• Title/Summary/Keyword: Multi-channel Analyzer

Search Result 32, Processing Time 0.026 seconds

Multi - channel Spectrum Analyzer for High Capacity Optical Transport Networks

  • Youn, Ji-Wook;Kim, Hyung-Joo;Lee, Jong-Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.249-252
    • /
    • 2003
  • A simple multi-channel spectrum analyzer using an InGaAs array sensor and a diffraction grating is proposed and developed for high-capacity optical transport networks. With the developed multichannel spectrum analyzer, we could measure signal power, wavelength, and optical signal-to-noise ratio of each channel for multi-channel optical signals with 100 GHz and 50 GHz channel spacing, simultaneously. We could measure each channel power and wavelength with a deviation of less than 0.2 dB and 0.063 nm, respectively. We have obtained optical signal-to-noise ratio with a deviation of less than 1.0 dB compared with conventional optical spectrum analyzer in the wide input power range between -42 dBm and -27 dBm per channel.

Analysis of Voice Parameters on Different Phonatory Tasks using Multi-Channel Phonatory Function Analyzer in Healthy Adults (다채널 음성분석장치를 이용한 정상 성인에서의 발성 방식에 따른 음성변수 분석)

  • 성명훈;이상준;김광현;노종렬;권택균;이강진;박광석;최종민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Background and Objectives : The complex physiologic structure of the larynx can vibrate in three or more different ways that yield acuostically and perceptually distinct vocal quality. The purpose of this study is to examine the normal range of voice parameters in Multi-Channel Phonatory Function Analyzer and investigate the difference of voice parameters according to the phonatory patterns. Materials and Methods : Forty normal adult speakers (20 men and 20 women) with age ranging from third to forth decades pronounce low, comfortable, and high tone /a/ ; comfortable tone /${\ae}$/, /i/, /o/, and /u/ : fry, falsetto. Voice was analyzed by Newly developed multi-channel phonatory function analyzer. Results : The normal range of voice parameters in this system was similar to the existing data. Fry shows high jitter and falsetto low SQ. Fry and falsetto show low OQ in men but no difference in women. Jitter, OQ and SQ were different between men and women in modal register, whereas there was no gender difference in fry and falsetto. In frequency magnitude spectrum and EGG, modal register, fry and falsetto have distinguishing pattern. Conclusions : Modal register, fry and falsetto are distinguishable in voice parameters and show different vibratory patterns.

  • PDF

Jitter and Shimmer Measurements of Dysphonia among the Different Voice Analysis Programs (각종 음성분석기에 따른 음성장애 환자의 주기간 주파수 및 진폭변동률 분석)

  • Choi Seong Hee;Nam Do-Hyun;Lee Seung-Hoon;Jung Won-Hyuk;Kim Deok-Won;Choi Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.2
    • /
    • pp.140-145
    • /
    • 2005
  • Background and Objectives : Voice perturbation measures, such as jitter and shimmer has been importantly used for diagnosis and treatment efficacy of laryngeal dysfunction. This study was conducted to investigate validity of newly developed multi-channel voice analyzer program by comparing with MDVP, PRAAT, TF32. In addition, we compared the voice perturbation measures with different voice analyzer program by type of signals. Materials and Methods : Nineteen mild-severe dysphonic patients participated in our study. Fundamental frequency, jitter and shimmer values were obtained from different voice analyzer program using the same sustained/ah/phonation. Results : Fundamental frequency and shimmer were highly correlated whereas jitter was weakly correlated between newly developed multi-channel voice analyzer program and the others though different pitch computation algorithm except MDVP, In addition, Type 2 and 3 signals were weakly correlated than Type 1. Conclusion : In the clinical setting, clinician may have sufficient information of voice analyzer and control conditions properly for severity of pathologic voice before voice perturbation measure to obtain reliable results.

  • PDF

A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis (방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구)

  • Hwang, I.K.;Kwon, K.H.;Song, S.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.784-791
    • /
    • 1995
  • This paper describes the counting-loss problem for radiation measurement Multi-channel analyzers and spectrometers adopt various techniques for compensation for counting-losses in process-ing the radiation pulses from a detector. Researchers hate tried to seek the best solution for the problem. However, any absolute solution has not been reached and vendors of radiation instruments use their own algorithms individually. This survey explains the various compensation algorithms with electronic implementation approach. Shortcomings and merits of each algorithm are also reviewed and a direction is suggested of the recommendable development strategy for counting-loss compensation.

  • PDF

Development of a multi-channel clinical chemistry analyzer (반사광을 이용한 다채널 임상화학분석기개발)

  • 유동주;송은영
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 1995
  • In this paper we report the device of a multi-channel clinical instrument developed for determi¬nation of the levels of the urinary urobilinogen, glucose, ketone, bilirubin, protein, ascorbic acid, nitrite, pH, occult-blood, specific gravity, and leukocytes semiquantitatively. The test parameters are expressed on the dry test strips as a range of color intensities by chemical reactions. The instrument measures the value of each substance by reading the reflectance light emanated from the test strips. We also designed the reagent strip cassette and loader in order to intercept the outside interference. The loader can be operated semi-automatically. The light source is consisted on light emitting diodes at three specific wavelengths (560 nm, 610 nm, 650 nm). Precision of the system was evaluated by testing a series of commercial control urine samples. Furthermore, the performance of the instrument was compared with two other test methods on the urine samples from 100 persons. Our results showed a good repeatability between tests and a satisfactory agreement between the readings by our instrument and visual evaluation.

  • PDF

Time-Delay Estimation in the Multi-Path Channel based on Maximum Likelihood Criterion

  • Xie, Shengdong;Hu, Aiqun;Huang, Yi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.4
    • /
    • pp.1063-1075
    • /
    • 2012
  • To locate an object accurately in the wireless sensor networks, the distance measure based on time-delay plays an important role. In this paper, we propose a maximum likelihood (ML) time-delay estimation algorithm in multi-path wireless propagation channel. We get the joint probability density function after sampling the frequency domain response of the multi-path channel, which could be obtained by the vector network analyzer. Based on the ML criterion, the time-delay values of different paths are estimated. Considering the ML function is non-linear with respect to the multi-path time-delays, we first obtain the coarse values of different paths using the subspace fitting algorithm, then take them as an initial point, and finally get the ML time-delay estimation values with the pattern searching optimization method. The simulation results show that although the ML estimation variance could not reach the Cramer-Rao lower bounds (CRLB), its performance is superior to that of subspace fitting algorithm, and could be seen as a fine algorithm.

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy (근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구)

  • Yoon, Sung-Un;Ma, Sang-Dong;Kim, Myung-Yun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

Paticle size analyzer using laser diffraction (레이저 회절성을 이용한 입자크기 분포의 계측 및 해석)

  • 남부희;강성귀;유태우;방병렬;지규인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.81-85
    • /
    • 1992
  • We design a multi-element photo-detector to measure the size of particles using the diffracted light energy distribution. The scattered profile measured by the photodetector is sampled by a 32 channel analog-to-digital converter. A nonnegative least squares analysis translates the light energy distribution into the corresponding unique particle size distribution. The responses of the particle sizing system are studied theoretically and experimentally.

  • PDF