• Title/Summary/Keyword: Micro Chip

Search Result 530, Processing Time 0.031 seconds

The fabrication of micro mass flow sensor by Micro-machining Technology (Micromachining 기술을 이용한 micro mass flow sensor의 제작)

  • Eoh, Soo-Hae;Choi, Se-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.481-485
    • /
    • 1987
  • The fabrication of a micro mass flow sensor on a silicon chip by means of micro-machining technology is described on this paper. The operation of micro mass flow sensor is based on the heat transfer from a heated chip to a fluid. The temperature differences on the chip is a measure for the flow velocity in a plane parallel with the chip surface. An anisotropic etching technigue was used for the formation of the V-type groove in this fabrication. The micro mass flow sensor is made up of two main parts ; A thin glass plate embodying the connecting parts and mass flow sensor parts in silicon chip. This sensor have a very small size and a neglible dead space. Micro mass flow sensor can fabricate on silicon chip by micro machining technology too.

  • PDF

Design and Contact Force Control of a Flip Chip Mounting Head system

  • Kim, Kyoung-Jun;Shim, Jae-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1060-1065
    • /
    • 2003
  • This paper contributes to development of a new chip mounting head system for flip chip. Recently, the LDM(Linear DC Motor) has been widely used, because it has particular merits than the rotary type motors. In this paper, we proposed a macro/micro positioning system for force control of a chip mounting system. In the proposed macro/micro system, the macro actuator provide the system with a gross motion while the micro device yields fine tuned motion to reduce the harmful impact force that occurs between very small sized electronic parts and PCB surface. In order to prove the effectiveness of the proposed macro/micro chip mounting system, we compared the proposed chip mounting head with the conventional chip mounting head equipped with a macro actuator only. A series of experiments were executed under the mounting conditions of various access velocities and PCB stiffness. As a result of this study, a satisfactory voice coil actuator as the micro actuator has been developed, and its performance meet well the specifications desired for the design of the chip mounting head system and show good correspondence between theoretical analysis and experimental results.

  • PDF

Intelligent Force Control of a Flip Chip Mounting System

  • Shim, Jae Hong;Cho, Young Im
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.3
    • /
    • pp.316-321
    • /
    • 2004
  • In this paper, we have developed a new mounting head system for flip chip. The proposed head system consists of a macro/micro positioning actuator for stable force control. The macro actuator provides the system with a gross motion while the micro device yields fine tuned motion to reduce the harmful impact force that occurs between very small sized electronic parts and the surface of a PCB(printed circuit board). In order to show the effectiveness of the proposed macro/micro chip mounting system, we compared the proposed system with the conventional chip mounting head equipped with a macro actuator only. A series of experiments were executed under the mounting conditions such as various access velocities and PCB stiffness. As a result of this study, a satisfactory voice coil actuator as the micro actuator has been developed, and its performance meet well the specifications desired for the design of the chip mounting head system and show good correspondence between theoretical analysis and experimental results.

Operation of PCR chip by micropump (마이크로펌프를 이용한 PCR Chip의 구동)

  • 최종필;반준호;장인배;김헌영;김병희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.463-467
    • /
    • 2004
  • This paper presents the fabrication possibility of the micro actuator which uses a micro-thermal bubble, generated b micro-heater under pulse heating. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, he middle plate, the upper plate. The lower plate includes the channel and chamber are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The middle plate includes the chamber and diaphragm d the upper plate is the micro-heater. The Micropump is fabricated by bonding process of the three layer. This paper resented the possibility of the PCR chip operation by the fabricated micropump.

  • PDF

Study on Effect of the printing direction and layer thickness for micro-fluidic chip fabrication via SLA 3D printing (적층 방식 3차원 프린팅에 의한 미세유로 칩 제작 공정에서 프린팅 방향 및 적층 두께의 영향에 관한 연구)

  • Jin, Jae-Ho;Kwon, Da-in;Oh, Jae-Hwan;Kang, Do-Hyun;Kim, Kwanoh;Yoon, Jae-Sung;Yoo, Yeong-Eun
    • Design & Manufacturing
    • /
    • v.16 no.3
    • /
    • pp.58-65
    • /
    • 2022
  • Micro-fluidic chip has been fabricated by lithography process on silicon or glass wafer, casting using PDMS, injection molding of thermoplastics or 3D printing, etc. Among these processes, 3D printing can fabricate micro-fluidic chip directly from the design without master or template for fluidic channel fabricated previously. Due to this direct printing, 3D printing provides very fast and economical method for prototyping micro-fluidic chip comparing to conventional fabrication process such as lithography, PDMS casting or injection molding. Although 3D printing is now used more extensively due to this fast and cheap process done automatically by single printing machine, there are some issues on accuracy or surface characteristics, etc. The accuracy of the shape and size of the micro-channel is limited by the resolution of the printing and printing direction or layering direction in case of SLM type of 3D printing using UV curable resin. In this study, the printing direction and thickness of each printing layer are investigated to see the effect on the size, shape and surface of the micro-channel. A set of micro-channels with different size was designed and arrayed orthogonal. Micro-fluidic chips are 3D printed in different directions to the micro-channel, orthogonal, parallel, or skewed. The shape of the cross-section of the micro-channel and the surface of the micro-channel are photographed using optical microscopy. From a series of experiments, an optimal printing direction and process conditions are investigated for 3D printing of micro-fluidic chip.

Fabrication of PMMA Micro CE Chip Using IPA Assisted Low-temperature Bonding (IPA 저온 접합법을 이용한 PMMA Micro CE Chip의 제작)

  • Cha, Nam-Goo;Park, Chang-Hwa;Lim, Hyun-Woo;Cho, Min-Soo;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2006
  • This paper reports an improved bonding method using the IPA (isopropyl alcohol) assisted low-temperature bonding process for the PMMA (polymethylmethacrylate) micro CE (capillary electrophoresis) chip. There is a problem about channel deformations during the conventional processes such as thermal bonding and solvent bonding methods. The bonding test using an IPA showed good results without channel deformations over 4 inch PMMA wafer at $60^{\circ}C$ and 1.3 bar for 10 minutes. The mechanism of IPA bonding was attributed to the formation of a small amount of vaporized acetone made from the oxidized IPA which allows to solvent bonding. To verify the usefulness of the IPA assisted low-temperature bonding process, the PMMA micro CE chip which had a $45{\mu}m$ channel height was fabricated by hot embossing process. A functional test of the fabricated CE chip was demonstrated by the separation of fluorescein and dichlorofluorescein. Any leakage of liquids was not observed during the test and the electropherogram result was successfully achieved. An IPA assisted low-temperature bonding process could be an easy and effective way to fabricate the PMMA micro CE chip and would help to increase the yield.

Microfluidic Device for Bio Analytical Systems

  • Junhong Min;Kim, Joon-Ho;Kim, Sanghyo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.100-106
    • /
    • 2004
  • Micro-fluidics is one of the major technologies used in developing micro-total analytical systems (${\mu}$-TAS), also known as “lab-on-a-chip”. With this technology, the analytical capabilities of room-size laboratories can be put on one small chip. In this paper, we will briefly introduce materials that can be used in micro-fluidic systems and a few modules (mixer, chamber, and sample prep. modules) for lab-on-a-chip to analyze biological samples. This is because a variety of fields have to be combined with micro-fluidic technologies in order to realize lab-on-a-chip.

Fabrication of plastic CE (capillary electrophoresis) microchip by hot embossing process (핫 엠보싱 공정을 이용한 플라스틱 CE(capillary electrophoresis) 마이크로 칩의 제작)

  • Cha Nam-Goo;Park Chang-Hwa;Lim Hyun-Woo;Park Jin-Goo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1140-1144
    • /
    • 2005
  • A plastic-based CE (capillary electrophoresis) microchip was fabricated by hot embossing process. A Si mold was made by wet etching process and a PMMA wafer was cut off from 1mm thick PMMA sheet. A micro-channel structure on PMMA substrate was produced by hot embossing process using the Si mold and the PMMA wafer. A vacuum assisted thermal bonding procedure was employed to seal an imprinted PMMA wafer and a blank PMMA wafer. The results of microscopic cross sectional images showed dimensions of channels were well preserved during thermal bonding process. In our procedure, the deformation amount of bonding process was below 1%. The entire fabrication process may be very useful for plastic based microchip systems.

  • PDF

Micro-threads of Cross-linked Hyaluronic Acid Hydrogel using a Microfluidic Chip (미세 유체 칩 기반의 히알루론산 미세 실의 제작)

  • Lee, Yun-Kyung;Lee, Kwang-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • The successful synthesis of hyaluronic acid micro-threads is very promising approach for the broad application in tissue engineering such as dermal fillers. Because hyaluronic acid has the excellent biocompatibility and ability to maintain the moisture of up to several hundred times its own weight. In order to generate the hyaluronic acid micro-threads in microfluidic system, we employed two-phase flow microfluidic chip to make a rapid synthesis of the hyaluronic acid hydrogel. Hyaluronic acid was mixed with 0.02N NaOH solution and 1, 4-Butanediol diglycidyl ether (BDDE) solution and then injected into core channel. The ethanol was used for the 3-dimensional micro-thread formation in sheath channel. We manipulated the diameter of HA micro-threads using controlling of flow rates in microfluidic chip, and showed the feasibility of immobilization in HA micro-threads with florescent substances. Also, the generated HA micro-threads were evaluated and showed the suitable properties with tensile strength, bending property, and swelling profiles for dermal fillers. As a result, we suggested an innovative method for microfluidic chip-based HA micro-threads which could safely be applied as dermal filler in tissue engineering.

A Study on the Convective Heat Transfer in Micro Heat Exchanger Embedded in Stacked Multi-Chip Modules (적층형 Multi-Chip Module(MCM) 내부에 삽입된 초소형 열교환기 내에서의 대류 열전달 현상에 대한 연구)

  • Shin, Joong-Han;Kang, Moon-Koo;Lee, Woo-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.6
    • /
    • pp.774-782
    • /
    • 2004
  • This article presents a numerical and experimental investigation for the single-phase forced laminar convective heat transfer through arrays of micro-channels in micro heat exchangers to be used for cooling power-intensive semiconductor packages, especially the stacked multi-chip modules. In the numerical analysis, a parametric study was carried out for the parameters affecting the efficiency of heat transfer in the flow of coolants through parallel rectangular micro-channels. In the experimental study, the cooling performance of the micro heat exchanger was tested on prototypes of stacked multi-chip modules with difference channel dimensions. The simulation results and the experiment data were acceptably accordant within a wide range of design variations, suggesting the numerical procedure as a useful method for designing the cooling mechanism in stacked multi-chip packages and similar electronic applications.