• Title/Summary/Keyword: Mineral Oil

Search Result 521, Processing Time 0.033 seconds

Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers (배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석)

  • An, Jung-Sik;Choi, Sun-Ho;Bang, Jeong-Ju;Jung, Joong-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

Analysis on the Temperature Distribution Characteristics of Insulating oil of Transformer Using the Vegetable oil and Mineral oil (식물성 절연유와 광유가 사용된 유입변압기의 온도분포 특성)

  • An, Jung-Sik;Shim, Meoung-Seop;Jung, Joong-Il;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1215_1216
    • /
    • 2009
  • Most transformer use insulating and cooling fluids derived from petroleum crude oil, but mineral oil is some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Three transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Temperature of vegetable oil transformers was similar to temperature of mineral oil transformer in the same design at 80% load and above.

  • PDF

Analysis on the Chemical and Electrical Characteristic of Vegetable oil by Accelerated Aging (가속열화에 따른 식물성절연유의 화학적.전기적 특성 분석)

  • Choi, Sun-Ho;Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.984-989
    • /
    • 2011
  • Electrical insulation is one of the most important part in a high voltage apparatus. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. Accelerated aging transformer insulating material in vegetable oil was compared to that of mineral oil. Accelerated aging oil samples produced in the oven at $140^{\circ}C$ for 500, 1000, 1500, 2000hours. And Real transformer insulation oils samples of vegetable oil and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. Samples were analyzed at 42, 63, 93, 143, 190, 240, 300 cycles. The mineral and vegetable insulating oils were investigated for breakdown voltage, water content, total acid number, viscosity, volume resistivity, insulating paper and oil permittivity, and dissolved gas analyses. The breakdown voltage of the vegetable insulating oil is higher than that found for the mineral oil; the accelerated aging progress decreased the breakdown voltage. The vegetable oil had a higher water saturation than the mineral oil; the vegetable oil has the superior water characteristics and breakdown voltage. And high viscosity of vegetable oil, care has to be taken, especially when designing the cooling system for a large transformer.

Research of Accelerated Aging According to Long-term Stability of Vegetable Oil (식물성절연유의 가속열화에 따른 장기적 안정성 분석)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1148-1152
    • /
    • 2012
  • The vegetable-based insulating oils are substitutes for mineral oils in oil-filled transformer. The important properties of vegetable insulating oil is their higher flash/fire point and biodegradability than conventional mineral oils. The large oil-filled transformer eliminate the risk of explosion and fire should the transformer fail and oil ignite owing to high flash/fire point of vegetable insulating oil. In addition, higher biodegradability of vegetable insulating oils can let the oil spill damage reduced. In this experiment, the real oil-filled transformers using mineral oil and vegetable oil have accelerated aging. After working on the 100% accelerated aging experiment were conducted comparing the transformer. The hottest-spot temperature using thermal coefficients were calculated to determin the degree of accelerated aging. As a result, apply mineral oil transformer in accordance with the accelerated aging life come to an end. In contrast, vegetable insulating oils showed the opposite characteristics. Vegetable insulating oil compared to the mineral oil are found to be an long life. As a result, the vegetable oil has a long-term stability.

A Study of Chemical and Mechanical Properties of the Mineral and Synthetic Oil Added with Two Different Zn-DTPs (Zn-DTP를 첨가한 공유와 합성유의 화학적 기계적 성질에 관한 연구)

  • 박미선;조원오;한두희;강석춘;김종호
    • Tribology and Lubricants
    • /
    • v.10 no.1
    • /
    • pp.78-88
    • /
    • 1994
  • For the study of chemical and mechanical properties of the synthetic and mineral oil added with two different Zn-DTPs, base and formulated oils were analyzed and compared. Kinematic viscosity and total acid number (TAN) were tested at high temperature for formulated oils. Also the oils added with different alkyl groups of Zn-DTP were tested for thermal stability and TAN changes. The 4-ball machine was used to test for the mechanical properties, such as the coefficient of friction and wear. The worn areas after sliding test were analyzed with microscope and EDX, too. From the study, mineral and synthetic oil have different effects according to the various added ratio of the primary and secondary alkyl groups of Zn-DTP. Also the temperature of test oil affected the anti-wear and friction property of the formulated oils. For synthetic oil, the primery alkyl group of Zn-DTP made better friction properties than that of secondary, while, for mineral oil, secondary alkyt group was better only at low temperature for mineral oil.

Control of Potato Virus Y (PVY-VN) with Mineral Oil Treatment in Tobacco Burley 21 Fields (담배(Burley 21) 포장에서 mineral oil 처리에 의한 감자바이러스Y(PVY-VN) 방제)

  • 채순용;김상석;김영호;박은경
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.2
    • /
    • pp.115-122
    • /
    • 2001
  • The effect of mineral oil treatment in Burley 21 tobacco field on the control of potato virus Y(PVY-VN) mostly transmitted by green peach apid(Myzus persicae Sulzer) in nature was studied and the virus infection in some plants including potato, pepper, bramble, radish, etc near the tobacco fields as a virus infection source was tested by capillary tube precipitatioin test with PVY-antibody and bioassay in Xanthi-nc tobacco. The main source of PVY-VN infection in tobacco field in korea was potato(ca. 40% of test plants infected). Pepper and bramble were also infected by PVY-VN. The control level of PVY-VN infection by treatment of 0.75% liquid mineral oil with 3 % nonionic emulsifier to the plants was 84.8 % in case of the artificial transfection with a infected apterous aphid in laboratory. However, the reduction of PVY-VN disease severity in tobacco fields treated with mineral oil at late June was only 35.5%. These results suggest that mineral oil treatment is not so effective for the protection of aphid-born virus(PVY - VN) infection in tobacco fields.

  • PDF

A Case of Diagnosis and Treatment of Scabies Using Mineral Oil Examination (광유(Mineral oil)법을 통한 옴(Scabies) 진단 및 치료 증례)

  • Jeong, Mi-rae;Kwon, Kang;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.34 no.4
    • /
    • pp.164-170
    • /
    • 2021
  • Objectives : The purpose of this study is to report the diagnosis and treatment of scabies using mineral oil examination and sulfur. Methods : Mineral oil is dropped on the skin lesion area and the burrow, and then scrape 6-7 times with blade 11. Collect the contained mineral oil, place it on a slide, and observe it under an optical microscope. After the scabies were confirmed, sulfur was applied to the whole body once a day. Results : When examined 2 weeks after treatment, scabies and feces were not observed and symptoms were relieved. Conclusions : Mineral oil examination is recommended to confirm scabies, and sulfur can be used to treat scabies.

Study of Dielectric Properties of a Potential RBD Palm Oil and RBD Soybean Oil Mixture as Insulating Liquid in Transformer

  • Azmi, Kiasatina;Ahmad, Azmier;Kamarol, Mohamad
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2105-2119
    • /
    • 2015
  • This paper reported the experimental result of dielectric properties of Refined, Bleached and Deodorized Palm Oil (RBDPO) combined with 0-50% of Refined, Bleached and Deodorized Soybean Oil (RBDSO). The dielectric strength and relative permittivity of RBDPO/RBDSO was higher compared to mineral oil at all ranges of ratios and temperatures which indicated a positive sign for its possible use as insulating liquid in a transformer. All ratios of the RBDPO/RBDSO mixture also demonstrated lower dissipation factor compared to mineral oil at 40℃, 70℃ and 90℃. Apart from that, the kinematic viscosity for the oil mixtures shown exceeded the IEC 60296 as well as the mineral oil results. 70%RBDPO/30%RBDSO mixture ratio was chosen as the best mixing percentage after comparison was made with the mineral oil and IEC 60296 standard where the mixture accumulated the most satisfactory of dielectric properties hence making it as the potential candidate for palm and soybean-based transformer oil.

The Effects of the Mineral Oil on Skin under Casts for Relief of Skin Dryness and Pruritus (석고붕대 속 피부에의 미네랄오일 도포가 피부건조 및 소양감 완화에 미치는 효과)

  • Lee Byung-Sook;Baek Kyung-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.2
    • /
    • pp.187-197
    • /
    • 2003
  • Purpose: This experimental study was to verify the effects of the mineral oil on skin under casts for relief of skin dryness and pruritus. Method: Participants in the study were inpatients at C university hospital in D city who had long leg casts. The mineral oil was applied to the skin under the casts in the experimental group of 18 patients and was not applied to the control group, also 18 patients. During the experimentation, the participants in the experimental group were informed about how to apply the mineral oil and 1 week later were responsible for applying the oil themselves. The oil was applied three times a day. Data collection was done from July 28, 2002 to September 28, 2002. The analyses were carried using frequencies, percentages, $x^2$-test, t-test, and repeated measures ANOVA with the SPSS WIN 10.0 program. Results: Hypothesis 1, 'The experimental group using the mineral oil application showed remarkably less dryness in the skin compared to the control group' was accepted (F=16.39, p=0.000). Hypothesis 2, 'The experimental group using the mineral, oil application showed remarkably less pruritus compared to the control group' was accepted (F=34.01, p=0.000). Conclusion: These results demonstrate that mineral oil application to skin under casts was effective in treating skin dryness and pruritus. Accordingly, it is concluded that mineral oil application to skin under casts can be an effective nurse intervention to treat skin dryness and pruritus.

  • PDF