• 제목/요약/키워드: Multi-path distribution line model

검색결과 4건 처리시간 0.021초

대칭 및 비대칭 유동장에서 다회선 초음파 유량계의 유속분포 적분 방법 평가 (Performance Evaluation of the Velocity Profile Integration for the Multi-Path Ultrasonic Flowmeter in Symmetric & Asymmetric Flow Field)

  • 김주영;김경진;박성하
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.370-377
    • /
    • 2002
  • Generally, the system of calculation for the multi-path ultrasonic flow meters can be divided into two methods by how to get the mean velocity, namely, weighting and direct method. Weighting-method derive the mean velocity through modeling in theoretical velocity profile. Direct-method derive the mean velocity though actual flow distribution. The system of calculation varies with maker's transducer configuration and integration method. Each system has merits and demerits. This paper describes the system of integration that calculates line velocity over cross-section of the circular pipe. Flow rate mr discussed in this paper is a difference between theoretical flow rate and integrated flow rate according to values of Reynolds number in symmetric flow field or theoretical flow rate and integrated flow rate according to rotated model in asymmetric flow field.

  • PDF

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

비접촉식 유도성 결합기를 이용한 다중경로 전력선 채널 특성 (Channel characteristics of multi-path power line using a contactless inductive coupling unit)

  • 김현식;손경락
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권9호
    • /
    • pp.799-804
    • /
    • 2016
  • 광대역 전력선 통신은 전류의 흐름과 함께 효과적인 양방향 통신을 얻기 위하여 전력선 분배망을 통신 매체로 이용한다. 그러나 전력선은 통신에 최적화된 채널이 아니므로 인터넷, 음성 및 데이터 서비스에 대한 통신 시스템의 개발은 시뮬레이션에 의한 성능 분석에 적합한 측정 기반의 전송 모델을 필요로 한다. 본 논문에서는 복잡한 전달 함수를 기술하는 분석 모델을 다중 전력선 모델의 감쇠 및 경로 파라미터를 획득하는데 이용하였으며 이를 바탕으로 주파수 응답특성을 계산하였다. 계산된 결과는 다중경로에 의한 주파수 선택성 페이딩과 주파수에 대한 신호의 감쇄를 보여주었으며 이는 실험 결과와 잘 일치하였다. 이론모델에 적용한 배전선을 실험적으로 구성한 후 배전선에 전기적인 신호를 인가하는 방법으로 비접촉식 결합을 위한 페라이트 코어로 구성된 유도 결합 장치를 사용하였다. 신호 결합 손실은 커플러에 감긴 권선수에 의해 최소화 될 수 있다. 3회 권선 결합 효율은 일회 권선 결과보다 6dB 이상 개선됨을 보였다.

A Systolic Parallel Simulation System for Dynamic Traffic Assignment : SPSS-DTA

  • Park, Kwang-Ho;Kim, Won-Kyu
    • 지능정보연구
    • /
    • 제6권1호
    • /
    • pp.113-128
    • /
    • 2000
  • This paper presents a first year report of an ongoing multi-year project to develop a systolic parallel simulation system for dynamic traffic assignment. The fundamental approach to the simulation is systolic parallel processing based on autonomous agent modeling. Agents continuously act on their own initiatives and access to database to get the status of the simulation world. Various agents are defined in order to populate the simulation world. In particular existing modls and algorithm were incorporated in designing the behavior of relevant agents such as car-following model headway distribution Frank-Wolf algorithm and so on. Simulation is based on predetermined routes between centroids that are computed off-line by a conventional optimal path-finding algorithm. Iterating the cycles of optimization-then-simulation the proposed system will provide a realistic and valuable traffic assignment. Gangnum-Gu district in Seoul is selected for the target are for the modeling. It is expected that realtime traffic assignment services can be provided on the internet within 3 years.

  • PDF