• Title/Summary/Keyword: Nitrocellulose

Search Result 104, Processing Time 0.031 seconds

A Study on the High Purity Separation of Nitrocellulose from 175mm Ammunition Propellant (175mm 포탄추진제로부터 nitrocellulose의 고순도 분리에 관한 연구)

  • Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.290-295
    • /
    • 2015
  • The purpose of this study is to separate nitrocellulose from 175 mm ammunition propellant by environmentally responsible recovery method. Recovery of nitrocellulose from obsolete ammunition is much more desirable than destruction since it can be reused in the several purpose. In spite of durable demilitarization of obsolete ammunition, the current holding amount of obsolete ammunition is gradually increasing and accumulated. The existing demilitarization methods, such as incineration and priming are strictly restricted for the noise, dust, oscillation and air and soil pollution. This study is focused on the separation of nitrocellulose by environmentally responsible recovery method by the solubility difference of nitrocellulose in nonpolar solvent. The purity of an extracted nitrocellulose was analysed by IR and TLC method and was clarified as very high.

NOx Gas Detecting Properties of the Nitrocellulose/MWCNT Thin Film Coated on the Glass Substrate (유리 기판 위에 제작된 Nitrocellulose/MWCNT 박막의 질소가스 검출특성)

  • Lee, Won Jae;Choi, Myung Kyu;Jang, Kyung Uk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.55-59
    • /
    • 2012
  • NOx is one of the toxin gases, which is mainly causing the optic-chemical smog phenomena, and decreasing in the function of nose and taste. Especially, NO is easily reacting with $O_3$, and then becoming the $NO_2$. $NO_2$ is mainly causing the acidulation rain. So, we should develop the NOx gas sensing system to detect NOx gas. In this paper, we present the microstructure and the NOx gas detecting properties of the nitrocellulose/MWCNT thin film coated by the air-spray on the glass substrate. The nitrocellulose/MWCNT-based gas sensors have been studied detecting NOx molecules of a ppm-level at the temperature range of $30{\sim}120^{\circ}C$. The resistance of the sensors decreases when the sensors are exposed to NOx gas. As a results, we obtained the nitrocellulose/MWCNT sensors with the sensitivity of 0.6%/sec under the 0.8 ppm of NOx gas concetration. Also, we get the activation energy of 0.202eV from the sensor for the 0.3 ppm of NOx gas concentration.

Transfer of RNA from Methylmercury-agarose Gel to Nitrocellulose Membrane (메칠머큐리젤에 분리된 리보핵산의 니트로셀루로스막으로 이동)

  • 안정선
    • Journal of Plant Biology
    • /
    • v.30 no.2
    • /
    • pp.109-116
    • /
    • 1987
  • Effects of staining, buffer washing and denaturing agents on the transferrability of RNA fractionated on a methylmercury hydroxide-agarose gel to a nitrocellulose membrane were studied. Ethidium bromide staining and ammonium acetate buffer washing inhibited RNA transfer, while 3% HCHO and 0.5 M NaOH treatments stimulated transfer which was negated in the ammonium acetate buffer. Accordingly, maintenance of primary structure of RNA was proved to be essential for transferring RNA from the methylmercury hydroxideagarose gel to the nitrocellulose membrane.

  • PDF

The Properties of the Nitrocellulose/MWCNT Composites Fabricated on the 10 ${\mu}m$ Polyimide Film for the Flexible Transparent Conduction Film (10 ${\mu}m$ 폴리이미드 기판에 성막된 플렉시블 투명 전도막용 Nitrocellulose/MWCNT 복합체의 제작 및 특성)

  • Jang, Kyung-Uk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • The composite films were fabricated by air-spray method under the 2 kgf/$cm^2$ pressure using the multi-walled CNTs solution and the nitrocellulose on a 10 ${\mu}m$ polyimide film substrates. We obtained the composite films which were sprayed with the MWCNT dispersion by varying the spray time from 20, 40 and 60sec. The electrical and the optical properties of the sandwiched-structure-composite thin films were investigated by an UV/VIS spectrometer and a Hall Effect equipment. As a result, the optical transmittance of all thin films in the visible range, as well as the electrical conductance shows an available value for the transparent electrode. The carrier concentration and the light transmittance rate for the fabricated sample are between $3.733{\times}10^{10}$ and $6.551{\times}10^{14}cm^{-3}$, around 35 to 95%, respectively.

Multi-step Reactions on Microchip Platform Using Nitrocellulose Membrane Reactor

  • Park, Sung-Soo;Joo, Hwang-Soo;Cho, Seung-Il;Kim, Min-Su;Kim, Yong-Kweon;Kim, Byung-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.257-262
    • /
    • 2003
  • A straightforward and effective method is presented for immobilizing enzymes on a microchip platform without chemically modifying a micro-channel or technically microfabricating a column reactor and fluid channel network. The proposed method consists of three steps: the reconstitution of a nitrocellulose (NC) membrane on a plane substrate without a channel network, enzyme immobilization on the NC membrane, and the assembly of another substrate with a fabricated channel network. As a result, enzymes can be stably and efficiently immobilized on a microchip. To evaluate the proposed method, two kinds of enzymatic reaction are applied: a sequential two-step reaction by one enzyme, alkaline phosphatase, and a coupled reaction by two enzymes, glucose oxidase and peroxidase, for a glucose assay.

A Study of Life about Naturally Aged Nitrocellulose by Storage (자연 노화된 니트로셀룰로오스의 수명에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.595-601
    • /
    • 2020
  • During the safety inspection of nitrocellulose-made explosive containers stored for more than 10 years, cracks were found in the containers. Therefore, a failure cause analysis test was performed. First, the cause of failure through the failure tree analysis was conducted to select the factors that influenced failure. The changes in the properties of the container caused by the acceleration of the reaction were found to be the cause of the failure by confirming the influence on the environment and internal/external factors that may occur during storage. To confirm this, environmental tests, such as thermal shock test and vacuum thermal stability test, were performed using a naturally aged container to analyze the cause of failure, and an accelerated aging test was performed to reproduce the failure. Through this, the chemical reaction was accelerated by heat and charge, as in the result of the fault tree analysis, and it was confirmed that the physical properties of the container were changed. In addition, the service life of the container was estimated using the Arrhenius model for the storage life due to thermal aging.

Studies on the Cracking of Nitrocellulose Clear Lacquer Coasted Films on Solid Woods of Quercus acutissima and Betula platyphylla var. japonica (상수리나무와 자작나무 소재(素材)에 대한 Nitrocellulose Clear Lacquer 도막(塗膜)의 할열(割裂)에 관(關)한 연구(硏究))

  • Kim, Hyun-Joong;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.55-68
    • /
    • 1989
  • This experiment was carried out to investigate the crack of coated Nitrocellulose Lacquer on flatand edge-grained boards of Quercus acutissima, ring-porous wood, and Betula platyphylla var. japonica, diffuse-porous wood, by variations of moisture contents at 7, 13 and 21%. Cold check system was used as an accelerating method for crack development, in which one cycle of the system consisted of 10 replications of each unit cycle, $60^{\circ}C$ for 4hr followdd by $-20^{\circ}C$ for 4hr. The analysis of Nitrocellulose Lacquer characteristics was made by means of water permeation measurement, F.T.I.R. spectroscopy, N.M.R. spectroscopy, gel permeation chromatography, gas chromatography, and D.S.C. The results obtained were as follows: 1. The number of cracks increased with the increasing moisture content of board. 2. The crack of coated film on flat-grained board was fewer in number than on edge-grained board. 3. The crack occurred in Quercus acutissima was more numerous on edge-grained board but less frequent on flat-grained board compared with that in Betula platyphylla var. japonica, respectively. 4. The cold crack vertically developed to the grain both in Quercus acutissima and Betula platyphylla var. japonica. 5. Water permeability in intermediate coated film was lower than in under and top coated film, but the difference was not confirmed between under and top coated film.

  • PDF

Efficient Biotinylation of Nitrocellulose Membrane for Immuno-Filtration Capture Assay

  • Choi, Ki-Bong;Ha, Youn-Chul;Youn, Hee-Ju;Choi, Jung-Do
    • BMB Reports
    • /
    • v.30 no.5
    • /
    • pp.308-314
    • /
    • 1997
  • We investigated biotinylation of nitrocellulose membrane for immuno-filtration capture assay. In order to enhance the efficiency of biotinylation, nitrocellulose membranes were pretreated with several chemicals for the purpose of suitable protein absorption through surface modification. As a signal generating enzyme, urease was used and the concentration of avidin was optimized for the efficient binding kinetics between urease-biotin in liquid phase and biotinylated membrane in solid phase. For effective biotinylation, bovine serum albumin-biotin complexes could be immobilized at a concentration of $370\;{\mu}g$/stick ($4.4\;cm^2$). Among tested chemicals, polylysine (0.25%) showed a significant effect in biotinylation. Polylysine is thought to enhance surface area by extending unbound residues into solution. Time of treatment over 30 min and higher molecular weight of polylysines (58,100 dalton) showed positive effect on the enhancement of biotinylation. The result from this study may be useful for developing a new biosensor and other biofunctional membranes for examining molecular recognition.

  • PDF

A study on the self-life estimation of the propellant KM10 by using high temperature acceleration aging tests (고온가속노화시험을 이용한 추진제 KM10의 저장 수명 추정)

  • Cho, Ki-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1735-1740
    • /
    • 2010
  • The propellant KM10, a single propellant manufactured nitrocellulose, is known to cause natural degradation phenomena at long term storage. The self-life was estimated using generally used high temperature acceleration aging tests to analyze the content of stabilizer and using the Arrhenius equation & Berthelot equation to calculate reaction rate constants. According to the result of this study, self-life of propellant KM10 using the Arrhenius equation & Berthelot equation appear significantly different as 43.73, 16.53years and when compared with the paper of E. R. Bixon, self-life of propellant KM10 predicted using the Arrhenius equation was reasonably determined.

Sensing Properties of Hydrogen Gas for the MWCNT Thin Film Sprayed on the Glass Substrate Cured with Plasma and Nitrocellulose (플라즈마 및 니트로셀롤로우스로 처리된 유리기판을 사용한 MWCNT 스프레이 박막의 수소가스 검출특성)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.290-296
    • /
    • 2011
  • Carbon nanotubes (CNTs) have excellent electrical, chemical stability, mechanical and thermal properties. In this paper, networks of Multi-walled carbon nanotube (MWCNT) materials were investigated as a resistive gas sensors for the $H_2$ gas detection. Sensor films were fabricated by the air spray method using the multi-walled CNTs dispersion solution on the glass substrates cured with plasma and nitrocellulose. Sensors were characterized by the resistance measurements in the self-fabricated oven in order to find the optimum detection properties for the hydrogen gas molecular. The sensitivity and the linearity of the MWVNT sensors using the glass substrate cured with plasma for the $H_2$ gas concentration of 0.06~0.6 ppm are 0.013~0.097%/sec and 0.131~0.959%FS, respectively. The MWCNT film was excellent in the response for the hydrogen gas moleculars and its reaction speed was very fast, which could be using as hydrogen gas sensor. The resistance of the fabricated sensors decreases when the sensors are exposed to $H_2$ gas.