• Title/Summary/Keyword: Monitoring %26 control system

Search Result 64, Processing Time 0.022 seconds

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

Remote Calibration Control and Monitoring System for Conveyor Scale using LabVIEW (LabVIEW를 이용한 Conveyor Scale의 원격 교정제어 및 모니터링 시스템)

  • Bang, Nam-Soo;Jang, Woo-Jin;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.72-80
    • /
    • 2012
  • In general, electronic conveyor scales are installed in a relatively distributed manner on the crushed rock and sand production site. It is one of the time-consuming and difficult engineering works to monitor and control the plant operation status such as the management of measuring data, malfunction of belt conveyor, and fault of electronic conveyor scale. Therefore, to alleviate the inefficient problems and to monitor the operating plant in the online and remote control room, a remote calibration and real-time monitoring system, which is practically applied to the electronic conveyor scale system and verified by onsite experiment, is developed based on the LabVIEW.

Simultaneous out-of-plane and in-plane vibration mitigations of offshore monopile wind turbines by tuned mass dampers

  • Zuo, Haoran;Bi, Kaiming;Hao, Hong
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.435-449
    • /
    • 2020
  • To effectively extract the vast wind resource, offshore wind turbines are designed with large rotor and slender tower, which makes them vulnerable to external vibration sources such as wind and wave loads. Substantial research efforts have been devoted to mitigate the unwanted vibrations of offshore wind turbines to ensure their serviceability and safety in the normal working condition. However, most previous studies investigated the vibration control of wind turbines in one direction only, i.e., either the out-of-plane or in-plane direction. In reality, wind turbines inevitably vibrate in both directions when they are subjected to the external excitations. The studies on both the in-plane and out-of-plane vibration control of wind turbines are, however, scarce. In the present study, the NREL 5 MW wind turbine is taken as an example, a detailed three-dimensional (3D) Finite Element (FE) model of the wind turbine is developed in ABAQUS. To simultaneously control the in-plane and out-of-plane vibrations induced by the combined wind and wave loads, another carefully designed (i.e., tuned) spring and dashpot are added to the perpendicular direction of each Tuned Mass Damper (TMD) system that is used to control the vibrations of the tower and blades in one particular direction. With this simple modification, a bi-directional TMD system is formed and the vibrations in both the out-of-plane and in-plane directions are simultaneously suppressed. To examine the control effectiveness, the responses of the wind turbine without control, with separate TMD system and the proposed bi-directional TMD system are calculated and compared. Numerical results show that the bi-directional TMD system can simultaneously control the out-of-plane and in-plane vibrations of the wind turbine without changing too much of the conventional design of the control system. The bi-directional control system therefore could be a cost-effective solution to mitigate the bi-directional vibrations of offshore wind turbines.

Development of Monitoring System for Wind Turbine (풍력발전기 원격모니터링 시스템 구축 및 개발)

  • Cha, Jang-Hyun;Lee, Jeong-Wan;Yoo, Neung-Soo;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.63-68
    • /
    • 2006
  • In this paper, remote monitoring system for wind turbine is developed. The developed system consists of data acquisition for wind sensor, and monitoring for site environment. In order to accomplish effective monitoring, the system uses Datasocket, SMB, FTP, Web Server, and G Web Server. Two computer system - one is data acquisition computer using Windows-XP and the other is monitoring computer using UNIX - constraint the distribute system with individual tasks. By using this system, one can perform various monitoring and control tasks in Wind-Turbine application, efficiently.

  • PDF

Design of Multi-protocol IED for Networked Control System of Multi-Induction Motor in Industrial Fields

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.60-71
    • /
    • 2012
  • This paper proposes a new design and implementation of multi-protocol IED for networked control system of multi-induction motor in industrial fields. The experimental multi-induction motor based multi-protocol IED of Modbus/LonTalks/TCP/IP module is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting Modbus protocol to LonTalks protocol, integrating preconfigured software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, especially, the seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide available technical data for remote distributed motor control system of industrial field or building microgrid with LonWorks BAS.

Development of COMS DATS C&M S/W (통신해양기상위성 송수신자료전처리시스템의 감시 및 제어 소프트웨어 개발)

  • Kim, Su-Jin;Park, Durk-Jong;Koo, In-Hoi;Ahn, Sang-Il
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.127-140
    • /
    • 2009
  • COMS DATS C&M software is an integrated management system providing control and monitoring functionalities for COMS IDACS (Image Data Acquisition and Control System). DATS C&M S/W consists of a system management module, a control and monitoring module, a data management module, and a trend analysis module. COMS SOC is supposed to operate IDACS as a backup of MSC. Especially, for the backup operation, the control and monitoring module of DATS C&M S/W is designed to support the synchronization of the two IDACS systems. This paper describes design, implementation, and result of development of DATS C&M S/W.

Development of Offshore Construction ROV System applying Pneumatic Gripper (공압 gripper를 적용한 해양 건설 ROV 시스템 개발)

  • Park, Jihyun;Hwang, Yoseop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1697-1705
    • /
    • 2022
  • The safety of marine construction workers and marine pollution problems are occurring due to large-scale offshore construction. In particular, underwater construction work in the sea has a higher risk than other work, so it is necessary to apply an unmanned alternative system that considers the safety of the workers. In this paper, the ROV system for offshore construction has been developed for underwater unmanned work. A monitoring system was developed for position control through the control of underwater propellants, pneumatic gripper, and monitoring of underwater work. As a result of the performance evaluation, the underwater movement speed of the ROV was evaluated to be 0.89 m/s, and it was confirmed that the maximum load of the pneumatic gripper was 80 kg. In addition, the network bandwidth required for underwater ROV control and underwater video streaming was evaluated to be more than 300Mbps, wired communication at 92.7 ~ 95.0Mbit/s at 205m, and wireless communication at 78.3 ~ 84.8Mbit/s.

INFORMATION SYSTEM ON INTEGRATED RADIATION SAFETY (ISIRS) AND ORPHAN SOURCES CONTROL IN KOREA

  • Lee, Dewhey
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.255-263
    • /
    • 2001
  • An Orphan Sources Control program controlled by a web based information system in Korea has been developed to satisfy the national demand on a total management of and integrated radiation safety. There are, currently, three approaches going on to control and manage the orphan sources in Korea. First, Korean regulatory authority has been conducting scrutinizing investigation on and thoroughly monitoring the possession of unlicensed radioactive sources from the late 1990s. Second, the regulatory authority will fully operate an information system on radiation safety to effectively trace and monitor all radioactive sources in the country by the mid 2001. Finally, the regulatory authority strongly advises steel mill companies to closely scrutinize and inspect the scrap metals when they attempt to reutilize metals to prevent from being contaminated by uncontrolled sources through the scrap monitoring systems.

  • PDF

A change point estimator in monitoring the parameters of a multivariate IMA(1, 1) model

  • Sohn, Sun-Yoel;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.2
    • /
    • pp.525-533
    • /
    • 2015
  • Modern production process is a very complex structure combined observations which are correlated with several factors. When the error signal occurs in the process, it is very difficult to know the root causes of an out-of-control signal because of insufficient information. However, if we know the time of the change, the system can be controlled more easily. To know it, we derive a maximum likelihood estimator (MLE) of the change point in a process when observations are from a multivariate IMA(1,1) process by monitoring residual vectors of the model. In this paper, numerical results show that the MLE of change point is effective in detecting changes in a process.

Study on the MQTT protocol design for the application of the real-time HVAC System

  • Jung, Hun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, the existing domestic HVAC systems, devices TCP / IP does not support the most, thereby, not performed remote management, it is necessary to regularly field service, inefficiency and cost bring a burden. This is through a comparison of the IoT-based primary, real-time protocol of what has become a hot topic recently, to be able to control and real-time monitoring through the CCU device in the HVAC system. Compare for this Internet of Things device for real-time monitoring and control of the XMPP, CoAP, MQTT main real-time protocol is used on. Finally, flexibility, light weight, based on MQTT a two-way messaging protocols with reliable message delivery, implements the protocol on the real-time HVAC system in the cloud platform.