• Title/Summary/Keyword: Mode II

Search Result 744, Processing Time 0.032 seconds

Modified DEBA for determining size dependent shear fracture energy of laminates

  • Goodarzi, M. Saeed;Hosseini-Toudeshky, Hossein
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.111-121
    • /
    • 2018
  • It has been argued that fracture energy of composite laminates depends on their thickness and number of layers. In this paper a modified direct energy balance approach (DEBA) has been developed to evaluate the mode-II shear fracture energy for E-glass/Epoxy laminates from finite element model at an arbitrary thickness. This approach considers friction and damage/plasticity deformations using cohesive zone modeling (CZM) and nonlinear finite element modeling. The presence of compressive stress and resulting friction was argued to be a possible cause for the thickness dependency of fracture energy. In the finite element modeling, CZM formulation has been developed with bilinear cohesive constitutive law combined with friction consideration. Also ply element have been developed with shear plastic damage model. Modified direct energy balance approach has been proposed for estimation of mode-II shear fracture energy. Experiments were performed on laminates of glass epoxy specimens for characterization of material parameters and determination of mode-II fracture energies for different thicknesses. Effect of laminate thickness on fracture energy of transverse crack tension (TCT) and end notched flexure (ENF) specimens has been numerically studied and comparison with experimental results has been made. It is shown that the developed numerical approach is capable of estimating increase in fracture energy due to size effect.

혼합모드 I+II 피로 하한계 영역에서의 모드II 영향에 관한 고찰

  • 홍석표;송삼홍;이정무
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.113-113
    • /
    • 2004
  • 실제 사용중인 기계나 기계구조물은 다양한 환경 및 복잡한 설계조건으로 인하여 변동하중과 다축에서 작용하는 혼합모드 하중 상태에 놓이는 경우가 대부분이다. 하지만, 순수 모드 I 하중상태 하에서의 연구는 활발히 이루어졌으나, 실제 구조물에서 대부분 발생하는 혼합모드 하중상태 하에서의 연구는 아직 부족한 실정이다. 또한 기계구조물내의 많은 성분요소에 존재하는 작용 하중 방향에 수직적이지 않게 되며, 초기균열의 균열선상에서 성장하지 않는다.(중략)

  • PDF

Synthesis, crystal structure, and analytical characterizations of amphiphilic palladium(II) compound containing bis(benzylthio)methylenepropanedioate

  • Tae Hwan Noh
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.198-203
    • /
    • 2023
  • The reaction of cis-protected (Me4en)Pd(II) species with potentially multidentate bis(benzylthio)methylenepropanedioate (L) was carried out to obtain a monometallic compound, [(Me4en)Pd(L)], in O,O'-coordination mode. The bis(benzylthio)methylene group was bent strikingly from the palladium square plane at the dihedral angle of 70.40°. The physicochemical properties of the present palladium(II) compound were fully characterized by means of infrared and nuclear magnetic resonance spectroscopy, thermogravimetric analysis, and single-crystal X-ray diffraction measurement.

The Effect of Behavior Fatigue Crack Propagation on 2-Axle Load Frequency (2축 하중주파수가 피로균열진전거동에 미치는 영향)

  • Kim, Sang-Hee;Li, Jing-Hua;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.78-84
    • /
    • 2015
  • The stress state acting on mechanical parts and structures is generally mixed stress. This complex stress state, which is subject to changes in the environment, will produce many. Cars running on roads with different road conditions will subject the automotive parts to combined stress state. In the x direction and the y direction, a different amplitude and frequency of the fatigue load can be present. However, the load amplitude for Mode I and Mode II in a 2-axis fatigue test is limited to a constant ratio; the load frequency is always the same for any mode. In this paper, it is verified how the variation of the load frequency for mode II affects the behavior of fatigue crack propagation under mixed mode.

Mixed mode fracture assessment of U-notched graphite Brazilian disk specimens by means of the local energy

  • Torabi, A.R.;Berto, F.
    • Structural Engineering and Mechanics
    • /
    • v.50 no.6
    • /
    • pp.723-740
    • /
    • 2014
  • A fracture criterion based on the strain energy density (SED) over a control volume, which embraces the notch edge, is employed in the present paper to assess the fracture loads of some U-notched Brazilian disk (UNBD) specimens. The specimens are made of commercial graphite and have been tested under pure mode I, pure mode II and mixed mode I/II loading. The results show that the SED criterion allows to successfully assess the fracture loads of graphite specimens for different notch tip radii and various mode mixity conditions with discrepancies that fall inside the scatter band of ${\pm}20%$.

Mixed-mode fatigue crack growth behaviors in 5083-H115 aluminum alloy (5083-H115 알루미늄 합금의 혼합 모우드 피로 균열성장 특성)

  • 옹장우;진근찬;이성근;김종배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.461-471
    • /
    • 1989
  • For the mixed-mode crack problems the direction of crack growth, the crack path and the rational representation of fatigue crack growth rates should be studied to predict fatigue life and safety of structures. In this study, a round specimen which produce nearly identical effects in all loading directions is proposed to make an easy measurement of initial direction of crack growth. The mode I and mode II stress intensity factors of the specimen were calculated using finite element method, in which the square root singular stresses at the crack tip are modeled by means of four rectangular quarter-point eight-noded elements surrounding the crack tip. Experimental results for high strength aluminum alloy showed that the direction of mixed-mode crack growth agree well with maximum principal stress criterion as well as minimum strain energy density criterion, but not with maximum shear stress criterion. From data of fatigue crack growth rates using crack geometry projected on the line perpendicular to the loading direction it is easily established that mixed-mode fatigue crack growth in 5083-H115 aluminum alloy goes predominantly with mode I crack growth behaviors.

Crack Face Friction Effects on Mode II Stress Intensities for a Surface-Cracked Coating In Two-Dimensional Rolling $Contact^{\copyright}$ (구름접촉 하중시 코팅 표면에 발생한 균열면의 마찰을 고려한 모드II 전파거동에 관한 연구)

  • Moon Byung-Young;Kim Byeong Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.159-167
    • /
    • 2005
  • This work focuses on the effects of crack free friction on Mode II stress intensity factors, $K_{II}$, for a vertical surface crack in a two-dimensional finite element model of TiN/steel subject to rolling contact. Results indicate that maximum $K_{II}$ values, which occur when the load is adjacent to the crack, may be significantly reduced in the presence of crack face friction. The reduction is more significant for thick coatings than for thin. Crack extension and increased layer thickness result in increased $K_{II}$ values. The effect of crack face friction on compressive $K_I$ values appears negligible. Comparative results are presented for $MoS_2/steel$ and diamond-like carbon(DLC)/Ti systems.

Prediction of Progressive Interlaminar Fracture in Curved Composite Laminates Under Mode I Loading (모드 I 하중하에서 곡률이 있는 복합재 적층판의 점진적 층간파손 예측)

  • Kang, Seunggu;Shin, Kwangbok;Lee, HyunSoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.930-932
    • /
    • 2017
  • In this paper, prediction of progressive interlaminar fracture in curved composite laminates under mode I loading was described. The prediction of progressive interlaminar fracture in curved composite laminates was conducted using cohesive zone model(CZM) in ABAQUS V6.13. Interlaminar fracture toughness used as input parameters in CZM was obtained through mode I, mode II and mixed mode I/II tests. The behaviors of progressive interlaminar fracture for curved composite laminates showed a good agreement between experimental and numerical results.

  • PDF

A Pilot-Scale Microfiltration/Ultrafiltration system for Drinking Water Treatment (상수처리를 위한 파일롯 규모의 정밀여과/한외여과 시스템)

  • Kim, Hanseung;Oh, Jeongik;Kim, Chunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.770-777
    • /
    • 2004
  • Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.

Effect of the thickness on the mixed mode crack front fields

  • Khan, Shafique M.A.
    • Structural Engineering and Mechanics
    • /
    • v.42 no.5
    • /
    • pp.701-713
    • /
    • 2012
  • Results pertaining to 3D investigations on the effect of the thickness on the stress fields at the crack front are presented. A 3D finite element analysis is performed using a modified single edge-notched tension specimen configuration, with an inclined crack to include mixed mode I-II. A technique to mesh the crack front (3D) with singular finite elements in ANSYS without using third party software is introduced and used in this study. The effect of the specimen thickness is explicitly investigated for six thicknesses ranging from 1 to 32 mm. In addition, three crack inclination angles, including pure Mode-I, are used to study the effect of mixed-mode I-II fracture. An attempt is made to correlate the extent of a particular stress state along the crack front to thickness. In addition, ${\sigma}_{zz}/{\nu}({\sigma}_{xx}+{\sigma}_{yy})$ contours at the crack front are presented as a useful means to analyze the stress state.