• Title/Summary/Keyword: Neutral

Search Result 5,921, Processing Time 0.038 seconds

NEUTRAL SUBTRACTION ALGEBRAS

  • KIM, YOUNG HEE;ROH, EUN HWAN
    • Honam Mathematical Journal
    • /
    • v.28 no.1
    • /
    • pp.23-29
    • /
    • 2006
  • Neutral subtraction algebras and neutral ideals are introduced, and related properties are investigated.

  • PDF

A Study on Neutral Atom Heating in Inductively Coupled Plasma

  • Seo, Byeong-Hun;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.178-178
    • /
    • 2012
  • Neutral atom temperature was measured by Laser Rayleigh scattering method using neutral depletion by neutral heating with ideal gas law in Inductively coupled plasma. We observed sudden pressure change when plasma is turned on and off. We analyzed mechanism of neutral heating by employing zero-dimensional neutral and ion energy balance model simultaneously. The results showed that neutral atom temperature increase with ion density. The mechanism of neutral atom heating and cooling is mainly dominated by ion-neutral collision including elastic and charge-exchange collision and by wall cooling respectively.

  • PDF

Theoretical Study of Neutral Section Considering the Driving Characteristics of ATO Urban Railway Vehicle (자동운전 도시철도차량의 운전특성을 고려한 절연구분장치 이론적 고찰)

  • Lee, Jae-Bong;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1470-1474
    • /
    • 2013
  • In this paper, proper length of neutral section and neutral section system configuration is proposed to minimize accidents if ATO urban railway vehicle stops maintaining the leading vehicles in air section at regular intervals. When considering the minimum voltage sensing of power conversion unit in the urban railway vehicle, the effective length of 14,280[mm] with neutral section can be minimized damage due to high current because the urban railway vehicle is very little present chance compare neutral section with pantograph interval installed on a unit vehicle. In addition, uplift of catenary line and contact wire consider to minimize damage. The result of theoretical review, as the proposed neutral section shorter, isolated neutral section is effective than the integrated neutral section.

A Small Signal Modeling of Three-level Neutral-Point-Clamped Inverter and Neutral-Point Voltage Oscillation Reduction (3레벨 NPC인버터의 소신호 모델링과 중성점 전압 진동 저감)

  • Cho, Ja-Hwi;Ku, Nam-Joon;Joung, Seok-Eon;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.407-414
    • /
    • 2014
  • This study proposes a control design for the grid output current and for reducing the neutral-point voltage oscillation through the small-signal modeling of the three-phase grid connected with a three-level neutral-point-clamped (NPC) inverter with LCL filter. The three-level NPC inverter presents an inherent problem: the neutral-point voltage fluctuation caused by the neutral-point current flowing in or out from the neutral point. The small signal modeling consists of averaging, dq0 transformation, perturbing, and linearizing steps performed on a three-phase grid connected to a three-level NPC inverter with LCL filter. The proposed method controls both the grid output and neutral-point currents at every switching period and reduces the neutral-point voltage oscillation. The validity of the proposed method is verified through simulation and experiment.

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

Coarticulation and vowel reduction in the neutral tone of Beijing Mandarin

  • Lin Maocan
    • Proceedings of the KSPS conference
    • /
    • 1996.10a
    • /
    • pp.207-207
    • /
    • 1996
  • The neutral tone is one of the most important distinguishing features in Beijing Mandarin, but there are two completely different views on its linguistic function: a special tone(Xu, 1980) versus weak stress(Chao, 1968). In this paper, the acoustic manifestation of the neutral tone will be explored to show that it is closely related to weak stress. 122 disyllabic words in which the second syllable carries the neutral tone, including 22 stress pairs, were uttered by a native male speaker of Beijing dialect and analysed by Kay Digital Sonagraph 5500-1. The results of the acoustic analysis are presented as follows: 1) The first two formants of the medial and the syllabic vowel moves towards that of central vowel with a greater magnitude in the syllable with the neutral tone than in the syllable with any of the four normal tones. Also the vowel ending, and nasal coda /n/ and / / in the syllable with the neutral tone tends to be deleted. 2) In the syllables with the neutral tone, there are strong carryover coarticulations between the medial and syllabic vowel and the preceding unvoiced consonant. In general, the vowel is affected to move towards the position of the central vowel with more greater magnitude by coronal consonant than by labial or velar consonant. 3) In the syllable with the neutral tone, when and only when it precedes a syllable with tone-4, the high vowel following [f], [ts'], [s], [ts'], [s], [tc'] or [c] tends to be voiceless. 4) It can be seen from the acoustical results of 22 stress pairs that the duration of the syllable with the neutral tone is on the average reduced to 55% of that of the syllable with the four normal tones, and the duration of the final in the syllable with neutral tone is on the average reduced to 45% of that of the final in the syllable with the four normal tones(Lin & Yan 1980). 5) The FO contour of the neutral tone is highly dependent on the preceding normal tone(Lin & Yan 1993). For a number of languages it has been found that the vowel space is reduced as the level of stress placed upon the vowel is reduced(Nord 1986). Therefore we reach the conclusion that the syllable with neutral tone is related to weak stress(Lin & Yan 1990). The neutral tone is not a special tone because the preceding normal tone.

  • PDF

Neutral Deinking of Mixed Office Wastepaper (Mixed Office Wastepaper의 중성탈묵)

  • 윤병태;오세균
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.2
    • /
    • pp.50-57
    • /
    • 1999
  • This study was carried out to compare a conventional alkaline flotation deinking conditions with neutral deinking conditions with and without enzyme addition with respect to the ink removal efficiency and theflotation deinking filtrate quality such as chemical oxygen demand, cationic demand, suspended solids. Based on ink removal rate the neutral deinking condition without enzyme was better than the alkaline deinking condition, and the neutral deinking with enzyme addition turned out to be the best. The brightness of the deinked pulp was found to be the same trend as the ink removal rate. Flotation reject rate for the neutral deinking condition without enzyme was higher than that of the alkaline deinking condition, but that of the neutral deinking condition with enzyme was lower than that of the alkaline and the neutral deinking condition without enzyme. On the freeness of the deinked pulp, the neutral deinking condition with enzyme had the highest value and the alkaline deinking condition had the lowest value among the conditions tested. On the filtrate of the flotation stage, the cationic polymer demand of the neutral deinking condition with enzyme was much lower than the other conditions. Suspended solids and chemical exygen demand for the neutral flotation deinking filtrate was lower than those of the alkaline flotation deinking filtrate.

  • PDF

A Neutral-Point Voltage Balance Controller for the Equivalent SVPWM Strategy of NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2109-2118
    • /
    • 2016
  • Based on the space vector pulse width modulation (SVPWM) theory, this paper realizes an easier SVPWM strategy, which is equivalently implemented by CBSPWM with zero-sequence voltage injection. The traditional SVPWM strategy has no effect on controlling the neutral-point voltage balance. In order to solve the neutral-point voltage unbalance problem for neutral-point-clamped (NPC) three-level inverters, this paper proposes a neutral-point voltage balance controller. The proposed controller realizes controlling the neutral-point voltage balance by dynamically calculating the offset superimposed to the three-phase modulation waves of an equivalent SVPWM strategy. Compared with the traditional SVPWM strategy, the proposed neutral-point voltage balance controller has a strong ability to balance the neutral-point voltage, has good steady-state performance, improves the output waveforms quality and is easy for digital implementation. An experiment has been carried out on a NPC three-level inverter prototype based on a digital signal processor-complex programmable logic device (DSP-CPLD). The obtained experimental results verify the effectiveness of the proposed neutral-point voltage balance controller.

Analysis of Average Neutral Point Current in 3-level NPC Converter under Generalized Unbalanced AC Input Condition

  • Jung, Kyungsub;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.151-152
    • /
    • 2016
  • This paper presents a neutral point deviation compensating control algorithm applied to a 3-level NPC converter under generalized unbalanced ac input conditions. The neutral point deviation is analyzed with a focus on the current flowing out of or into the neutral point of the dc-link in 3-level NPC converter. The model of neutral point deviation and neutral current are also constructed. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converter and its impact on neutral point deviation. This paper includes the harmonic characteristic of neutral point current under various imbalance AC operating conditions.

  • PDF

Neutral Deinking of Old Newsprints Contaminated with Flexo Ink -Evaluation of the Deinking Efficiency of Two Neutral Deinking Agents- (플렉소 잉크가 포함된 신문고지의 중성 탈묵 -중성 탈묵제의 효율 평가-)

  • Lee, Hak-Lae;Ryu, Hoon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.1
    • /
    • pp.8-15
    • /
    • 2001
  • Presence of small amount of old newsprints printed with waterbased flexographic inks leads to a significant loss brightness of the deinked pulp by flotation process. Recently there has been an increased interest in employing neutral deinking processes to solve the problems associated with waterbased flexo ink. A comparative experimental study was performed to evaluate the efficiency of neutral deinking and conventional alkaline deinking for ONP furnishes contaminated with flexo ink. It was shown that neutral deinking provides significant improvements in brightness, yield and freeness as compared with alkaline deinking. Flotation efficiency was different depending upon the type of surfactants used in neutral deinking. The result of this study showed that alcohol type surfactant is superior to fatty acid type surfactant in neutral deinking efficiency.

  • PDF