• Title/Summary/Keyword: Microbead

Search Result 30, Processing Time 0.022 seconds

Porosity Control of Porous Zirconia Ceramics (다공질 지르코니아 세라믹스의 기공율 제어)

  • Chae, Su-Ho;Eom, Jung-Hye;Kim, Young-Wook;Song, In-Hyuek;Kim, Hai-Doo;Bae, Ji-Soo;Na, Sang-Moon;Kim, Seung-Il
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.1
    • /
    • pp.65-68
    • /
    • 2008
  • A simple pressing process using zirconia and microbead for fabricating porous zirconia ceramics is demonstrated. Effects of microbead content and sintering temperature on microstructure, porosity, compressive and flexural strengths were investigated in the processing of porous zirconia ceramics using microbead as a pore former. By controlling the microbead content and the sintering temperature, it was possible to produce porous zirconia ceramics with porosities ranging from 43% to 70%. Typical compressive and flexural strength values at ${\sim}50%$ porosity were ${\sim}150\;MPa$ and ${\sim}35\;MPa$, respectively.

Microbead-based bio-assay using quantum dot fluorescence in a microfluidic chip (미소유체 칩 상에서 Quantum Dot 및 마이크로 비드를 이용한 생체물질 분석)

  • Yun, Kwang-Seok;Lee, Do-Hoon;Kim, Hak-Sung;Yoon, Eui-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.308-312
    • /
    • 2005
  • We present a microfluidic chip designed for the detection of antibody by using quantum dots fluorescence and a microbead-based assay. A custom designed PDMS microfluidic chip with multi-layer channel is utilized for capturing microbeads; antibody injection into each micro-well; QD injection; and fluorescence detection. The experiment using the fabricated microfluidic chip has been performed on solutions with various concentrations of antibody and has shown correlated fluorescent intensities.

Comparison of Skin Condition Before and After Use of Scrub Cosmetics and Microscopic Characteristics of Microbeads (스크럽 화장품의 사용 전과 후의 피부상태 비교와 이에 첨가된 마이크로비드의 현미경적 특성)

  • Kim, Hoon;Chang, Byung-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.6
    • /
    • pp.211-217
    • /
    • 2019
  • In this study, the change of skin condition was analyzed by skin analysis equipment using scrub cosmetics, and the morphological characteristics of microbead were observed by dermascope and scanning electron microscope. In the dermascope observation, during the process of cleansing, the microbeads attached to the skin existed in close contact with each other or dispersed. The skin after scrubbing was clean and smooth and the fine wrinkles between epidermal keratinocytes were reduced. In the scanning electron microscopic observation, the microbead surface did not have severe bending or rough surface. The skin moisture and oil content were higher than the scrub skin before the scrub, and there was no significant difference in the pH.

Fabrication of Biochip Using Gray-scale Photolithography (Gray-scale photolithography를 이용한 바이오칩 제작)

  • Bae, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.137-141
    • /
    • 2008
  • Biochip, which implements bioanalytical process on a tiny surface, is one of candidates for medical diagnosis, drug screening, and molecular sensing. In general, a type of biochip based on microfluidics is composed of microcomponents including microchannel, pump, and valve, which require complicated processes. In this study, gray-scale photolithography(GSPL) was applied to fabricate a biochip with multiple layers. A mould for casting PDMS(polydimethylsiloxane) channel, was fabricated using GSPL. A gray-photomask was prepared by printing gray patterns on a high-quality glossy paper followed by photoreducing by 10:1 onto the photo-film. The formation of multiple layers was studied according to the change of gray level of pattern and the developing time. A biochip composed of a weir(multiple layer structure) and a reaction chamber in a single microchannel was fabricated in a glass plate. Finally, we investigated the application of biochip to antigen-antibody reaction by packing the microbead coated with antibody.

Effect of pH on Swelling Property of Hyaluronic Acid Hydrogels for Smart Drug Delivery Systems

  • Kim, Jin-Tae;Lee, Deuk-Yong;Kim, Young-Hun;Lee, In-Kyu;Song, Yo-Seung
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.256-262
    • /
    • 2012
  • Hyaluronic acid(HA) hydrogels were synthesized by immersing HA microbeads in phosphate buffered saline solutions having different pH levels to assess the effect of pH on the swelling ratio of HA hydrogels for smart drug delivery systems. No beads were formed when the HA solution(below pH 9) was crosslinked with divinyl sulfone(DVS) because DVS is a basic solution. The variation regarding the size of the microbead was not significant, suggesting that the bead size is not a function of pH(10 ~ 14). However, the pore size of the microbeads decreased with increasing pH from 10 to 14, leading to the surface smoothness and dense network as a result of higher crosslinking. The swelling ratio of hydrogels increased when the pH rose from 2(acidic) to 6(neutral). Afterwards, it decreased with further increasing pH(basic). The lower swelling ratio may be due to the lack of ionization of the carboxyl groups. On the other hand, a higher swelling ratio is likely due to the increased electrostatic repulsions between negatively charged carboxyl groups on different chains. Experimental results suggested that pH-responsive HA hydrogels can be applicable to the controlled drug delivery systems.

The Synthesis and Characterization of Mesoporous Microbead Incorporated with CdSe/ZnS QDs (양자점이 고밀도화된 마이크로 비드의 제조 및 특성)

  • Lee, Ji-Hye;Hyun, Sang-Il;Lee, Jong-Huen;Koo, Eun-Hae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.8
    • /
    • pp.657-663
    • /
    • 2012
  • The spherical mesoporous silica is synthesized and incorporated with CdSe/ZnS quantum dots(QDs) for preparing micro beads to detect toxic and bio-materials with high sensitivity. The spherical silica beads with the brunauer-emmett-telle(BET) average pore size of 15 nm were prepared with a ratio 1, 3, 5-trimethylbenzen, as a swelling agent, to the block-copolymer template surfactant of over 1 and under vigorous mixing condition. The surface of spherical mesoporous silica is modified using octadecylsilane for incorporating QDs. Based on photoluminescence(PL) spectra, the relative brightness of mesoporous silica beads incorporated with 10 nM of QDs is 79,000 times brighter than that of Rodamine 6 G.

Characterization of Cross Linked Hyaluronic Acid Microbeads by Divinyl Sulfone (Divinyl Sulfone으로 가교된 히알루론산 마이크로비드의 특성평가)

  • Kim, Jin-Tae;Lee, Deuk Yong;Jang, Ju-Woong;Kim, Tae-Hyung;Jang, Yong-Wun
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.117-122
    • /
    • 2013
  • Hyaluronic acid(HA) microbeads were synthesized by dropping the sodium hyaluronate(Streptococcus) solutions in NaOH into a solution mixture of divinyl sulfone(DVS) in 2-methyl-1-propanol, followed by stirring, cleaning and drying process at room temperature. The initial experimental conditions are crosslinking time(CLTi) of 5 h, crosslinking temperature(CLTe) of room temperature, injection air pressure(IAPr) of 5 psi, and DVS concentration( DVSc) of 0.2 vol%, respectively. Then, parametric studies were performed by varying the parameters to investigate the morphology, the porosity, the swelling ratio and the size of the beads. The microbead size pattern was not regular to function of the degree of crosslink. It was observed that the swelling ratio, the degree of crosslink, and the pore size can be controlled by adjusting the CLTi, CLTe and DVSc. Among the parameters investigated, the smallest bead size can be achieved by varying the CLTi parameter. The lowest swelling ratio, as an indication of the highest degree of crosslink, can be obtained by varying CLTe.

Low Temperature Processing and Properties of Porous Frit-Bonded SiC Ceramics (프릿을 이용한 다공질 SiC 세라믹스의 저온 제조 공정 및 물성)

  • Chae, Su-Ho;Kim, Young-Wook;Song, In-Hyuck;Kim, Hai-Doo;Bae, Ji-Soo;Na, Sang-Moon;Kim, Seung-Il
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.5
    • /
    • pp.488-492
    • /
    • 2009
  • Porous frit-bonded SiC ceramics were successfully prepared at a temperature as low as $800^{\circ}C$ from SiC, frit, and microbeads (glass or polymer). The effects of SiC starting particle size and microbead addition on microstructure, porosity, and flexural strength were investigated. The addition of hollow glass microbead improved the strength of frit-bonded SiC ceramics without the loss of porosity by acting additional binder phase between SiC grains. The 65 ${\mu}m$-sized SiC resulted in lower porosity and higher strength than 50 ${\mu}m$-sized SiC because of higher packing density. Typical flexural strengths of frit-bonded SiC were 23 MPa at 46% porosity and 19 MPa at 49% porosity.

Microfluidic Immuno-Sensor Chip using Electrical Detection System (전기 검출 시스템을 이용한 Microfluidic Immuno-Sensor Chip)

  • Maeng, Joon-Ho;Lee, Byung-Chul;Cho, Chul-Ho;Ko, Yong-Jun;Ahn, Yoo-Min;Cho, Nahm-Gyoo;Lee, Seoung-Hwan;Hwang, Seung-Yong
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.325-330
    • /
    • 2006
  • This study presents the characterization of an integrated portable microfluidic electrical detection system for fast and low volume immunoassay using polystyrene microbead, which are used as immobilization surfaces. In our chip, a filtration method using the microbead was adopted for sample immobilization and immunogold silver staining(IGSS) was used to increase the electrical signal. The chip is composed of an inexpensive and biocompatible Polydimethylsiloxane(PDMS) layer and Pyrex glass substrate. Platinum microelectrodes for electric signal detection were fabricated on the substrate and microchannel and pillar-type microfilters were formed in the PDMS layer. With a fabricated chip, we reacted antigen and antibody according to the procedures. Then, silver enhancer was injected to increase the size of nanogold particles tagged with the second antibody. As a result, microbeads were connected to each other and formed an electrical bridge between microelectrodes. Resistance measured through the electrodes showed a difference of two orders of magnitude between specific and nonspecific immuno-reactions. The detection limit was 10 ng/ml. The developed immunoassay chip reduced the total analysis time from 3 hours to 50 min. Fast and low-volume biochemical analysis has been successfully achieved with the developed microfilter and immuno-sensor chip, which is integrated to the microfluidic system.

Immobilization of an Enzyme with Chitosan Microbeads (Chitosan Microbeads에 의한 효소고정화)

  • SOHN Heung-Sik;PARK Seong-Min;SON Byung-Yil;CHOI Hyeon-Mee;LEE Keun-Tai
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.1
    • /
    • pp.83-87
    • /
    • 1999
  • Immobilization of amyloglucosidase (AMG) with chitosan microbead and its possible applications were evaluated. The diameter of chitosan inicrobead was about 1.2 mm and the optimum enzyme concentration for immobilization was 6 mg/ml. The relative activity of the immobilized enzyme was $97.8\%$ at pH 4.2 and $55^{\circ}C$ and the optimum condition for the immobilized enwme was the same to that of free enzyme. In case of temperature above $30^{\circ}C$, the activity of the immobilized enzyme was a little higher than that of free enzyme. The enzyme activities of both free and immobilized were stable for 6 months when stored at $35^{\circ}C$. The optimum temperatures of both enzymes for saccharification of the dextrinized starch were $55^{\circ}C$ while the relative activity of the immobilized enzlme was $62.6\%$.

  • PDF