Enhanced Virus Removal by Flocculation and Microfiltration

  • Han Binbing;Carlson Jonathan O.;Powers Scott M.;Wickramasinghe S. Ranil
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권1호
    • /
    • pp.6-9
    • /
    • 2002
  • In this work we have investigated the feasibility of virus clearance by flocculation and tangential flow microfiltration. Chinese hamster ovary cell feed streams were spiked with minute virus of mice and then flocculated using cationic polyelectrolytes prior to tangential flow microfiltration. Our results indicate that flocculation prior to microfiltration leads to more than 100 fold clearance of minute virus of mice particles in the permeate. Today, validation of virus clearance is a major concern in the manufacture of biopharmaceutical products. Frequently new unit operations are added simply to validate virus clearance thus increasing the manufacturing cost. The results obtained here suggest that virus clearance can be obtained during tangential flow microfiltration. Since tangential flow microfiltration is frequently used for bioreactor harvesting this could be a low cost method to validate virus clearance.

Modelling of starch industry wastewater microfiltration parameters by neural network

  • Jokic, Aleksandar I.;Seres, Laslo L.;Milovic, Nemanja R.;Seres, Zita I.;Maravic, Nikola R.;Saranovic, Zana;Dokic, Ljubica P.
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.115-121
    • /
    • 2018
  • Artificial neural network (ANN) simulation is used to predict the dynamic change of permeate flux during wheat starch industry wastewater microfiltration with and without static turbulence promoter. The experimental program spans range of a sedimentation times from 2 to 4 h, for feed flow rates 50 to 150 L/h, at transmembrane pressures covering the range of $1{\times}10^5$ to $3{\times}10^5Pa$. ANN predictions of the wastewater microfiltration are compared with experimental results obtained using two different set of microfiltration experiments, with and without static turbulence promoter. The effects of the training algorithm, neural network architectures on the ANN performance are discussed. For the most of the cases considered, the ANN proved to be an adequate interpolation tool, where an excellent prediction was obtained using automated Bayesian regularization as training algorithm. The optimal ANN architecture was determined as 4-10-1 with hyperbolic tangent sigmoid transfer function transfer function for hidden and output layers. The error distributions of data revealed that experimental results are in very good agreement with computed ones with only 2% data points had absolute relative error greater than 20% for the microfiltration without static turbulence promoter whereas for the microfiltration with static turbulence promoter it was 1%. The contribution of filtration time variable to flux values provided by ANNs was determined in an important level at the range of 52-66% due to increased membrane fouling by the time. In the case of microfiltration with static turbulence promoter, relative importance of transmembrane pressure and feed flow rate increased for about 30%.

Purification During Crossflow Electromicrofiltration of Fermentation Broth

  • Park Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.500-505
    • /
    • 2004
  • The present study was to investigate the purification of a fermentation broth by an electromicrofiltration membrane. Microfiltration runs with a crude and a centrifuged broth, with solution of particles recovered from centrifugation and with permeates from microfiltration experiments were thus compared. Microfiltration performances were governed by colloids and small particles that induced sharp initial flux declines. For these results, the evolution of the overall membrane resistance was increased by $80\%$ in comparison with the electromicrofiltration membrane. The main focus of this study was set on the enhancement of the filtrate flux by an electric field. This pressure electrofiltration leads to a drastic improvement of the filtration by $100\%$ and the filtration time was thereby reduced. Pressure electrofiltration serves as an inter­esting alternative to the cross-flow filtration and it effectively separates advantageous constitu­ents such as amino acids and biopolymers from a fermentation broth. They were equally main­tained during the microelectrofiltration, although they were significantly reduced by $45\%$ by the microfiltration without the application of an electric field. Accordingly, since the electrofiltration membrane was provided more permeability, this study experimentally demonstrates that the permeability inside a membrane can be controlled using an electric field.

활성탄과 Membrane을 이용한 수처리효과에 관한연구 (A Study on The Effectiveness of Watertreatment Using Activated Carbons and Membranes)

  • 김영진;김영규;정문호
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.67-72
    • /
    • 1997
  • To evaluate the effectiveness of water treatment using nanofiltration, ultrafiltration, and microfiltration systems, tapwater contaminated by bacteria and nitrate nitrogen was filtered, and then the rates of removal for many kinds of contaminants were comp.ared and investigated. The rates of turbidity removal by these systems are around 80% all of them. However, nanofiltration system is the most effective as hardness removal is 80%, suspended solids 90%, total residual chlorine 90% and nitrate nitrogen 69%. Among nanofiltration, ultrafiltration and microfiltration systems, nanofiltration system is the most stable in flow rate of permeate. Comparing hollow and spiral type of ultrafiltration, microfiltration each, spiral type is more stable than hollow type owing to rinsing effect of brine. The values of pH in ultrafiltration and microfiltration systems are between 7, 0 and 7.5, and that of nanofiltration system is low to 6.2-7.0. The effectiveness of heterotrophic bacteria removal is the most excellent in the nanofiltration system.

  • PDF

Biofilter pretreatment for the control of microfiltration membrane fouling

  • Park, Jae-Hyung;Satoshi Takizawa;Hiroyuki Katayama;Shinichiro Ohgaki
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 춘계 총회 및 학술발표회
    • /
    • pp.31-38
    • /
    • 2003
  • A pilot scale biofilter pretreatment-microfiltration system (BF-MF) was operated to investigate the effect of biofilter treatment in fouling reduction of microfiltration. Biofiltration was expected to reduce the membrane fouling by removal of turbidity and metal oxides. The hollow-fiber MF module with a nominal pore size of 0.1$\mu$m and a surface area of 8m$^2$ was submerged in a filtration tank and microfiltration was operated at a constant flux of 0.5 m/d. Biofiltration using polypropylene pellets was performed at a high filtration velocity of 320 m/d. Two experimental setups composed of MF and BF/MF, i.e., without and with biofilter pretreatment, were compared. Throughout the experimental period of 9 months, biofilter pretreatment was effective to reduce the membrane fouling, which was proved by the result of time variations of trans-membrane pressure and backwash conditions. The turbidity removal rate by biofiltration varied between 40% to 80% due to the periodic washing for biofilter contactor and raw water turbidity. In addition to turbidity, metals, especially Mn, Fe and Al were removed effectively with average removal rates of 89.2%, 67.8% and 64.9%, respectively. Further analysis of foulants on the used membranes revealed that turbidity and metal removal by biofiltration was the major effect of biofiltration pretreatment against microfiltration fouling.

  • PDF

응집과 막여과 공정에서 응집제에 따른 유기물 및 THMFP제거 (Removal of natural organic matter and trihalomethane formation potential by four different coagulants during coagulation-microfiltration processes)

  • 박근영;최양훈;진용철;강선구;권지향
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.101-112
    • /
    • 2013
  • Integrated process with coagulation and microfiltration as an advanced water treatment has been expanded its application in recent years due to its superb removal of particles and natural organic matter. In usual, effectiveness of coagulation sometimes determines performance of the whole system. Several new polymeric coagulants introduced to water utilities for better efficiency were studied in this paper. Three polymeric coagulants (i.e., PACl, PACs, and PAHCs) along with alum were evaluated for removal of natural organic matter, especially for reduction of trihalomethane formation potential, for which regulation has become stringent. Turbidity removal was closely related to pH variation showing the reduced turbidity removal by PACs due to the decreases in the pH of supernants at high doses. The four coagulants showed different organic matter removal during coagulation and affected the removal in microfiltration. For instance, DOC concentration was not reduced by microfiltration when PAHCs were used however 10 % of DOC removal was observed by microfiltration with alum coagulation. Coagulation pretreatment also impacted the THM removals, i.e., approximately 30 % of THMs and 13 % of DOC was removed by microfiltration only, but 40 to 67 % of THMs and 30 % of DOC was removed by the integrated process. Strategies on selection of coagulants are needed depending on characteristics of target pollutants in raw waters.

광촉매 및 알루미나 정밀여과 혼성공정에 의한 고탁도 원수의 고도정수처리: 질소 역세척시 유기물의 영향 (Advanced Water Treatment of High Turbidity Source by Hybrid Process of Photocatalyst and Alumina Microfiltration: Effect of Organic Matters at Nitrogen Back-flushing)

  • 박진용;심성보
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.441-449
    • /
    • 2012
  • 정수처리용 알루미나 정밀여과 및 광촉매의 혼성공정에서 주기적 질소 역세척 시 휴믹산 농도의 영향을 알아보고, 막오염에 의한 저항 ($R_f$) 및 투과선속 (J), 총여과부피 ($V_T$) 측면에서 정밀여과의 물 역세척 또는 한외여과의 질소 역세척한 기존 결과와 비교 고찰하였다. 그 결과, 휴믹산 농도의 영향으로 막오염이 진행되는 경향은 질소 또는 물 역세척에 따라, 동일한 재질이라도 한외여과 또는 정밀여과에 따라 차이를 보였다. 또한 동일한 재질의 분리막의 경우 한외여과 보다 정밀여과에서 질소 역세척이 막오염 억제에 효과적이고, 동일한 정밀여과인 경우 물 역세척보다 질소 역세척이 효과적이었다. 탁도 처리효율은 휴믹산 농도와 무관하게 거의 일정하였으나, 휴믹산 처리효율은 휴믹산 10 mg/L에서 최대였다. 이러한 결과로부터 정밀여과막의 질소 역세척시 휴믹산의 농도가 증가할수록 처리수의 휴믹산 농도도 높아지지만, 휴믹산 농도 10 mg/L에서 광촉매 구의 흡착과 광산화로 휴믹산이 최대 효율로 제거된다는 것을 알 수 있었다.

하수를 공업용수로 재이용하기 위한 정밀여과 및 역삼투 시스템 적용에 관한 연구 (Application of Microfiltration and Reverse Osmosis System to Sewage Reuse for Industrial Water)

  • 강신경;이해군;김지원
    • 멤브레인
    • /
    • 제12권3호
    • /
    • pp.151-157
    • /
    • 2002
  • 본 연구는 하수를 공업용수로 재이용하기 위한 분리막 시스템 적용에 관한 연구이다. 정밀여과와 역삼투시스템으로 구성된 bench scale 실험장치를 이용하여 하수처리장 현장에서 실험을 수행한 결과, 정밀여과 시스템은 이온성분은 제거할 수 없었으나 SS를 70% 이상 처리할 수 있어 처리수는 직접냉각수로 재이용이 가능하였다. 그리고 역삼투 시스템은 SS는 물론 이온성분도 95% 이상 제거할 수 있어 처리수는 간접냉각수 및 제품세척수로 사용이 가능하였다. $100 m^3$/일 용량의 pilot Plant를 제작하기 위해서는 정밀여과 모듈은 20개, 역삼투 모듈은 12개가 필요하였다.

정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구 (A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process)

  • 국영롱;주재영;배윤선;이혜인;정인호;박철휘
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

Effect of High-Temperature Spinning and PVP Additive on the Properties of PVDF Hollow Fiber Membranes for Microfiltration

  • Cha, Bong-Jun;Yang, Jung-Mok
    • Macromolecular Research
    • /
    • 제14권6호
    • /
    • pp.596-602
    • /
    • 2006
  • The effect of high-temperature spinning and poly(vinyl pyrrolidone) (PVP) additive on poly(vinylidene fluoride) (PVDF) hollow fiber membranes was investigated using differential scanning calorimetry, X-ray diffraction measurement, and scanning electron microscopy, together with the corresponding microfiltration performances such as water flux, rejection rate, and elongational strength. Using high-temperature spinning, porous hollow fiber membranes with particulate morphology were prepared through PVDF crystallization. The particulate structure of the membranes was further modified by the addition of miscible PVP with PVDF. Due to these effects, the rejection rate and strength of the fibers were increased at the expense of reduced water flux and mean pore size, which indicates that high-temperature spinning and PVP addition are vary effective to control the morphology of PVDF hollow fiber membranes for microfiltration.