• 제목/요약/키워드: Non-contact method

검색결과 826건 처리시간 0.03초

광섬유 센서를 이용한 지폐 계수 장치에 관한 연구 (A Study of the Non-Contact Bill Counter using Optical Fiber Sensor)

  • 강대화;신우철;송두상;장탁순;홍준희
    • 한국공작기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.231-236
    • /
    • 2007
  • In this paper, we studied the possibility of non-contact bill counting method using optical fiber sensor instead of traditionally used friction counting method. To implement non-contact counting, we designed and made optical fiber sensor and related parts. optical fiber sensor is made of optical fiber of 1mm diameter, photo diode and laser diode. Based on the conclusion which derived from preliminary experiment, instrument part is designed to make unevenness on the surface of bill paper and to stay parallel with optical fiber section. By analyzing the signal of optical sensor, we made counting program. Experimental instrument is composed of sensor part, instrument part, signal handling part. We checked the possibility of non-contact counting method after implementing experiment by using optical fiber sensor and instrument part.

비접촉 ID카드 계수를 위한 자동화 시스템 개발 (Study on Development of Automation System for Non-Contact Counting of ID Card)

  • 강대화;홍준희;곽양양;이혁원
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.652-657
    • /
    • 2013
  • In this study, we developed a counting method for non-contact ID cards using an optical fiber displacement sensor instead of the traditionally used friction counting method. The proposed method has the advantage of high speed and automated measurement. For counting non-contact ID cards, an H-type optical fiber sensor, jig part, and counting program are developed separately to build the system and adjust it. Through the experimental test results, it was confirmed that counting is possible with one type of international ID card and one type of financial security card based on ISO7810. Furthermore, by applying the proposed method to 100 ID cards 100 times repeatedly, it was confirmed that it has high accuracy and an error ratio of 0%. We experimentally demonstrated that the proposed counting method for non-contact ID cards using an optical fiber displacement sensor can perform measurements with high accuracy and high speed.

회절광을 이용한 기상계측용 표면거칠기의 측정시스템 (Measuring System of Surface Roughness for On-The-Machine using Diffraction Light)

  • 김성훈;이기용;강명창;김정석;김남경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.803-807
    • /
    • 2000
  • This paper deals wi th the establishment of the method of non-contact surface roughness measurement by developed system. One of the most Important factor of determinating quality of a produced manufacture is surface roughness The tendency of manufacturing method is changing from small amount manufactures / high-volume production to large amount manufactures / low volume production, and the study of reducing time for surface roughness measurement has been actively investigated The non-contact surface roughness method by using laser which is different from contact method has been only used to the polished surface, so new surface roughness measurement method was adopted by virtue of Fraunhofer diffraction in the periodic surface for on-the-machine. in this paper, we establish the method of non-contact surface roughness measurement which can reduce measuring time in the periodic surface

  • PDF

두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가 (Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness)

  • 유동식;문병연
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2157-2163
    • /
    • 2009
  • 소프트 콘택트렌즈의 산소투과성은 눈의 생리적 반응을 고려할 때 각막의 건강 상태를 결정하는 주요 파라미터이다. 이 연구의 목적은 폴라로그래피 방법을 이용하여 두께 기준에 따른 소프트 콘택트렌즈의 산소투과성을 평가하는데 있다. 렌즈의 두께는 접촉식과 비접촉식 방법으로 측정하였고, 정확도와 신뢰도를 평가하기 위하여 Bland-Altman 분석을 하였다. 정확도는 비접촉식 방법으로 측정한 중심 두께 기준의 산소투과성에서 높은 반면, 신뢰도는 접촉식 방법으로 측정한 중심 두께 기준의 산소투과성에서 높았다. 이 결과는 소프트 콘택트렌즈의 두께 측정방법과 기준에 따라 산소투과성이 다르며, 소프트 콘택트렌즈의 두께 측정은 비접촉식 방법이 보다 더 합리적임을 보여준다. 따라서 콘택트렌즈 임상 실무자들은 산소 공급 능력에 대한 데이터를 해석하거나 인용할 경우, 방법론 사이의 기본적 차이를 고려하여야 한다.

A Non-Cirucular Contact Arc Model for Temper Rolling

  • Y.L. Liu;Lee, W.H.;Cho, K.J.
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.293-300
    • /
    • 1999
  • A mathematical model for the analysis of roll gap phenomena in strip temper rolling process is described. The mechanical peculiarities of temper rolling process, such as high friction value and non-circular contact arc, low reduction and non-negligible entry and exit elastic zones as well as central restricted deformation (preliminary displacement or sticking) zone etc., are all taken into account. The deformation of work rolls is calculated with the influence function method and arbitrary contact arc shape is permitted. The strip deformation is modeled by slab method and the entry and exit elastic deformation zones are included. The restricted deformation zone near the neutral point is also considered. The concept and the calculation method of limiting preliminary displacement are used to determine the length of the central restricted deformation zone. The comparison of the model results with the measured mill data is also made.

  • PDF

비접촉식 설면 습윤도 측정 기구의 개발 (Development of the non contact tongue moisture measuring device)

  • 김대복;박유경;김기왕
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

Non-uniform virtual material modeling on contact interface of assembly structure with bolted joints

  • Cao, Jianbin;Zhang, Zhousuo;Yang, Wenzhan;Guo, Yanfei
    • Structural Engineering and Mechanics
    • /
    • 제72권5호
    • /
    • pp.557-568
    • /
    • 2019
  • Accurate modeling of contact interface in bolted joints is crucial in predicting the dynamic behavior for bolted assemblies under external load. This paper presents a contact pressure distribution based non-uniform virtual material method to describe the joint interface of assembly structure, which is connected by sparsely distributed multi-bolts. Firstly, the contact pressure distribution of bolted joints is obtained by the nonlinear static analysis in the finite element software ANSYS. The contact surface around bolt hole is divided into several sub-layers, and contact pressure in each sub-layer is thought to be evenly. Then, considering multi-asperity contact at the micro perspective, the relationship between contact pressure and interfacial virtual material parameters for each sub-layer is established by using the fractal contact theory. Finally, an experimental platform for the dynamic characteristics testing of a beam lap structure with double-bolted joint is constructed to validate the efficiency of proposed method. It is found that the theoretical results are in good agreement with experimental results by impact response in both time- and frequency-domain, and the relative errors of the first four natural frequencies are less than 1%. Furthermore, the presented model is used to examine the effect of rough contact surface on dynamic characteristics of bolted joint.

Pulsed Nd ; YGA 레이저의 치수마취효과에 관한 연구 (A STUDY OF ANALGESIC EFFECT ON PULP INDUCED BY PULSED Nd : YAG LASER)

  • 김도형;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.301-312
    • /
    • 1997
  • The purpose of this study was to evaluate the analgesic effect on pulp induced by pulsed Nd : YAG laser according to the power density, irradiated time and the method of application (Non-contact vs contact) in vivo. Experiments were carried out on 90 volunteers who have sound 4 canines. Each canine was grouped by the intensity and the time of irradiation of pulsed Nd : YAG laser was measured. Mean EPT response(units) was measured at 5 min, 30 min, and 60 min after irradiation with various intensity(1.5-3W, 15-30Hz), irradiated time (1.5min, 3min), and application method (Non-contact and contact). The results were as follows: 1. 5 minutes after irradiation, the mean EPT response(units) was increased by 32 % in the non-contact method and by 35% in the contact method of application. Which showed significant difference in mean EPT response(units) compared to not-lased canine in each groups(P<0.05). 2. The mean EPT response(units) with irradiating condition according to the various laser intensity, and the irradiation time stastically did not show significant difference in each groups as time elapsed. 3. There was no significant difference between the non-contact and contact method in the mean EPT response(units). 4. The mean EPT response(units) returned to the baseline value within 30 miuntes. In regard to the above results, the analgesic effect on pulp induced by pulsed Nd : YAG laser resulted a slight increase of pulpal pain threshold, but it was not as high as to replace the role of drug analgesia as whole. This technique can be used for inducing pulpal analgesia as adjunct to other pain control methods and is needed to develop better analgesic effects.

  • PDF

자기 변형 패치를 이용한 비자성 배관의 비접촉 종진동 모달 테스팅 (Non-contact Longitudinal Modal Testing of a Non-ferromagnetic Pipe Using Magnetostrictive Patches)

  • 박찬일;한순우;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제18권3호
    • /
    • pp.293-298
    • /
    • 2008
  • Non-contact modal testing for longitudinal modes of a pipe is discussed in this work. The suggested method can generate and measure longitudinal vibrations without mechanical contact by using the coupling phenomenon between deformation and magnetic field, known as the magnetostrictive effect. This effect has been used to generate and measure ultrasonic waves, but seldom used to deal with audible vibrations. In this investigation, the validity of the developed method in a typical vibration frequency range is checked with an Inconel pipe being used in nuclear power plants.

A Novel Non-contact Heart Rate Estimation Algorithm and System with User Identification

  • Kim, Chan-Il;Kim, Hyung-Jin;Kim, Seon-Chil;Park, Hee-Jun;Lee, Jong-ha
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.395-402
    • /
    • 2016
  • In these days, the wearable devices have been developed for measuring biological data effectively. However, wearable devices have tissue allege and noise problem. Also, it is impossible for a remote center to identify the person whose data are measured by wearable devices, which could trigger a communication problem over treatment. To solve these problems, biometric measurement based on a non-contact method, such as face image sequencing is necessary. This makes it possible to measure biometric data without any operation and side effects. This system can monitor the biological signals of people in real time without allege and noise and simultaneously identify them. In this paper, we propose an authentication process while measuring biometric data, through a non-contact method.