• Title/Summary/Keyword: Neutral pressure level

Search Result 19, Processing Time 0.025 seconds

Development of a Natural Ventilation Model in a Single Zone Building with Large Openings (큰 개구부를 가진 단일구획 빌딩에서의 자연환기 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.359-369
    • /
    • 2018
  • A model has been developed to predict natural ventilation in a single zone building with large openings. This study first presents pressure-based equations on natural ventilation, that include the combined effect of wind and thermal buoyancy. Moreover, the concept of neutral pressure level(NPL) is introduced to consider the two-way flow through a large opening. The total pressure differences across the opening and the NPL are calculated, and nonlinear equations are solved to find the zonal pressure to satisfy mass conservation. For this analysis, an iterative technique of successively approximating the zonal pressure is used. The results of applying this study model to several simple cases are as follows. When there is no wind and only the stack effect is caused, a one-way flow occurs in both the top and bottom openings in the case of two openings of equal-area, and a one-way flow occurs in the top opening; however, a two-way flow occurs in the bottom opening in the case of two openings of unequal-area. When there is a wind effect, regardless of whether the outside air temperature is lower or higher than the indoor air temperature, air flows into the room through the bottom opening and out of the room through the top opening. As the wind velocity increases, the wind effect appears to be more influential than the stack effect owing to the temperature difference.

The Effects of Foot Placement and Lifting on Lower Extremity Muscle Activity and Foot Pressure During Sit to Stand in Hemiparetic Patients (뇌졸중 환자의 물건 들고 일어서기 동작이 하지근 활동도 및 족저압에 미치는 영향)

  • Kim, Hee-Tag;Lim, Wan-Sang
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.3_4
    • /
    • pp.29-39
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effect of foot position and lifting an object on muscle activity and foot pressure during sit to stand(STS) in hemiparetic patients. Methods: Fourteen patients participated in this study. Surface electromyography was used to collect muscle activity and foot pressure measurement system was used to analyze foot pressure in hemiparetic side. Three different foot position was assumed(anterior, neutral, posterior) in hemiparetic side. The repeated two-way analysis of variance and multiple comparisons were conducted to determine statistical significance with a significance level of 0.05. Results: The results were as follows. 1) Lower extremity muscle activity was significantly higher(p<0.05) in biceps femoris and tibialis anterior muscle during STS without holding an object. With changing positions of the affected foot, muscle activity was significantly increased (p<0.05) in vastus medialis and lateral gastrocnemius when the foot was positioned in posterior. 2) There was no significant difference(p>0.05) in foot pressure during STS with object holding and foot positioning. Conclusion: Muscle activity showed a significant increase when the foot was positioned in posterior in comparison to the muscle activity when the foot was in neutral or anterior position.

  • PDF

Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket (흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • The study was explored socket pressure distributions on a trans-femoral amputee with a suction socket in static and dynamic situations. Even when the amputee stood in the anatomically neutral position, significant pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free level walking, a significant shifting pattern of pressure concentration areas was observed. High socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.

  • PDF

Modeling the Chemical Kinetics of Atmospheric Plasma

  • Kim, Ho-Yeong;Lee, Hyeon-U;Kim, Gyu-Cheon;Lee, Jae-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.270-270
    • /
    • 2012
  • Low temperature atmospheric pressure plasmas (APPs) have been known to be effective for living cell inactivation in the water [1]. Many earlier research found that pH level of the solution was changed from neutral to acidic after plasma treatment. The importance of the effect of acidity of the solution for cell treatments has already been reported by many experiments. In addition, several studies have demonstrated that the addition of a small amount of oxygen to pure helium results in higher sterilization efficiency of APPs [2]. However, it is not clear yet which species are key factors for the cell treatment. To find key factors, we used GMoo simulation. We elucidate the processes through which pH level in the solution is changed from neutral to acidic after plasma exposure and key components with pH and air variation with using GMoo simulation. First, pH level in a liquid solution is changed by He+ and He(21S) radicals. Second, O3 density decreases as pH level in the solution decreases and air concentration decreases. It can be a method of removing O3 that cause chest pain and damage lung tissue when the density is very high. H2O2, HO2 and NO radicals are found to be key factors for cell inactivation in the solution with pH and air variation.

  • PDF

Association Study between Serum Uric Acid Level and Metabolic Syndrome (혈청 요산 농도와 대사증후군과의 연관성에 대한 연구)

  • Park, Duk-Hyun;Lee, Eun-Ryeong;Ju, Joung-Youl
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.2
    • /
    • pp.38-46
    • /
    • 2017
  • This research aimed to identify the correlation between the metabolic syndrome, which is one of the cardiovascular risk factors and emerging as an issue in the society, and the serum uric acid level. The research was conducted on a total of 1,444 patients who took a medical examination at a health examination center. The research subjects were composed of 977 men and 467 women. By conducting physical measurement and the blood test on the subjects, the research identified the correlation between the serum uric acid level and the metabolic syndrome and compared the number of the risk factors by dividing the class of the serum uric acid. The average level of serum uric acid was identified higher in men at $6.30{\pm}1.39mg/dL$ than $4.43{\pm}0.89mg/dL$ in women. Men had a correlation between age, waist size, systolic blood pressure, neutral fat, HDL-cholesterol, WBC count and ESR and the serum uric acid level (p<0.05), while women had a correlation between waist size, diastolic blood pressure level, neutral fat, HDL-cholesterol and ESR and the serum uric acid level (p<0.05). The number of the risk factors depending on the serum uric acid level increased as the serum uric acid level rose. The overall prevalence rate of the metabolic syndrome was higher in men at 17.4% than 10.2% in women. This showed that there is a statistically relevant relevance between the metabolic syndrome and the serum uric acid level, and the number of the risk factors of the metabolic syndrome will go up with an increase in the serum uric acid level.

Wind Castle: The Natural Intelligence Control of Hallasan-Oreum-Batdam I (윈드캐슬: 한라산-오름-밭담의 자연지능 제어 I)

  • Lee, Moon-Ho;Kim, Jeong-Su
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.105-111
    • /
    • 2020
  • We defined Jeju Wind Castle and analyzed the relationship between Hallasan-Oreum-Batdam, the main subject, for the first time. In Jeju, 1.5m high Batdam(Black Silk Road), 368 Oreums, Hallasan Mountain 1950m are all unique scenery. The verification of this paper demonstrates that Samdasoo's groundwater extraction sea level is equal to the height of Hallasan and that this problem is mathematically complete in neutral plane theory. Donnaeko(700meters above sea level)-Baeknokdamdongneung-Jindallebat-Seongpanak-Gyorae(453 meters)-Witsaeoreum(1700meters) is a rain belt that hits the low-air pressure air-conditioned North Pacific humidity rising from the southeast and the high-pressure cold air of Hallasan Peak. It rains a lot because - and + are neutral plane, which adds to zero. Hallasan is called Jinsan in Jeju history. The answer is Wind Castle. The number of Oreum in Jeju is 369 including Hallasan, and Batdam, which is about 1.5m high, does not collapse even with a typhoon blowing over 50m/s. Because the wind castle's core is 1.5 meters of Batdam and it is a triangular number.

Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study (실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결)

  • Koo Sung-Han;Jo Jae-Hun;Yeo Myoung-Souk;Kim Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

Electron Spin Resonance from Mg-doped GaN Semiconductor Thin Films (Mg도핑된 GaN 반도체 박막의 전자스핀공명)

  • Park, Hyo-Yeol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.1-5
    • /
    • 2005
  • Electon spin resonance measurements have been performed on the Mg-doped wurtzite GaN thin films grown on sapphire substrates by low-pressure metal-organic chemical vapor deposition. The sample set included films as-grown with the regular Mg doped and Mg delta doped samples and the corresponding annealed ones. The resonance signal has been observed from the annealed Mg delta-doped sample with the Lande g value of 2.029. This indicates that the singlet resonance signal originates from the neutral Mg acceptor located at 0.24 eV above the valence band edge and 0.13 eV above the Fermi level because of the nuclear hyperfine spin 1=0 of Mg and the larger value than the free electron g=2.0023.

  • PDF

Study on the Control Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층공동주택 국소배기용 입상덕트시스템의 제어성능평가에 관한 연구)

  • Kwon, Yong-Il;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2009
  • Local exhaust system used in toilet and cooking place of low-rise public house installed roof ventilator at terminal of stack. There are many high riser public houses in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser public house depends on stack effect. But Neutral pressure level represents in a terminal of stack with air tightness for the best exhaust efficiency. Thereby, lower floors have the worst indoor air quality. This paper focuses mainly on the exhaust efficiency improved by roof fan with motor installed in high riser public house. It is observed there is higher exhaust efficiency than the existing natural roof ventilator.

Analysis of the February 2014 East Coast Heavy SnowFall Case Due to Blocking (블로킹에 의한 2014년 2월 동해안 지방 폭설 분석)

  • Bae, Jeong-Ho;Min, Ki-Hong
    • Atmosphere
    • /
    • v.26 no.2
    • /
    • pp.227-241
    • /
    • 2016
  • This study investigated the cause of the heavy snowfall that occurred in the East Coast of Korea from 6 February to 14 February 2014. The synoptic conditions were analyzed using blocking index, equivalent potential temperature, potential vorticity, maritime temperature difference, temperature advection, and ground convergence. During the case period, a large blocking pattern developed over the Western Pacific causing the flow to be stagnant, and there was a North-South oriented High-to-Low pressure system over the Korean Peninsula because of this arrangement. The case period was divided into three parts based on the synoptic forcing that was responsible for the heavy snowfall; detailed analyses were conducted for the first and last period. In the first period, a heavy snowfall occurred over the entire Korean Peninsula due to strong updrafts from baroclinic instability and a low pressure caused by potential vorticity located at the mid-troposphere. In the lower atmosphere, a North-South oriented High-to-Low pressure system over the Eastern Korea intensified the easterly airflow and created a convergence zone near the ground which strengthened the upslope effect of the Taebaek Mountain range with a cumulative fresh snowfall amount of 41 cm in the East Coast region. In the last period, the cold air nestled in the Maritime Province of Siberia and Manchuria strengthened much more than that in the first half and extended to the East Sea. The temperature difference between the 850 hPa air and the SST was large and convective clouds developed over the sea. The highest cumulative fresh snow amount of 39.7 cm was recorded in the coastal area during this period. During the entire period, vertically oriented equivalent potential temperature showed neutral stability layer that helped the cloud formation and development in the East Coast. The 2014 heavy snowfall case over the East Coast provinces of Korea were due to: 1) stagnation of the system by blocking pattern, 2) the dynamic effect of mid-level potential vorticity of 1.6 PVU, 3) the easterly air flow from North-South oriented High-to-Low pressure system, 4) the existence of vertically oriented neutral stable layer, and 5) the expansion of strong cold air into the East Sea which created a large temperature difference between the air and the ocean.