• 제목/요약/키워드: Micro-movement

검색결과 217건 처리시간 0.028초

EWOD 구조에서 상유전체 BZN에 의한 micro droplet의 이동 특성 (The Movement Characteristic of Micro Droplet by BZN in EWOD structure)

  • 김나영;홍성민;박순섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.36-38
    • /
    • 2005
  • This study is about how to lower the driving voltage that enables to move the micro droplet by the EWOD (Electro Wetting On Dielectric) mechanism. EWOD is well known that it is used ${\mu}-TAS$ digital micro fluidics system. As the device which is fabricated with dielectric layer between electrode and micro droplet is applied voltage, the hydrophobic surface is changed into the hydrophilic surface by electrical property. Therefore, EWOD induces the movement of micro droplet with reducing contact angle of micro droplet. The driving voltage was depended on the dielectric constant of dielectric layer, thus it can be reduced by increase of dielectric constant. Typically, very high voltage ($100V{\sim}$) is used to move the micro droplet. In previous study, we used $Ta_{2}O_{5}$ as the dielectric layer and driving voltage was 23V that reduced 24 percent compared with $SiO_2$. In this study, we used $BZN(Bi_{2}O_{3}ZnO-Nb_{2}O_{5})$ layer which had high dielectric constant. It was operated the just 12V. And micro droplet was moved within Is on 15V. It was reduced the voltage until 35 percents compare with $Ta_{2}O_{5}$ and 50 percents compare with $SiO_2$. The movement of micro droplet within 1s was achieved with BZN (ferroelectrics)just on 15V.

  • PDF

Comparison of tooth movement and biological response in corticotomy and micro-osteoperforation in rabbits

  • Kim, Junghan;Kook, Yoon-Ah;Bayome, Mohamed;Park, Jae Hyun;Lee, Won;Choi, Hojae;Abbas, Noha H.
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.205-213
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the amount of tooth movement and histologic changes with different corticotomy designs and micro-osteoperforation in rabbits. Methods: The sample consisted of 24 rabbits divided into three experimental groups (triangular corticotomy [TC] and indentation corticotomy [IC] with flap, and flapless micro-osteoperforations [MP]) and a control. A traction force of 100 cN was applied by connecting the first premolars to the incisors. The amount of tooth movement was measured. Kruskal-Wallis test was used to assess differences in tooth movement between the groups. Micro-computed tomography, hematoxylin and eosin staining, and tartrate-resistant acidic phosphatase (TRAP) analysis were performed. Analysis of variance was applied to assess differences in TRAP-positive osteoclast count between the groups. Results: The amount of tooth movement increased by 46.5% and 32.0% in the IC and MP groups, respectively, while the bone fraction analysis showed 69.7% and 8.5% less mineralization compared to the control. There were no significant intergroup differences in the number of TRAP-positive osteoclasts. Conclusions: The micro-osteoperforation group showed no significant differences in the amount of tooth movement compared to the corticotomy groups, nor in the TRAP-positive osteoclast count compared to both corticotomy groups and control.

척추극돌간 미세움직임 재현 보형물의 개발 및 평가 (Development and Evaluation for the Micro-Movement Structure of Interspinous)

  • 박준식;서태일;배종석;윤길상
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.127-131
    • /
    • 2006
  • Existing orthopedic implants such as pedicle screw and spinal cage were designed to fix the spinal structure. But, nowadays, physicians want to rehabilitate there original functions. To achieve this request, we studied micro-movable structure for interspinous. As a first step, we designed interspinous structure by 3D CAD to join each spinous processes. Next, we simulate it with various factors such as the thickness of micro-movement structure and the design of clip. At last, we performed static compressive test to satisfy the failure load of 339N and dynamic endurance test of 1.2M cycle. As a result, we developed interspinous implant and did several surgery to evaluated its satisfaction.

친밀도, 공감도, 긍정도에 따른 얼굴 근육의 미세움직임 반응 차이 (Research on Micro-Movement Responses of Facial Muscles by Intimacy, Empathy, Valence)

  • 조지은;박상인;원명주;박민지;황민철
    • 한국콘텐츠학회논문지
    • /
    • 제17권2호
    • /
    • pp.439-448
    • /
    • 2017
  • 얼굴 표정은 상호간의 소통에 있어 중요한 의미를 갖는다. 얼굴 근육의 움직임은 감성 정보를 제공하는데, 이는 사회적 관계를 향상하는 데 중요한 역할을 한다. 그러나 얼굴의 단순 움직임만으로는 복잡한 사회 감성을 인식하기에 정확하지 않다. 본 연구의 목적은 친밀도, 공감도, 긍정도와 같은 사회감성을 인식하기 위한 얼굴의 미세 움직임을 분석하는 것이다. 76명의 피험자를 대상으로 상기 사회감성을 유발하는 자극을 제시하였고 카메라를 사용하여 얼굴 표정을 측정하였다. 결론적으로 친밀함, 공감도, 긍정도의 사회 감성에서 얼굴의 미세움직임이 다르게 나타났다. 총 44개의 얼굴 근육 중 3개의 무의식 근육과 18개의 의식 근육의 움직임 양을 추출한 후, 고속푸리에변환(Fast Fourier Tranform, FFT)을 통하여 (Dominant) Frequency 대역을 확인하였다. 독립 t-검정 결과, 친밀도 상황에서는 코 주변과 볼 주변 근육, 공감도 상황에서는 입 주변 근육, 긍정도 상황에서는 턱 주변 근육에서 유의한 차이를 보였다. 이는 애니메이션의 가상 아바타 등 얼굴 표정의 새로운 표현요소를 제안하고 근육에 따른 사회감성 인식의 기초 연구로서 활용 가능할 것으로 사료 된다.

인체 미동을 이용한 공감도 평가 방법 (Empathy Evaluation Method Using Micro-movement)

  • 황성택;박상인;원명주;황민철
    • 감성과학
    • /
    • 제20권1호
    • /
    • pp.67-74
    • /
    • 2017
  • 본 연구는 사회 감성(Social emotion)중 공감도 정량화 방법을 제안하고자 한다. 비접촉형 센싱 방법인 인체 미동 기술을 이용하였다. 참가자들은 공감한 그룹과 공감하지 않은 그룹으로 분류하였다. 웹캠(Web-cam)을 이용해 표정 Task를 수행하는 동안 영상의 상반신 데이터를 수집하였다. 수집 된 데이터는 각 주파수 성분 별로 0.5 Hz, 1 Hz, 3 Hz, 5 Hz, 15 Hz로 분류하여 추출하였다. 추출 된 데이터는 움직임의 평균과 변화량, 움직임의 동조현상을 비교하였다. 그 결과 공감한 그룹의 움직임 평균과 움직임의 변화정도가 낮게 나타났다. 공감하지 못한 그룹의 경우 평균 움직임과 변화정도가 큰 것으로 나타났으며 통계적으로 유의한 차이를 보였다. 또한 공감한 그룹의 두 피험자의 경우 표정 Task를 수행하는 동안 움직임에 동조 현상이 나타나는 것을 확인하였다. 이는 두 사람 간에 공감이 형성 되었을 때 자연스럽게 집중을 하게 되고 그에 따라 움직임에 정도가 차이가 나는 것으로 볼 수 있다. 본 연구는 비접촉 센싱 방법을 통해 공감도 측정 가능성을 확인하는데 의의가 있다.

Comparison of the effects of horizontal and vertical micro-osteoperforations on the biological response and tooth movement in rabbits

  • Kim, Seok-gon;Kook, Yoon-Ah;Lim, Hee Jin;Park, Patrick;Lee, Won;Park, Jae Hyun;Bayome, Mohamed;Kim, Yoonji
    • 대한치과교정학회지
    • /
    • 제51권5호
    • /
    • pp.304-312
    • /
    • 2021
  • Objective: This study aimed to compare the amount of tooth movement after multiple horizontal (MH) and single vertical (SV) micro-osteoperforations (MOPs), and evaluate the histological changes after orthodontic force application in rabbits. Methods: The mandibles of 24 white rabbits were subjected to two experimental interventions: MH and SV MOPs. Defect volume of the MOPs between the two groups was kept similar. A force of 100 cN was applied via a coil spring between the incisor teeth and the first premolars. The amount of tooth movement was measured. Differences in the amount of tooth movement and bone variables at three time points and between the two groups were evaluated using repeated-measures analysis of variance. Results: The first premolar showed a mesial movement of 1.47 mm in the MH group and 1.84 mm in the SV group, which was significantly different at Week 3 (p < 0.05). No significant difference was observed in bone volume and bone fraction between the groups. Tartrate-resistant acidic phosphatase-positive cell count was also significantly greater at Week 3 than at Week 1 in both the SV and MH groups. Conclusions: The amount of tooth movement showed significant differences between Weeks 1 and 3 in the SV and MH MOP groups, but showed no differences between the two groups. Therefore, SV MOP could be considered an effective tool for enhancing tooth movement, especially for molar distalization, uprighting, and protraction to an edentulous area.

자율주행 내시경을 위한 공압 구동장치의 이동특성에 관한 실험적 연구 (Experimental Study on the Movement of Pneumatic Actuating Mechanism for Self-Propelling Endoscope)

  • 임영모;박지상;김병규;박종오;김수현
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.194-199
    • /
    • 2001
  • In this paper, we propose a new locomotive mechanism using impulsive force for microcapsule-type endoscope. It has the compact size for movement in the colon and actuating mechanisms for hi-directional movement. The actuating mechanism resembles a pneumatic cylinder and consists of body, inertia mass(piston). spring. pneumatic source and calve. When valve is ON, the pneumatic impulsive force between piston and body drives them in two opposite direction. As the air in the body is passed away, the contrary movements are occurred by spring reaction. Therefore, the direction of body's motion is determined by the relative magnitude of two opposite impulsive forces, i.e., pneumatic and spring force. The effect of two impulsive forces can simply be controlled by On-Off time of solenoid valve.

  • PDF

EWOD(Electro-Wetting on Dielectric)에 의한 초소수성 표면에서의 액적 이동과 부유물의 영향 (The droplet movement on the super-hydrophobic surface by the electro-wetting on dielectric and the effect of particles)

  • 변도영;이영종
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.297-300
    • /
    • 2006
  • This article discusses about the droplet movement on the super-hydrophobic surface by the electro-wetting on dielectric and the effect of particles on the contact angle as well as the movement is investigated. The movement of droplet, driven by the principle of electro-wetting on dielectric, and the effect of particles are experimentally verified according to the driving voltage and different particles concentrations (fluorescent, charged particles). To increase the contact angle, the super-hydrophobic surface is fabricated and applied to the dielectric layer for the EWOD device. Then its performance is verified and discussed.

  • PDF

Nonlinearity를 갖는 Micro Electorstatic Actuator의 초정밀 추종제어 (High precision tracking contorl algorithm for micro electrostatic actuator with nonlinearity)

  • 김경한;최현택;송재욱;정완균
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.464-467
    • /
    • 1997
  • In this paper, a high precision track following control algorithm is proposed for micro electrostatic actuator considering of the application for hard disk drive. The micro electrostatic actuator proposed has nonlinear voltage-displacement characteristic in a working range of 0.8.mu.m and has uni-directional movement. Mid range reference and open-loop bias are proposed for the revision of negative position error, and inverse model for linearization.

  • PDF

골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석 (Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage)

  • 김찬년;성재현;경희문
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.339-350
    • /
    • 2003
  • 본 연구에서는 활주법을 이용한 전치부 후방 견인시 micro-implant의 다양한 수직적 위치와 전치부에서 힘의 적용점에 따른 치아 이동 양상을 관찰하여 공간 폐쇄시 전치부의 설측 경사와 정출력을 방지할 수 있는 micro-implant의 위치와 전치부 힘의 적용점의 위치를 알아보고자 하였다. 유한 요소 모델을 이용하여 제1소구치가 발거된 상악 치열궁 형태를 제작하고 $.022"{\times}.028"$ 슬롯 브라켓을 모형화하여 치아에 부착시켰다. $.019"{\times}.025"$ stainless steel 선재를 3차원 beam모형으로 제작하고 상악 측절치와 견치 브라켓 사이의 선재 상에 $.032"{\times}.032"$ 크기의 stainless steel hook을 수직으로 8mm의 높이로 형성하였으며, 선재로부터 2mm높이에서 1mm간격으로 8mm까지 힘 적용점을 설정하였다. 지름 1.2mm,길이 6mm의 micro-implant를 제2소구치와 제1대구치 사이의 치조골에 선재로부터 4mm에서 10mm까지 2mm간격으로 4개를 위치시켰다 각각의 micro-implant와 전치부 hook에 150gm의 힘을 적용시켜 다양한 힘 적용점에 따른 치아의 초기 변위를 분석하여 다음의 결과를 얻을 수 있었다. 1. Micro-implant 높이가 4m일 경우 5mm이하의 전치부 hook 높이에서는 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6m이상 되었을 때 전치부 순측 경사 이동이 일어났다. 2. Micro-implant높이가 6mm일 경우 5mm이하의 전치부 hook높이에서 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6mm 이상 되었을 때 전치부 순측 경사 이동이 일어났다 이것은 4mm micro-implant에서의 실험결과와 유사한 이동 양상을 나타내었지만, micro-implant높이가 6mm일 때 전치부 설측 경사 이동이 좀더 감소하였다. 3. Micro-implant높이가 8m일 경우 전치부 hook높이가 2mm일 때 전치의 설측 경사 이동이 일어났으며 3mm이상의 전치부 hook 높이에서 순측 경사 이동이 비례적으로 증가하였다. 4. Micro-implant높이가 10mm일 경우 전치부 hook 높이가 2mm 이상에서 전치의 순측 경사 이동이 비례적ㅇ로 증가하였다. 5. 전치부 hook 높이가 증가할수록 전치의 순측 경사 이동이 증가되지만 선재의 뒤틀림에 의한 변형이 증가되므로 견치와 소구치 부위에서 정출력이 발생하는 바람직하지 못한 치아 이동 양상이 일어났다. 6. Micro-implant를 이용한 상악 5전치 후방 견인시 구치부의 이동은 선재와 브라켓 사이의 마찰력에 의해서 원심경사 이동이 발생하였다.