• Title/Summary/Keyword: Microfiltration

Search Result 327, Processing Time 0.026 seconds

Removal of cesium(137Cs) and iodide(127I) by microfiltration·nanofiltration·reverese osmosis membranes (정밀여과·나노여과·역삼투 막에 의한 세슘과 요오드의 제거)

  • Chae, Seon-Ha;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.549-554
    • /
    • 2014
  • This study was evaluated the applicability of the membrane filtration process (Micro Filtration (MF), nanofiltration membranes (NF), reverse osmosis (RO)) on the major radioactive substances, iodine ($I^-$) and cesium ($Cs^+$) using membranes produced in Korea and domestic raw water. Iodine ($I^-$) or cesium ($Cs^+$) in the microfiltration membrane (MF) process could not be expected removal efficiency by eliminating marginally at the combined state with colloidal and turbidity material. At the domestic raw water (lake water, turbidity 1.2 NTU, DOC 1.3 mg/L) conditions, nanofiltration membrane (NF) and reverse osmosis (RO) showed a high removal rate of about 88 ~ 99% for iodine ($I^-$) and cesium ($Cs^+$) and likely to be an alternative process for the removal of radioactive material.

Impact of Characteristics of Polymeric Al Coagulants PACl and Alum on Membrane Flux and Fouling of Microfiltration (PACl 및 Alum 응집제 특성이 정밀여과막 투과수량 및 막오염에 미치는 영향)

  • Jin, Yong-Chul;Choi, Yang-Hun;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.231-240
    • /
    • 2011
  • The objectives of this research are to investigate coagulation efficiencies of two coagulants l.e., alum and polyaluminum chloride and to understand effects of the coagulants on membrane fouling in microfiltration. The turbidity of supernatant from alum coagulation was increased with increasing doses whereas the turbidity from PACl coagulation was maintained at the low values. The observed injection volume of PACl for the same removal was approximately 30 percent less than alum, which produced a low sludge volume. The settling velocity of PACl flocs was greater than alum flocs. The results corresponded well with floc size measurements. Flux decline from alum coagulation was significant due in part to small sizes of flocs. At the low dose, alum floc had less specific cake resistance than PACl floc. However, as the dosage was increased, the increases in specific cake resistances of alum was substantial. Alum coagulation pretreatment needs careful operation to reduce membrane fouling by flocs. In general, PACl coagulants were more effective than alum coagulants for pretreatment of membrane processes because PACl showed the better performance in coagulation and membrane fouling.

Feasibility of a two step microfiltration and reverse osmosis membrane system for reuse of tunnel wastewater (터널폐수 재이용을 위한 통합형 멤브레인 시스템의 적용)

  • Lee, Jae-Hyun;Jeong, Se-Uk;Kim, Young Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.779-785
    • /
    • 2013
  • This study investigated the applicability of a two step microfiltration(MF) and reverse osmosis(RO) membrane system for reuse of tunnel wastewater. In this two step process, the MF system first treated only micropollutants in tunnel wastewater such as suspended solids(SS) and heavy metals, achieving less than 0.2 NTU turbidity, less than 1.1 mg/L chemical oxygen demand($COD_{Mn}$) and less than 0.8 mg/L total manganese(Mn). The RO system then removed over 95 % of the remaining pollutnats and particles, resulting in less than 0.02 NTU turbidity, less than 0.5 mg/L chemical oxygen demand($COD_{Mn}$), less than 0.04 mg/L total nitrogen(T-N) and less than 0.01 mg/L total phosphorus(T-P). In particular, addition of an RO system could lead to markedly reduced high salt concentrations in tunnel wastewater, approaching almost zero. Thus, reclaimed water using the combined membrane system could satisfy current South Korean regulations concerning wastewater reuse(turbidity ${\leq}2.0$ NTU; T-N ${\leq}10mg/L$; T-P ${\leq}0.5mg/L$; Salinity ${\leq}250mg{\cdot}Cl/L$).

Effects of Characteristics of Flocculent Aggregates on Membrane Fouling in Microfiltration with Coagulation Pretreatment (전처리로 응집공정을 이용한 정밀여과 공정에서 응집 플록 특성에 따른 막오염 연구)

  • Lee, Seockheon;Kweon, Ji Hyang;Choi, Yang Hun;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.785-793
    • /
    • 2004
  • Coagulation has been investigated for pretreatment of low-pressure membrane systems such as microfiltration and ultrafiltration. Coagulation pretreatment can reduce foulants (particles and organic matter) prior to membrane filtration. However, when in-line coagulation or submerged type of filtration is used, flocculent aggregates could act as a foulant depending on concentrations and specific properties of floc. A natural water and three synthetic waters were used to investigate effects of coagulation pretreatment and presence of flocculent aggregates on membrane fouling. Coagulation pretreatment shows that foul ants were effectively removed during coagulation and the formed cake layer on the membrane surface had less resistances compared to raw natural water. In addition, little difference in membrane fouling was found by flocculent aggregates from the natural water. Interestingly, however, the results by three synthetic waters indicated that flocculent aggregates could have adverse effects on membrane fouling in a specific condition.

Cake Reduction Mechanism in Coagulation-Crossflow Microfiltration Process (Crossflow 방식 응집-정밀여과 공정의 케이크층 저감 메커니즘)

  • Kim, Suhan;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.519-527
    • /
    • 2003
  • Cake layer in crossflow microfiltration(CFMF) can be reduced by coagulation, enhancing membrane flux. This is because enlarging particle size by coagulation increases shear-induced diffusivity and the back-transport of rejected particles. However it is known that the enlarged particles are disaggregated by the shear force of the pump while passing through it. This study is to look at the disaggregation in relation with cake layer reducation. Kaolin and polysulfon hollow fiber microfilter are used for experiment. The reduction of cake resistance by coagulation is observed in a range of 17% to 53% at the various coagulation conditions. The particle size analysis results of the experiments show that aggregated particles in feed are completely disaggregated by pump but re-aggregation of particles occurs in membrane. This suggestes that the re-aggregation of particles is critical to cake reduction and flux enhancement, since the aggregated particles are completely broken. The mechanisms for re-aggregation in membrane are the same with those for coagulation in feed tank. Charge neutralization is better for CCFMF than sweep flocculation although it has two drawbacks in operation.

Permeation Behavior of Microfiltration Membrane by Alumina Colloidal Suspension under a Cyclic Variation in TMP (운전압력의 순환변화에 따른 알루미나 현탁액의 정밀여과 투과거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.13-21
    • /
    • 2011
  • This study investigated the fouling behavior of $Al_2O_3$ colloids on polyethylene microfiltration membrane. To examine the effect of operation variation on fouling, operating pressure was increased from 0.49 to 1.96 bar along with time elapses and then was reduced to 0.49 bar reversely. A hysteresis behavior was observed in the membrane permeate flux over pressure, revealing different fluxes at the same pressure according to the pressure control type, increasing and decreasing. Permeate resistance and its rate of increase was higher in the decreasing pressure cycle than in the increasing pressure cycle. At the initial period of filtration, fouling mechanism for the both cycles was governed by the cake filtration. The degree of fouling was higher in the decreasing pressure cycle compared with in the increasing pressure cycle.

Fluoride removal using Alum & PACl in batch & continuous mode with subsequent microfiltration

  • Dubey, Swati;Agarwal, Madhu;Gupta, A.B.
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.83-93
    • /
    • 2021
  • In this study, defluoridation efficiency by aluminium sulphate (alum) and polyaluminium chloride (PACl) were compared for recommended Nalgonda dose (100%) and 80% of this dose in both batch and continuous modes. The residual turbidity was found to be higher in case of alum as compared to PACl with 80% dose representing lesser efficient settling of suspensions, which primarily comprise alumino-fluoro complexes that result in high residual aluminium in the treated water and this was confirmed by TEM and Zeta analysis. Moreover, the application of PACl also resulted in much lesser addition to the TDS and also required lesser lime for pH compensation due to its lower acidity. Hence this reduced dose was recommended for defluoridation. It was also observed that in case of alum, residual aluminium in treated water was 0.88 mg/L (100% dose) & 0.72 mg/L (80% dose) and in case of PACl, it was 0.52 mg/L(100% dose) & 0.41 mg/L(80% dose). After subsequent microfiltration, residual aluminium was 0.28 & 0.21 mg/L for 100% & 80% dose respectively and in case of alum and in case of PACl, it was 0.16 & 0.11 for 100% & 80% dose respectively, which conform to the Al standards(<0.2 mg/L).

Clay adsorptive membranes for chromium removal from water

  • Kashaninia, Fatemeh;Rezaie, Hamid Reza;Sarpoolaky, Hossein
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.259-264
    • /
    • 2019
  • Cost effective clay adsorptive microfiltration membranes were synthesized to remove Cr (III) from high polluted water. Raw and calcined bentonite were mixed in order to decrease the shrinkage and also increase the porosity; then, 20 wt% of carbonate was added and the samples, named B (without carbonate) and B-Ca20 (with 20 wt% calcium carbonate) were uniaxially pressed and after sufficient drying, fired at $1100^{\circ}C$ for 3 hours. Then, physical and mechanical properties of the samples, their phase analyses and microstructure and also their ability for Cr(III) removal from high polluted water (including 1000 ppm Cr (III) ions) were studied. Results showed that the addition of calcium carbonate lead the porosity to increase to 33.5% while contrary to organic pore formers like starch, due to the formation of wollastonite, the mechanical strength not only didn't collapse but also improved to 36.77 MPa. Besides, sample B-Ca20, due to the presence of wollastonite and anorthite, could remove 99.97% of Cr (III) ions. Hence, a very economic and cost effective combination of membrane filtration and adsorption technology was achieved for water treatment which made microfiltration membranes act even better than nanofiltration ones without using any adsorptive nano particles.

Characteristic of alumina-based microfiltration ceramic membrane

  • Hyunsoo, Kim;Oyunbileg, Purev;Eunji, Myung;Kanghee, Cho;Nagchoul, Choi
    • Membrane and Water Treatment
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2023
  • This work addresses the development of microfiltration ceramic membrane from alumina using extrusion method. The membranes were sintered at different temperatures ranging between 1000 and 1300℃. The alumina was characterized with thermogravimetric analysis, particle size distribution, X-ray diffraction, Fourier transform infrared spectrometer and scanning electron microscope analysis. Subsequently, the effect of sintering temperature on the membrane properties such as porosity, flexural strength, and pure water permeability was investigated and optimized for the sintering temperature. It is observed that with increasing sintering temperature, the porosity of the membranes decreases and the flexural strength, and pure water permeability of the membranes increase. The uncoated and coated membranes were compared at constant flux mode of filtration. Under the turbidity solution recirculation alone at 100 NTU, trans-membrane pressure (TMP) of uncoated membrane remained constant when the filtration flux was below 121 Lm-2 h -1 , while the coated membrane was 111 Lm-2 h -1 . Although suction pressure increased more rapidly at higher turbidity, coated membrane filtration showed better removal efficiency of the turbidity.

Clarification of Korean Tangerine Juice Using Microfiltration Membrane Process (미세여과 공정을 이용한 제주산 감귤 주스의 청징화)

  • Lee, Eun-Young;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.448-457
    • /
    • 1999
  • Citrus fruits are consumed worldwide due to their unique flavor and nutrition value. It is necessary to remove the haze material as well as to minimize the loss of major compounds such as organic acids, sugars, and ascorbic acid in membrane processes for clarification of juice. The objective of our research was to select the best membrane among one surface filter (Whatman No.4) and five microfiltration filters (GF/A, GF/D, GF/F, Gelman, and SM). Tangerine fresh blended with three times of water was partially clarified with 170 mesh followed by prefiltration in a Samduck filtration system. The best membrane was selected by measuring the amounts of major compounds in the permeates as well as the flux which were statistically analyzed with SAS program. The foulants on the membrane surface were observed by SEM. The flux of GF/A and GF/F decreased with time at probability 0.10. Gelman, SM, and GF/D maintained the stable flux. Gelman showed the highest total scores including nutritive value (the amounts of citrate, malate, and ascorbic acid) and purchasing need (brix and color). Therefore, the microfiltration membrane process was a very effective method in tangerine juice clarification and Gelman type A/E was proved to be the best membrane among the five microfiltration membranes.

  • PDF