• Title/Summary/Keyword: Nan kyeong

Search Result 39, Processing Time 0.029 seconds

The study on the interrelationship of fixing the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse in front of Kwan(關) the distance of 1 Pun(分) and the development of the Kwan-Pulse(關脈) (기구인영맥(氣口人迎脈)의 '관전일분처(關前一分處)' 비정(比定)과 관맥(關脈) 형성과정(形成過程)의 상관성(相關性)에 관한 연구(硏究))

  • Kim, Jeong-Giu
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.2
    • /
    • pp.14-23
    • /
    • 2009
  • In the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse are the arterial pulsation position of the Lung Channel of Hand-Taeuem(手太陰) and the Stomach Channel of Foot-Yangmyeong(足陽明). At the pulses we can examine the circulation of Ki-Hyeol(氣血), the balance of Uem-Yang(陰陽), the deficiency and excess of the diseases, whether the disease is in Uem-Channel(陰經) or Yang-Channel (陽經), whether the disease is internel injury or externel injury. In the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse are in front of the Right-Kwan(右關) and the Left-Kwan(左關) the distance of 1 Pun(分) because of completion of the Chon-Ku-Pulse-Taking(寸口脈診). The purpose of examnation is same to . In the Kwan-Pulse(關脈) doesn't have the position. It has only the role of a gateway of the circulation of Ki-Hyeol(氣血), the balance of Uem-Yang(陰陽). And it is same to role of the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse in . So we can think that the Kwan-Pulse(關脈) in and the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse in are the same thing. And we must have the different standard when examine the condition of Sam-Cho(三焦) and the circulation of Ki-Hyeol(氣血), the balance of Uem-Yang(陰陽) because the position of the Kwan-Pulse(關脈) came out after the time of .

  • PDF

The study of pulse diagnosis(服診) about twelve meridians(十二經脈) (고대(古代)의 경복진단법(經服診斷法) 중 십이경맥(十二經脈) 맥진(脈診)에 관(關)한 연구(硏究))

  • Lim, Seong-cheol;Son, Seong-cheol;Lee, Kyung-min;Hwang, Min-seob;Kim, Kap-sung;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.19 no.5
    • /
    • pp.1-9
    • /
    • 2002
  • Objective : The study of relations between twelve meridians and pulse diagnosis Method : The possiblity of pulse diagnosis on the pulse points(脈動處) of each meridian through the scription of $\ll$Maek beop(脈法)$\gg$ $\ll$Nae kyeong(內經)$\gg$ and $\ll$Nan kyeong(難經$\gg$ Result : The comparative pulse diagnosis method(比較脈診法) in the scription of $\ll$Mack beop$\gg$ progressed to the five Jang bu maek(五臟脈) in the scription of $\ll$Young chu : Sa gi jang bu byeong hyeong(靈樞 邪氣臟腑病形)$\gg$ in accordance with the progress of pulse diagnosis and the theory of medicine. Conclusions : The comparative pulse diagnosis method in the scription of $\ll$Mack beop)$\gg$ progressed to the five Jang bu maek(五臟脈) in the scription of $\ll$Young chu : Sa gi jang bu byeong hyeong$\gg$ and the moxibustion and Pyum bup(貶法) in the scription of $\ll$Mack beop$\gg$ altered to acupuncture therapy on the five shu points(五輸穴)

  • PDF

Compact green light sources for laser projection display

  • Ko, Do-Kyeong;Jung, Chang-Soo;Yu, Nan-Ei;Yu, Bong-Ahn;Lee, Yeung-Lak;Lee, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1335-1336
    • /
    • 2008
  • A compact diode-pumped microchip(DPM) green light source which consist of pump LD, $Nd:YVO_4$, KTP and a built-in thermoelectric element has been fabricated for laser projection display. The volume of the source is as small as $0.7\;cm^3$ and we obtained the output power of 25mW with the average electric power consumption in pump LD of 304mW which correspond to the electrical-to-optical efficiency of 7.8%. Another approach using quasi phase matching(QPM) technique has been attempted. We obtained the output power of 90mW of green beam with 350mW pumping of a $Nd:YVO_4$ laser with 20-kHz rep. rate and 10-ns pulse duration. Detailed characteristics and issues of the DPM and QPM green light sources will be addressed.

  • PDF

Efficient Single-Pass Optical Parametric Generation and Amplification using a Periodically Poled Stoichiometric Lithium Tantalate

  • Yu, Nan-Ei;Lee, Yong-Hoon;Lee, Yeung-Lak;Jung, Chang-Soo;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.192-195
    • /
    • 2007
  • A high-conversion efficiency, nanosecond pulsed optical parametric generation and amplification with repetition rate of 20 kHz based on a periodically poled MgO-doped stoichiometric lithium tantalate was presented. Pumped by a Q-switched $Nd:YVO_4$ laser at 1064 nm with a pumping power of 4.8W, the generated output power was 1.6W for the signal and idler waves, achieving a slope efficiency of 50%. Using a seed source at signal wave the amplified signal output-pulse energy reached $65{\mu}J$. The obtained maximum gain was 72.4 dB.

Poling Quality Enhancement of PPLN Devices Using Negative Multiple Pulse Poling Method

  • Choi, Ju-Won;Ro, Jung-Hoon;Ko, Do-Kyeong;Yu, Nan-Ei
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.182-186
    • /
    • 2011
  • A poling method using multiple negative voltage was introduced to fabricate periodically poled lithium niobate (PPLN) devices with quasi-phase matching (QPM) period of $12.9\;{\mu}m$ by utilizing an real-time visualization system. We also performed variation of the electric field during the poling. Two different conventionally used poling method, negative and positive single pulses, were used and the poling quality compared through microscopic images and far-field diffraction pattern analysis. Etched images on the +z and -z surfaces of PPLN showed that negative multiple pulse poling presented the highest periodicity in domain structures among the three methods. Duty ratio and its standard deviation were measured by analyzing far-field diffraction patterns. The newly introduced method of negative multiple pulse poling had duty ratio of 0.42 which was close to the ideal value of 0.50 and standard deviation of 0.020 that was about 3 times smaller than that of the other conventional methods.

2-Substitiuted Thio- and Amino-5,8-dimethoxy-1,4-naphthoquinones as a Novel Class of Acyl-CoA: Cholestrol Acyltransferase Inhibitors

  • Shen, Gui-Nan;Choi, Jung-Ho;Gajulapati, Kondaji;Lee, Jee-Hyun;Kim, Young-Kook;Rho, Mun-Chal;Jung, Sang-Hun;Lee, Kyeong;Han, Sung-Sik;Song, Gyu-Yong;Choi, Yong-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1088-1092
    • /
    • 2009
  • A series of 2-alkyl or 2-arylthio-5,8-dimethoxy-1,4-naphthoquinones (2-Thio-DMNQ, 5a-s) and 2-alkylamino-5,8- dimethoxy-1,4-naphthoquinones (2-Amino-DMNQ, 6a-k) was synthesized and evaluated for their ACAT inhibitory activities. Among them, the 2-dodecylthio-DMNQ 5l and 2-isobutylamidoundodecylthio-DMNQ 5r showed the most potent ACAT inhibitory activities with $IC_{50}$ value of 22.8 and 24.4 ${\mu}M$, respectively. In a structure-activity relationship study, 2-thio-DMNQs with side chains of carbon number 11 $\sim$ 15 exhibited significant ACAT inhibitory activities.

Temperature and Stress Analysis of Box Culvert in Fire (화재에 의한 지하공동구의 온도 및 응력해석)

  • Kim, Hyun-Jun;Im, Cho-Rong;Yoo, Hyeon-Kyeong;Chung, Chul-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.31-44
    • /
    • 2011
  • This paper has presented a finite element analysis of structural behaviour of box culvert during and after fires. The fire tests were carried out in a furnace on RC slabs using the ISO 834 standard fire curve. The load capacity after cooling of the RC slab that was not loaded during the fire tests was evaluated by means of additional 3 points bending tests. In the past, stress-strain models of concrete under fire loading have been proposed by several researchers. Comparisons are made with the load-displacement relations of RC slabs after fire loading using the existing stress-strain models with temperature, such as Schneider, EUROCODE 2, Lie, Shi and Nan model. By comparing the load-displacement relations, Lie model was found to result in a maximum load about 2.0% higher than that of test. Based on the fire test results of RC slabs, this paper presents an extensive analytical study on the fire response of box culvert during and after fires.

Bus-waveguide-width Dependence of Evanescent Wave Coupling in a Microring Resonator

  • Son, Seong-Jin;Kim, Suyeon;Yu, Nan Ei;Ko, Do-Kyeong
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.538-543
    • /
    • 2021
  • The evanescent wave coupling of a microring resonator is controlled by changing the gap distance between the bus waveguide and the microring waveguide. However, the interdependence of the bus waveguide's width and the coupling is not well understood. In this paper, we investigate the dependence of coupling strength on the bus waveguide's width. The strength of the evanescent wave coupling is analytically calculated using coupled-mode theory (CMT) and numerically calculated by three-dimensional finite-difference-time-domain (FDTD) simulation. The analytic and numerical simulation results show that the phase-matching condition in evanescent wave coupling does not provide maximum coupling strength, because both phase-matching and mode confinement influence the coupling. The analytic and simulation results for the evanescent coupling correspond to the experimental results. The optimized bus-waveguide width that provides maximum coupling strength results in intrinsic quality factors of up to 1.3 × 106. This study provides reliable guidance for the design of microring resonators, depending on various applications.