• 제목/요약/키워드: Monolithic zirconia crown

검색결과 36건 처리시간 0.031초

지르코니아 단일구조 전부도재관의 파절강도 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS)

  • 정희찬
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

지르코니아 단일구조 전부도재관과 금속도재관의 파절강도 비교 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS AND METAL-CERAMIC CROWNS AFTER CYCLIC LOADING AND THERMOCYCLING)

  • 이상민;정희찬;전영찬
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.12-20
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm) Material and method: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling ($5-55^{\circ}C$, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups' fracture load before and after cyclic loading. Results: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. Conclusion: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.

Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type

  • Ha, Seung-Ryong
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.475-483
    • /
    • 2015
  • PURPOSE. The objective of this study was to evaluate the influence of various cement types on the stress distribution in monolithic zirconia crowns under maximum bite force using the finite element analysis. MATERIALS AND METHODS. The models of the prepared #46 crown (deep chamfer margin) were scanned and solid models composed of the monolithic zirconia crown, cement layer, and prepared tooth were produced using the computer-aided design technology and were subsequently translated into 3-dimensional finite element models. Four models were prepared according to different cement types (zinc phosphate, polycarboxylate, glass ionomer, and resin). A load of 700 N was applied vertically on the crowns (8 loading points). Maximum principal stress was determined. RESULTS. Zinc phosphate cement had a greater stress concentration in the cement layer, while polycarboxylate cement had a greater stress concentration on the distal surface of the monolithic zirconia crown and abutment tooth. Resin cement and glass ionomer cement showed similar patterns, but resin cement showed a lower stress distribution on the lingual and mesial surface of the cement layer. CONCLUSION. The test results indicate that the use of different luting agents that have various elastic moduli has an impact on the stress distribution of the monolithic zirconia crowns, cement layers, and abutment tooth. Resin cement is recommended for the luting agent of the monolithic zirconia crowns.

Fabrication of a CAD/CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis

  • Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Lee, Hyeonjong;Kim, Hyeong-Seob
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.329-332
    • /
    • 2016
  • Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP.

Monolithic Zirconia Crown을 이용한 심미적 접근 (Achieving Esthetics in Anterior Region using Monolithic Zirconia Restoration)

  • 김종화
    • 대한심미치과학회지
    • /
    • 제25권1호
    • /
    • pp.4-14
    • /
    • 2016
  • CAD/CAM이 치과계에 도입된지도 벌써 꽤 많은 시간이 흘렀음에도 불구하고 현재의 CAD/CAM은 여전히 비효율적이거나 또는 비심미적이다. '효율성' 과 '심미성'이란 두 단어는 지르코이나 보철물에 있어서는 양극에 위치하게 된다. 효율적이기 위해 도재소성없이 monolithic한 지르코니아 보철물을 만들다 보면 비심미적인 경우가 대부분이고, 거꾸로 심미적이기 위해 도재소성 과정을 거치다보면 여전히 사람의 손을 타게되는 비효율성을 피할 수 없기 때문이다. 이 글에서는 지르코니아 보철물의 현주소와 이와 관련된 몇가지 증례들을 보여드리고자 한다.

심미 수복 치료의 관점에서 바라본 Ko's Coloring을 이용한 Monolithic zirconia crown의 가능성 (Potential of monolithic zirconia crown using Ko's coloring)

  • 고경훈
    • 대한심미치과학회지
    • /
    • 제25권2호
    • /
    • pp.109-126
    • /
    • 2016
  • CAD/CAM의 발전으로 기존의 많은 보철물이 지르코니아로 대체되고 있다. 하지만 많은 치과기공사가 지르코니아 색조재현에 많은 어려움을 겪고 있다. 시행착오를 겪으며 이에대한 해결을 위해 많이 노력하였고 이에 이 논문에서는 Ko's coloring 기법에 대해 설명하고자 한다.

An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis

  • Yesilyurt, Nilgün Gulbahce;Tuncdemir, Ali Riza
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권4호
    • /
    • pp.216-225
    • /
    • 2021
  • PURPOSE. The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS. This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Three-dimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15° and 30° under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS. Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION. The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.

디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례 (Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration)

  • 최창훈;김선재
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.253-258
    • /
    • 2016
  • 최근 CAD-CAM과 지르코니아를 이용한 보철물의 제작이 증가하고 있으며 구강스캐너의 발달로 임상 및 기공과정이 단순화되고 있다. 균열치 혹은 치아의 일부가 파절된 경우, 구강스캐너를 사용하여 치아 삭제 전에 치아의 형태를 미리 스캔하고, 추후 수복물 제작 시 중첩을 통해 단일체 지르코니아 전장관을 제작하면 원래 환자의 자연치 형태와 교합을 재현할 수 있다. 본 증례에서는 균열 및 파절된 치아에서 구강 스캐너, CAD-CAM 및 단일체 지르코니아 전장관을 사용하여 삭제 전 치아의 형태와 교합을 재현한 수복물을 제작하였으며, 교합조정을 최소화할 수 있었다. 또한 임상적으로 기능적이고 심미적인 결과를 얻을 수 있었다.

착색용액과 Monolithic Zirconia를 이용한 심미적인 부위의 보철 치료 (Prosthetic treatment in esthetic area with monolithic zirconia using coloring liquid: a case report)

  • 이문호;김준성;박은철;김희중
    • 대한치과보철학회지
    • /
    • 제60권3호
    • /
    • pp.293-300
    • /
    • 2022
  • 최근 현대인들의 심미적인 치과 치료에 대한 관심이 증가하고 있고, 이와 관련된 다양한 재료와 수복물이 소개되고 있다. 특히 지르코니아는 우수한 강도와 내마모성을 지니며 생체친화성이 있다. 이러한 장점에도 불구하고, 지르코니아의 불투명한 백색으로 인해 전치부 수복치료시 심미적인 한계점이 있다. 최근 색조를 부여한 지르코니아 블록과 투명성이 높은 지르코니아 블록 및 다층 지르코니아 블록 등 다양한 지르코니아 블록이 개발되면서 단일 구조 지르코니아의 활용 범위가 확대되고 있다. 본 증례는 상악 전치부 보철물을 제작을 위해 단색의 Monolithic Zirconia를 이용하여 소결 전에 착색 용액을 도포하여 최종 수복물의 색조를 자연스럽게 재현하였다. 심미 보철 수복 치료시 착색용액을 이용한 지르코니아 사용을 통해 환자와 술자 모두 만족하는 심미적 보철물을 제작하였기에 이를 보고하는 바이다.

CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교 (Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report)

  • 용기훈;심준성
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.246-251
    • /
    • 2014
  • CAD/CAM을 이용하여 보철물을 제작할 경우 교합 접촉점의 위치, 면적, 형태를 원하는 대로 조절할 수 있으므로 보다 기능적인 교합의 부여가 가능하다. 또한 전통적인 Casting 기법을 이용한 주조금속 보철물이나, Porcelain의 축성을 통해 제작된 보철물에 비하여 제작과정 중의 오차가 감소하여 우수한 교합 정확도를 얻을 수 있을 것으로 기대되고 있다. 그리고 최근 소개되고 있는 CAD/CAM system에는 가상 교합기 기능이 추가되어 단일 수복물의 설계에서도 상악에 대한 하악의 운동을 재현함으로써 폐구 운동 뿐만 아니라 전/측방 운동시의 교합간섭을 고려할 수 있게 되었다. 그 동안 zirconia를 이용한 보철물의 변연 및 내면 적합도에 대한 연구는 많이 이루어졌으나 CAD/CAM을 이용해 설계된 zirconia crown의 교합 적합도에 대한 연구는 많이 이루어지지 않았다. 따라서 본 증례에서는 총 5명의 환자에서 CAD/CAM을 이용하여 제작된 7개의 지르코니아 크라운을 대상으로, 처음 설계된 zirconia crown의 교합 접촉점과 조정과정을 거쳐 구강 내 시적 후에 제작된 모델을 스캔하여 획득된 교합 접촉점을 비교하여 보철물의 정확도를 평가하고 교합조정의 양상을 파악해 보고자 하였다. 지르코니아 크라운에서 이루어진 교합조정은 대부분 기능교두 및 사면부위에서 이루어졌으며 15 - $60{\mu}m$의 분포를 보였다. CAD/CAM을 이용하여 제작된 지르코니아 크라운에서 어느정도의 교합조정은 불가피한 과정이며 이에 따른 물성저하를 보상하기 위한 추가적인 과정이 필요할 것이다.