• 제목/요약/키워드: NaCl electrolyte

검색결과 234건 처리시간 0.027초

구리/NaCl 전해질/아연 전기화학전지의 전류특성 (Current characteristics of Cu/NaCl electrolyte/Zn electrochemical cell)

  • 김용혁
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1626-1631
    • /
    • 2010
  • The characteristics of electric current for the voltaic cell are important for electric power applications. In this paper, an electrical equivalent model consist of three resisters and a capacitance for the Cu/NaCl solution/Zn electrochemical cell is proposed. The capacitance which exists in the Zn electrode/electrolytic interface increased according to Zn electrode area, but cannot affect almost in electric current. Complex impedance plot was used to analysis the interface effect for Zn/electrolyte. This result shows that the interface is similar with the electric transmission line. The short current measurements were conducted to investigate the effects of hydrogen peroxide, the watery sulfuric acid and NaCl aqueous solution. As the hydrogen peroxide increased, the electric current increased because the hydrogen gas being converted with the water. Also electric current increased significantly with increase of the hydrogen ion with the watery sulfuric acid and increased with increase of $Na^+$ ion and $Cl^-$ion in the NaCl electrolyte.

전극재료에 따른 NaCl 전해질의 전기전도특성 (Electric Conduction Properties of NaCl Electrolyte as a Function of Electrode Materials)

  • 김용혁
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2026-2031
    • /
    • 2010
  • The electrical characteristics of galvanic cell which is composed of the cathode electrode(graphite, carbon and copper) and the anode electrode(Zn and Mg) were investigated. For this research as electrolyte 2~12 wt% NaCl aqueous solution were used. At graphite cathode electrodes which use Zn and Mg with the anode electrode, the open circuit voltage was 1.3V most highly. The maximum output power increased as the electrolyte concentration increased, due to a increase in ion density. When Zn and Mg with the anode electrode, the maximum output power respectively was evaluated as 2.2mW and 5.5mW about the graphite cathode electrode in the NaCl 4wt%. The research results indicated that the output power of cell which is composed with graphite with the cathode and Mg with the anode was most excellent and the efficiency of the cell could be enhanced by increasing the electrolyte concentration.

금속-공기전지의 Anode전극 반응에 관한 연구 (Study on the Anode Electrode Reaction in the Metal-Air Cell)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권12호
    • /
    • pp.1002-1006
    • /
    • 2010
  • In this study, magnesium (Mg), zinc (Zn) and aluminium (Al) as anode electrode and the solution of NaCl dissolved with 2~20 wt% as electrolytes were used for the metal-air cell. The open circuit voltage, short circuit current and I-V characteristics upon different kinds of anode electrode and electrolyte concentration were investigated. The open circuit voltage, initially about 1.45 V, rises to 1.6 V during the first 10 minutes indicating the necessity of an induction time to activate the catalyst on the air cathode. The short circuit current increases with an increased concentration of NaCl, causes an increase in the conductivity of the electrolyte solution, but the open circuit voltage did not under undergo influence of electrolyte. From NaCl 20 wt% electrolyte, the maximum output power of the magnesium electrode materials was measured with 177mW. It is found that the power characteristics of metal-air cell could be improved by using magnesium electrode materials in the NaCl electrolyte.

QCA를 이용한 폴리피롤 박막의 점탄성 특성에 대한 전해질 영향 (The Effect of Electrolyte on the Viscoelastic Characteristics of PPy Thin Film Using QCA)

  • 송성훈;김종민;한대상;박진영;박지선;장상목
    • 공업화학
    • /
    • 제10권5호
    • /
    • pp.784-788
    • /
    • 1999
  • 본 연구에서는 $Na_2SO_4,\;Na_2CO_3,\;SDS$$NaClO_4$ 전해질용액에서 피롤단량체를 전기중합한 후, 중합시간과 전해질에 따른 피롤중합막의 점탄성 특성을 QCA를 이용하여 분석하였다. 그리고, 180초간 피롤을 중합하여 피막한 수정진동자를 0.1 M $NaClO_4$ 전해질용액에 넣어서 전위주사하여 각각의 전해질에 대한 폴리피롤박막의 산화환원특성을 분석하였다. 본 실험에서는 수정진동자의 한쪽 전극을 작용전극으로 사용하였으며, 각각의 실험에서 공진주파수, 공진저항, 전류 값을 측정하여 분석하였다. 본 연구 결과, $ClO_4{^{-}}$$DS^-,\;SO_4{^{-2}},\;CO_3{^{-2}}$의 순서로 피롤막이 탄성막에서 점차 점탄성막으로 변하여 가면서 중합됨을 알 수 있었다.

  • PDF

고체 고분자 전해질(SPE)을 이용한 전기분해 공정에서 Rhodamine B 분해 (Degradation of Rhodamine B in Water using Solid Polymer Electrolyte (SPE) in the Electrolysis Process)

  • 박영식
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.137-146
    • /
    • 2014
  • Objectives: Feasibility of electrochemical oxidation of the aqueous non-biodegradable wastewater such as cationic dye Rhodamine B (RhB) has been investigated in an electrochemical reactor with solid polymer electrolyte (SPE). Methods: Nafion 117 cationic exchange membrane as SPE has been used. Anode/Nafion/cathode sandwiches were constructed by sandwiching Nafion between two dimensionally stable anodes (JP202 electrode). Experiments were conducted to examine the effects of applied current (0.5~2.0 A), supporting electrolyte type (0.2 N NaCl, $Na_2SO_4$, and 1.0 g/L NaCl), initial RhB concentration (2.5~30.0 mg/L) on RhB and COD degradation and $UV_{254}$ absorbance. Results: Experimental results showed that an increase of applied current in electrolysis reaction with solid polymer electrolyte has resulted in the increase of RhB and $UV_{254}$ degradation. Performance for RhB degradation by electrolyte type was best with NaCl 0.2 N followed by SPE, and $Na_2SO_4$. However, the decrease of $UV_{254}$ absorbance of RhB was different from RhB degradation: SPE > NaCl 0.2 N > $Na_2SO_4$. RhB and $UV_{254}$ absorbance decreased linearly with time regardless of the initial concentration. The initial RhB and COD degradation in electrolysis reaction using SPE showed a pseudo-first order kinetics and rate constants were 0.0617 ($R^2=0.9843$) and 0.0216 ($R^2=0.9776$), respectively. Conclusions: Degradation of RhB in the electrochemical reactor with SPE can be achieved applying electrochemical oxidation. Supporting electrolyte has no positive effect on the final $UV_{254}$ absorbance and COD degradation. Mineralization of COD may take a relatively longer time than that of the RhB degradation.

NaCl 전해질 농도 변화에 따른 다공질 탄소전극의 전기적 특성 (Electrical Characteristics of Porous Carbon Electrode According to NaCl Electrolyte Concentration)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.814-819
    • /
    • 2010
  • Porous carbon electrodes with wooden materials are manufactured by molding carbonized wood powder. Electrical properties of the interface for electrolyte and porous carbon electrode are investigated from viewpoint of NaCl electrolyte concentration, capacitance and complex impedance. Density of porous carbon materials is 0.47~0.61 g/$cm^3$. NaCl electrolytic absorptance of the porous carbon materials is 5~30%. As the electrolyte concentration increased, capacitance is increased and electric resistance is decrease with electric double layer effect of the interface. The electric current of the porous carbon electrode compared in the copper and the high density carbon electrode was improved on a large scale, due to a increase in surface area. The circuit current increased as the distance between of the porous carbon electrode and the zinc electrode decreased, due to increase in electric field. Experimental results indicated that the current properties of galvanic cell could be improved by using porous carbon electrode.

Electrolyte 가 Bow-tie 형 수트리에 미치는 영향 (Effect of electrolyte on Bow-tie Water tree)

  • 강태오;양우영;김관성;전찬오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1550-1552
    • /
    • 1994
  • In order to investigate the effect of electrolyte solutions on the activities of bow-tie water trees in XLPE insulated power cable, we have tried to observe the characteristics on water treeing ( bow-tie type ) using several electrolyte solutions such as $CH_3COOH$, $MgCl_2$,HCl and NaCl solution and tap water. Bow-tie tree density in $CH_3COOH$ and $MgCl_2$ solution was higher than in any other solution, and the growth of tree was stimulated in NaCl and $CH_3COOH$ solution, and diffusion of bow-tie trees into insulation in $MgCl_2$, HCl and NaCl solutions was faster than in $CH_3COOH$ solution and water. Also, although the increase of applied voltage caused bow-tie tree density to be high, it didn't affect the growth of tree maximum length noticeably.

  • PDF

전기부상을 이용한 토양세정 유출수 처리에 관한 연구 : 전해질 및 pH의 영향 (A Study on the Treatment of Soil Flushing Effluent Using Electrofloatation : Effects of Electrolyte and pH)

  • 소정현;최상일;조장환
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권3호
    • /
    • pp.56-60
    • /
    • 2003
  • 전기분해에 의한 부상현상을 이용하여 유류로 오염된 토양 세정 후 발생되는 유출수 중 유분 등을 분리하기 위한 적정 운전조건을 찾고자 하였다. 전기분해 반응조(200${\times}$10${\times}$15cm)를 이용하여 혼합계면활성제($POE_5$ : $POE_{14} $, 1:1) 1%용액에 디젤을 1,000 mg/L 농도로 용해시켜 실험하였다. 양극에는 티타늄 코팅전극, 음극으로는 스테인레스 스틸전극을 이용하였다. 반응시간은 62분(반응 :60분, 부상시간 :2분)이었으며 전압은 6V였다. 전해질 첨가에 의한 영향을 알아보기 위하여 실험한 결과, 전해질을 첨가하였을 경우 첨가하지 않았을 때보다 40% 정도의 효율이 증가하였다. 적정 전해질, 주입농도 및 반응시간을 알아보기 위하여 1N NaCl과 NaOH의 농도를 변화시켜 가면서 실험하였다. NaCl의 경우 더 좋은 효율을 나타내었다. 전해질의 농도는 0.2-1.0%의 농도범위에서 NaCl와 NaOH 모두 농도에 따라 순차적으로 효율이 증가하였다. 두 전해질 모두 0.4-1.0% 농도 범위에서 평형에 도달하는 시간은 20분으로 나타났다.

PbO2 전극을 이용한 산화제 생성과 염료 Rhodaime B 제거 (Formation of Oxidants and Removal of Dye Rhodamine B using PbO2 Electrode)

  • 박영식
    • 한국물환경학회지
    • /
    • 제27권2호
    • /
    • pp.194-199
    • /
    • 2011
  • This study has been carried out to evaluate the performance of $PbO_2$ electrode for the purpose of degradation of N,N-Dimethyl-4-nitrosoaniline (RNO, indicator of OH radical), generation of ozone and decolorization of Rhodamine B (RhB) in water. The effect of the applied current (0.2~1.2 A), electrolyte type (NaCl, KCl and $Na_2SO_4$), electrolyte concentration (0.0~2.5 g/L) and solution pH (3~11) were evaluated. Experimental results showed that RhB and RNO removal were increased with the increase of current, NaCl dosage and decrease of pH. Ozone generation tendencies appeared with the almost similar to the RhB and RNO degradation, except of solution pH (Ozone generation was increased with increase of pH). Optimum current for RhB degradation and consumption of electric power was 1.0 A. The RhB degradation with Cl type electrolyte were higher than that with the sulfate type. Optimum NaCl dosage for RhB degradation was 1.0 g/L.

전기-펜톤 공정에 의한 페놀의 전기화학적 분해 (Electrochemical Degradation of Phenol by Electro-Fenton Process)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.201-208
    • /
    • 2009
  • Oxidation of phenol in aqueous media by electro-Fenton process using Ru-Sn-Sb/graphite electrode has been studied. Hydrogen peroxide was electrically generated by reaction of dissolved oxygen in acidic solutions containing supporting electrolyte and $Fe^{2+}$ was added in aqueous media. Phenol degradation experiments were performed in the presence of electrolyte media at pH 3. Effect of operating parameters such as current, electrolyte type (NaCl, KCl and $Na_2SO_4$) and concentration, $Fe^{2+}$ concentration, air flow rate and phenol concentration were investigated to find the best experimental conditions for achieving overall phenol removal. Results showed that current of 2 A, NaCl electrolyte concentration of 2g/l, 0.5M concentration of $Fe^{2+}$, air flow rate of 1l/min were the best conditions for mineralization of the phenol by electro-Fenton.