• Title/Summary/Keyword: Mock-up

Search Result 802, Processing Time 0.036 seconds

Study on Substitution Effect caused by Application of BIM Simulation System to Mock-up Site (시공단계 현장 Mock-up의 BIM 기반 시뮬레이션 기법 적용에 의한 기대효과 분석 연구)

  • Jang, Se-Jun;Yun, Seok-Heon;Paek, Joon-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.147-151
    • /
    • 2008
  • Construction project is completed through several stages and problems of each stage affect directly not only now but also next. Defect of 2D drawings influence in construction phase, and it make many loss on project. Nowadays we practically use real Mock-up test in construction sites to solve the problems. But it also has many problems which are waste much money and time. Therefore, this study tries to analyze effect that is occurred by appling BIM Mock-up simulation instead of real Mock-up execution. These analysis is conducted by comparing two construction building site. These have same shape but one is made for BIM Mock-up, and another is real Mock-up. Comparison points of view are cost, time and operator's satisfaction. It is expect that BIM Mock-up is more effective at low cost and on shorter time. But our analysis show that each are conducted different part of function. So new Mock-up type is required. Hybrid Mock-up is combine real mock-up with BIM simulation and it can minimize risk of project.

  • PDF

하나로 조사시험용 캡슐 Mock-up의 건전성 평가

  • 주기남;박종만;강영환
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.663-668
    • /
    • 1996
  • 하나로를 이용한 재료조사시험용 계장캡슐 개발에 앞서 캡슐 mock-up (96M-01K)을 제작하였으며, 이 캡슐 mock-up의 실제 하나로 조사시험공 장입시를 가정하여 강도 및 열적 건전성 평가를 수행하였다. 평가 결과 하나로 정상출력시 (30MW) 캡슐 mock-up 내 조사시료의 온도는 진공 및 heating system을 사용하여 279~473$^{\circ}C$ 범위로 조절될 수 있었으며, 목표 조사기간 동안 캡슐 mock-up은 강도적으로 허용기준을 충분히 만족함으로써 안전한 것으로 판명되었다. 향후 본 캡슐 mock-up을 이용한 노외 simulation 실험 등을 통하여 기존 캡슐 mock-up의 건전성을 확인한 후 이를 기준으로 하여 표준형 하나로 캡슐을 설계 .제작하고자 한다.

  • PDF

A study on the improvement of The standard specifications for Mock-up Test in the Curtain-wall construction (Curtain-wall공사에 있어서 Mock-up Test 건축공사표준시방서의 개선 방안에 관한 연구)

  • Lee Jin-Man;Kang Jae-Wang;Son Yong-Geun;Kim Chang-Duk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.491-494
    • /
    • 2003
  • Curtain wall (for the outside wall) must be designed and constructed to resist weather condition of nature like rain. wind and surrounding environment. So, Now days, Mock-up test of curtain wall's total capability is generally used for skycraft building. But, Mock-up test specification in korea is so weak that there are lots of disputation. Also, lacking of clearness in specification causes many trouble in adaptation. Therefore, I would like to consider the problem of Mock-up test specification by inspecting and comparing with other country's works. and I will mention the way of approvement in our specification.

  • PDF

An Experimental Study on the Level Control of the Steam Generator in Nuclear Power Plant (원자력발전소 증기발생기 수위제어에 대한 실험적 연구)

  • 문제선;양명승;김기현;유재석;박영무
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.170-175
    • /
    • 1997
  • An experimental study was carried out with the Mock-up made for the improved water level control of the steam generator in nuclear power plant and for the confirmation of swell/shrink status of the water level by opening and closing the steam dump valve. We can confirmed the possibility of using the Mock-up by introducing the PI controller and the FUZZY controller. Accordingly, we can confirmed that the practical usability of advanced controllers, which will be developed for the improved water level control of the steam generator in nuclear power plant by using the Mock-up.

  • PDF

Study on Analysis Method for Ship's Ferromagnetic Signature using Magnetic Mock-up Model (축소 모델을 이용한 함정 자기장 신호 해석 기법 연구)

  • Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.38-51
    • /
    • 2007
  • This paper describes research results for the measurement and analysis method of magnetic signatures generated from the ship's magnetic mock-up model. In this paper, we present the theoretical and experimental techniques for the separation of the permanent and the induced magnetic field from the measured magnetic signature of the mock-up model. Also, we describe the prediction method of the induced magnetic field generated from mock-up model using the Magnet s/w, one of the FEM analysis tools for the electro-magnetic field and the magnetic dipole modelling method based on the least square techniques. The proposed modelling and analysis methods can be used for the prediction and the analysis of the static magnetic field generated from the real naval ship as well as the mock-up model.

Mock Up Test of High Durable Concrete for Mega Foundation (Mega Foundation용 고내구성 콘크리트의 성능 평가를 위한 Mock Up Test)

  • Woo, Seung-Min;Kim, Kil-Soo;Jun, Sung-Yong;Lee, Joo-Ho;Cho, Sung-Hyun;Kim, Jong-Baek
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.185-186
    • /
    • 2010
  • For Mega foundation, concrete must have high strength and high flowability. Especially in marine environment, concrete durability becomes a significant property. In this study, high durable concrete, under marine environment, was developed. And to estimate its performance, the world's biggest Mock Up test, $4m{\times}4m{\times}4m$ size, was performed.

  • PDF

A Comparison Evaluation on the Indoor Temperature and Humidity Control Effect of Hwang-To Brick and Traditional Window as Exterior envelops in Mock-up Room (Mock-up 실험을 통한 황토벽과 전통창호의 실내 온습도 조절효과에 대한 비교평가)

  • Song, Min-Jeong;Shin, Hoon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • This study aims to know temperature and humidity handling ability of Hwang-To brick and traditional paper window's in mock-up room test. To achieve these goals, mock-up room test was carried out. The results are as follows. 1) There are no significant differences among specimen in temperature handling capacity. 2) Traditional paper windows are very sensitive when compared with glass window in humidity control. 3) Traditional paper windows have a big handling capacity in humidity control when vapors letting out in mock-up room. 4) Hwang-To brick case is more stable than other cases in relative humidity variances because it has more potential to contain humidity.

Half-Mask Interface Prototype Design using Korean Face Anthropometric Data (한국인 안면부 인체 데이터를 이용한 마스크 계면 프로토타입 설계)

  • Song, Young-Woong;Yang, Won-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.87-92
    • /
    • 2010
  • The mask-face interface design should consider the face shape to improve the half mask respirator's fit ratio. This study tried to design the mask-face interface using recent Korean face data. By using the data of 1536 men's 3D face scanning (Size Korea data), head clay mock-up was made and mask-face interface line was extracted from this head mock-up. Using this interface line, the half-mask prototype was made. According to the quantitative fitting test, the proposed mask was found to be well fitted (average fit-ratio > 100). The proposed method had two advantages. 1) The method could use massive head-related anthropometric data like Size Korea data. 2) The qualitative fit test (observation) could be conducted very quickly by fitting the prototype to the head mock-up. However, this method also had several limitations. 1) The head clay mock-up could be different according to the mock-up maker. 2) The average values of the head-related anthropometric data were used to make the head mock-up. Small and large size head mock-ups should be made and tested.

The Loading Mock-up test for Construction Management of Cable net Facade (케이블넷 파사드의 시공관리를 위한 하중재하 Mock-up실험)

  • Moon, Sang-Deok;Ock, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.28-29
    • /
    • 2014
  • Cable net system openness and flexibility is good high and the large deflection caused no damage to the structure itself. However, cable installation, install complex systems and technologies are needed. In this study, for the basic materials of cable net construction management, cable net expert's advice and mock-up test results are summarized.

  • PDF

Mock up test and Field Application of Black Concrete Applying Superplasticizer containing Carbon Amino Silica Black (카본아미노실리카 블랙 고성능감수제(CASB-SP)를 사용한 블랙콘크리트의 Mock-up Test 및 현장적용)

  • Hong, Seok-Min;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.627-633
    • /
    • 2013
  • This paper presents the result of a mock-up test and field application of concrete that is black in color thanks to the application of superplasticizer containing carbon amino silica black (CASB-SP). Mock-up specimen with a size of $3000{\times}1500{\times}40$ mm was fabricated with black concrete applying 0.5% of CSAB-SP with 27 MPa. After dividing the zone in wall mock-up specimen, three different water repelling agents were applied to verify its effect of efflorescence prevention. It was found that the use of CASB-SP with 0.5% made the black concrete develop a highly clear black color, and the epoxy type water repelling agent had better performance in efflorescence prevention. Based on mock-up test, field application was conducted with bridge member. It was also found that the application of CASB-SP showed favorable results in black color development.