 1) The common components of each wall were pillars, sanginbangs(upper horizontal beams), hainbangs (lower horizontal beams), door and windows. Changbangs(wood eave pieces that suported decoration blocks), changyos(a pice of wood fitted between the tops of pillars and upper tori cross beams), and morums(the top wainscot board laid horizontally between the bottom beam and the bottom portion of a window frame) were additional. 2) The composition of every south wall was symmetrical and the other threes were mixed symmetrical and asymmetrical. 3) The image of wall was classified-fine, strong, and modera e, according to the symmetry or asymmetry of wall composition, the width of each components, the kind of window.

  • PDF

A Design Method of Iron-cored CTs To Prevent Satruation (포화를 방지하기 위한 보호용 철심 변류기 설계 방법)

  • Lee, Ju-Hun;Gang, Sang-Hui;Gang, Yong-Cheol;Lee, Seung-Jae;Bae, Ju-Cheon;An, Jun-Gi;Lee, Cheong-Hak;Lee, Jeong-Taek
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 1999
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current without exceeding 10% ratio error. However, the possibility of CT saturation still remains if the fault current contains substantial amounts of ac and/or dc components. This paper presents a design method of iron-cored CTs for use with protective relays to prevent CT saturation. The proposed design method determines the core cross section of the CT; it employs the transient dimensioning factor to consider relay's operating time (duty cycle) and dc component as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider the biggest fault current. The method designs the cross section of CTs in cases of reclosure and no reclosure.

  • PDF

A Study on the Fuzzy-based Fault-type Detection Using Symmetrical Component (대칭성분에 의한 퍼지형 고장형태판별에 관한 연구)

  • Park, C.W.;Jeon, B.J.;Shin, M.C.;Lee, B.K.;Yun, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.857-860
    • /
    • 1997
  • This paper is on the application of fuzzy for fault-type approach using symmetrical components method. To evaluate performance of the proposed technique, we have been tested using a relaying signals obtained from EMTP simulation package.

  • PDF

Seismic Analysis of Building Structures with Ambiguous Modal Direction (모드의 방향이 불분명한 건축구조물의 지진해석)

  • 김태호;이동근;김대곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.513-520
    • /
    • 2002
  • This study is for seismic analysis of building structures with ambiguous modal direction This case is revealed symmetrical building structure or the structure that isn't coincided building axis with physical axis. Seismic analysis-time history analysis, response spectrum analysis and lateral force procedure-is carried out. It is concluded that analysis method for the structure with ambiguous modal direction don't suitable for lateral force procedure. It is recommended to use the CQC method for combining modal responses to the individual components and the SRSS rule for combining responses to the two horizontal components are of nearly equal intensities.

  • PDF

Advanced aerostatic stability analysis of suspension bridges

  • Xiao, Ru-Cheng;Cheng, Jin
    • Wind and Structures
    • /
    • v.7 no.1
    • /
    • pp.55-70
    • /
    • 2004
  • Aerostatic instability of a suspension bridge may suddenly appears when the deformed shape of the structure produces an increase in the value of the three components of displacement-dependent wind loads distributed in the structure. This paper investigates the aerostatic stability of suspension bridges using an advanced nonlinear method based on the concept of limit point instability. Particular attention is devoted to aerostatic stability analysis of symmetrical suspension bridges. A long-span symmetrical suspension bridge (Hu Men Bridge) with a main span of 888 m is chosen for analysis. It is found that the initial configuration (symmetry or asymmetry) may affect the instability configuration of structure. A finite element software for the nonlinear aerostatic stability analysis of cable-supported bridges (NASAB) is presented and discussed. The aerostatic failure mechanism of suspension bridges is also explained by tracing aerostatic instability path.

Development of Power Flow calculation algorithm in distribution Power Systems using Symmetrical Components (대칭성분을 이용한 배전계통 조류 계산 알고리즘 개발)

  • Choi, J.H.;Jeong, J.C.;Kim, K.H.;Park, J.K.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.401-403
    • /
    • 2001
  • This paper describes a power flow method for distribution systems, applying the method of symmetrical component to back/forward sweep method. The proposed algorithm is effective for unbalanced radial distribution system, with process of AVR(Auto Voltage Regulator), shunt capacitor. The proposed method was compared with the conventional Back/forward sweep method by using three phase unbalanced distribution systems of 123 nodes.

  • PDF