• Title/Summary/Keyword: Multi-Level

Search Result 4,705, Processing Time 0.032 seconds

A study on Adaptive Multi-level Median Filter using Direction Information Scales (방향성 정보 척도를 이용한 적응적 다단 메디안 필터에 관한 연구)

  • 김수겸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.611-617
    • /
    • 2004
  • Pixel classification is one of basic image processing issues. The general characteristics of the pixels belonging to various classes are discussed and the radical principles of pixel classification are given. At the same time. a pixel classification scheme based on image direction measure is proposed. As a typical application instance of pixel classification, an adaptive multi-level median filter is presented. An image can be classified into two types of areas by using the direction information measure, that is. smooth area and edge area. Single direction multi-level median filter is used in smooth area. and multi-direction multi-level median filter is taken in the other type of area. What's more. an adaptive mechanism is proposed to adjust the type of the filters and the size of filter window. As a result. we get a better trade-off between preserving details and noise filtering.

M/B-MC/CDMA performance analysis for high speed data transmission in IS-95 evolution (IS-95 진화방안에서 고속 데이터 전송을 위한 M/B-MC/CDMA 전송방식의 성능분석)

  • 임명섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1494-1500
    • /
    • 1999
  • In order to provide high speed multimedia data rate service, Multi-Code CDMA has been proposed which converts high speed serial data stream into N parallel low speed data streams with orthogonal PN codes for spreading. However this signal has multi level and causes interferences to be increased at the neighboring cell boundary in the reverse link. Therefore in order to solve the above mentioned problem, M/B-MC/CDMA, in which multi level signal is converted to binary level signal using M/B conversion, is proposed and the performance is compared with MC-CDMA.

  • PDF

MLR-tree : Spatial Indexing Method for Window Query of Multi-Level Geographic Data (MLR 트리 : 다중 레벨 지리정보 데이터의 윈도우 질의를 위한 공간 인덱싱 기법)

  • 권준희;윤용익
    • Journal of KIISE:Databases
    • /
    • v.30 no.5
    • /
    • pp.521-531
    • /
    • 2003
  • Multi-level geographic data can be mainpulated by a window query such as a zoom operation. In order to handle multi-level geographic data efficiently, a spatial indexing method supporting a window query is needed. However, the conventional spatial indexing methods are not efficient to access multi-level geographic data quickly. To solve it, other a few spatial indexing methods for multi-level geographic data are known. However these methods do not support all types of multi-level geographic data. This paper presents a new efficient spatial indexing method, the MLR-tree for window query of multi-level geographic data. The MLR-tree offers both high search performance and no data redundancy. Experiments show them. Moreover, the MLR-tree supports all types of multi-level geographic data.

Study on multi-unit level 3 PSA to understand a characteristics of risk in a multi-unit context

  • Oh, Kyemin;Kim, Sung-yeop;Jeon, Hojun;Park, Jeong Seon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.975-983
    • /
    • 2020
  • Since the Fukushima Daiichi accident in 2011, concerns for the safety of multi-unit Nuclear Power Plant (NPP) sites have risen. This is because more than 70% of NPP sites are multi-unit sites that have two or more NPP units and a multi-unit accident occurred for the first time. After this accident, Probability Safety Assessment (PSA) has been considered in many countries as one of the tools to quantitatively assess the safety for multi-unit NPP sites. One of the biggest concerns for a multi-unit accident such as Fukushima is that the consequences (health and economic) will be significantly higher than in the case of a single-unit accident. However, many studies on multi-unit PSA have focused on Level 1 & 2 PSA, and there are many challenges in terms of public acceptance due to various speculations without an engineering background. In this study, two kinds of multi-unit Level 3 PSA for multi-unit site have been carried out. The first case was the estimation of multi-unit risk with conservative assumptions to investigate the margin between multi-unit risk and QHO, and the other was to identify the effect of time delays in releases between NPP units on the same site. Through these two kinds of assessments, we aimed at investigating the level of multi-unit risk and understanding the characteristics of risk in a multiunit context.

A Novel Multi-Level Inverter Configuration for High Voltage Conversion System

  • Suh, Bum-Seok;Lee, Yo-Han;Hyun, Dong-Seok
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.2
    • /
    • pp.109-118
    • /
    • 1996
  • This paper deals with a new multi-level high voltage source inverter with GTO Thyristors. Recently, a multi-level approach seems to be the best suited for implementing high voltage conversion systems because it leads to harmonic reduction and deals with safe high power conversion systems independent of the dynamic switching characteristics of each power semiconductor device. A conventional multi-level inverter has some problems; voltage unbalance between DC-link capacitors and larger blocking voltage across the inner switching devices. To solve these problems, the novel multi-level inverter structure is proposed.

  • PDF

Simulation based Comparative Loss Analysis and Output Characteristic for 25MW Class of High Power Multi-level Inverters (25MW급 대용량 멀티레벨 인버터의 시뮬레이션 기반 손실해석과 출력특성 비교 분석)

  • Kim, I-Gim;Park, Chan-Bae;Baek, Jei-Hoon;Kwak, Sang-Shin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.337-343
    • /
    • 2015
  • The multi-level inverters are highly efficient for high-power and medium-voltage AC driving applications, such as high-speed railway systems and renewable energy resources, because such inverters generate lower total harmonic distortion (THD) and electromagnetic interface (EMI). Lower switching stress occurs on switching devices compared with conventional two-level inverters. Depending on the multi-level inverter topology, the required components and number of switching devices are different, influencing the overall efficiency. Comparative studies of multi-level inverters based on loss analysis and output characteristic are necessary to apply multi-level inverters in high-power AC conversion systems. This paper proposes a theoretical loss analysis method based on piecewise linearization of characteristic curves of power semiconductor devices as well as loss analysis and output performance comparison of five-level neutral-point clamped, flying capacitor inverters, and high-level cascaded H-bridge multi-level inverters.

Timing Recovery Algorithm with Slop Compensated for Multi-level PAM Signals (Multi-level PAM신호에 적용 가능한 기울기 보상 심볼타이밍 알고리즘)

  • 전광호;임명섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11A
    • /
    • pp.1864-1871
    • /
    • 2001
  • In this paper, new symbol timing recovery algorithm is proposed, which is suitable for the digital communication system with Multi-level PAM signals. In the newly proposed symbol timing recovery algorithm, the timing error function is derived by compensating the several difference values between sampled symbol and neighboring symbol every symbol period with mid samples and decided symbol values. Conventional symbol timing recovery methods did not work well in Multi-level PAM signals, but the newly proposed method can be applied to Multi-level PAM signals as well as QPSK. For the performance analysis, the derived variance of the timing error function and the timing error characteristics of S-curve show that the proposed method has better performance than Gardner method and the modified Gardner method.

  • PDF

Multi-level Analysis of Prefinitely Strainely concrete materials (대변형률이 발생한 콘크리트 재료의 다수준 해석)

  • 최재혁;송하원;김장호;박상순;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.405-410
    • /
    • 2000
  • Multi-level (macro-level, meso-level, and micro-level) mechanism of prefinitely strained concrete materials os studied The multi-level analysis explains the additional quasibrittle concrete material ductility that comes from lateral confinement and their multi-level interaction mechanisms. The so-called "upgraded tube-squash test" is used to achieve 50% axial strain and over 70 degree of deviatoric strain of quasibrittle concrete materials under extremely high pressure without producing visible cracks. In the micro-level analysis, the variations of hydration rte, micropores, and hydrate phased are analyzed. In the meso-level analysis, mesocracks (the initial invisible cracks) at the interfaces between aggregates and cement paste matrices are studied. The high confining effect in the specimen on the meso-level cracks is also studied. In the macro-level analysis, the physical behavior of prefinitely strained concrete materials is studied. The co-relationships of the results from the three distinct levels of analyses based in various prestraining (0%, 15%, 35%, and 50%) are studied. For the extremely deformed or strained concrete problems, multi-level analysis will be used to explain the unclear and unstudied mechanism of concrete materials, The multi-level analysis can provide us with valuable insights that can explain the additional ductility and confining effect in concrete. concrete.

  • PDF

Multi-Level FeRAM Utilizing Stacked Ferroelectric Structure (강유전성 물질을 이용한 Multi-level FeRAM 구조 및 동작 분석)

  • Seok Heon Kong;June Hyeong Kim;Seul Ki Hong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.73-77
    • /
    • 2023
  • In this study, we developed a Multi-level FeRAM (Ferroelectrics random access memory) device utilizing different ferroelectric materials and analyzed its operation through C-V analysis using simulations. To achieve Multi-level operation, we proposed an MFM (Multi-Ferroelectric Material) structure by depositing two different ferroelectric materials with distinct properties horizontally on the same bottom electrode and subsequently adding a gate electrode on top. By analyzing C-V peaks based on the polarization phenomenon occurring under different voltage conditions for the two materials, we confirmed the feasibility of achieving Multi-level operation, where either one or both of the materials can be polarized. Furthermore, we validated the process for implementing the proposed structure using semiconductor fabrication through process simulations. These results signify the significance of the new structure as it allows storing multiple states in a single memory cell, thereby greatly enhancing memory integration.

Multi-unit Level 2 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Cho, Jaehyun;Han, Sang Hoon;Kim, Dong-San;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1234-1245
    • /
    • 2018
  • The risk of multi-unit nuclear power plants (NPPs) at a site has received considerable critical attention recently. However, current probabilistic safety assessment (PSA) procedures and computer code do not support multi-unit PSA because the traditional PSA structure is mostly used for the quantification of single-unit NPP risk. In this study, the main purpose is to develop a multi-unit Level 2 PSA method and apply it to full-power operating six-unit OPR1000. Multi-unit Level 2 PSA method consists of three steps: (1) development of single-unit Level 2 PSA; (2) extracting the mapping data from plant damage state to source term category; and (3) combining multi-unit Level 1 PSA results and mapping fractions. By applying developed multi-unit Level 2 PSA method into six-unit OPR1000, site containment failure probabilities in case of loss of ultimate heat sink, loss of off-site power, tsunami, and seismic event were quantified.