• Title/Summary/Keyword: Non-invasive

Search Result 1,225, Processing Time 0.031 seconds

Invasive and non-invasive methods for estimating the optical properties of tissue at laser wavelengths (레이저 파장에서의 생체 침습적 및 비침습적 광학계수 측정 방법)

  • Yoon, Gil-Won
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.147-150
    • /
    • 1994
  • To predict light propagation in biological tissues irradiated by laser, the optical properties such as absorption and scattering coefficients are required. There have been various techniques for measuring these coefficients. One method requires tissue samples, often a slab of thin tissue, is invasive. On the other hand, non-invasive method usually measures back-scattered light from a subject with no physical intervent ions. Advantages and disvantages of using different methods are investigated. A careful attention should be made in order to select the best method for a given experimental condition since, even either for invasive or non-invasive method, accuracy is subject to governing models and sample preparations.

  • PDF

Validation of Non-invasive Method for Electrocardiogram Recording in Mouse using Lead II

  • Kim, Myung Jun;Lim, Ji Eun;Oh, Bermseok
    • Biomedical Science Letters
    • /
    • v.21 no.3
    • /
    • pp.135-143
    • /
    • 2015
  • Electrocardiogram measures the electric impulses generated by the heart during its cycle. Recently genome-wide association studies on electrocardiogram traits revealed many relevant genetic loci. Therefore, these findings need to be validated and investigated to determine the underlying mechanisms using mouse models. Invasive radiotelemetry has been widely used to record the electrocardiogram in mice because it has several advantages over non-invasive measurements. However, radiotelemetry is expensive and requires complicated surgery. On the other hand, a non-invasive method using 3 electrodes (one for earth) for lead II is easy to establish and allows for rapid measurement. In this study, eleven mice were measured with this non-invasive method and no statistical difference among them was found in any ECG measurements. In addition, repeat measurement in the same mouse was performed in 9 sets of experiment and the results indicated that non-invasive method was reliable for reproducibility. Further it was shown that measurements for 1, 5, 10, and 15 minutes were not different so that a short recording such as 5 minutes was enough to estimate the ECG values including heart rate. Further this method was validated by measuring the ECG of Balb/c and FVB that were previously shown to differ in ECG values by radiotelemetry. Significant differences were found in heart rate, PR interval and corrected QT interval between these mouse strains. This study partially proved that non-invasive method also could provide the accuracy and reproducibility. Based on these results, the non-invasive ECG recordings of lead II is recommended as a useful method for quick test in mouse model.

Embryo sexing methods in bovine and its application in animal breed

  • Bora, Shelema Kelbessa
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.37 no.2
    • /
    • pp.80-86
    • /
    • 2022
  • The ability to determine the sex of bovine embryos before the transfer is advantageous in livestock management, especially in dairy production, where female calves are preferred in milk industry. The milk production of female and male cattle benefits both the dairy and beef industries. Pre-implantation sexing of embryos also helps with embryo transfer success. There are two approaches for sexing bovine embryos in farm animals: invasive and non-invasive. A non-invasive method of embryo sexing retains the embryo's autonomy and, as a result, is less likely to impair the embryo's ability to move and implant successfully. There are lists of non-invasive embryo sexing such as; Detection of H-Y antigens, X-linked enzymes, and sexing based on embryo cleavage and development. Since it protects the embryo's autonomy, the non-invasive procedure is considered to be the safest. Invasive methods affect an embryo's integrity and are likely to damage the embryo's chances of successful transformation. There are different types of invasive methods such as polymerase chain reaction, detection of male chromatin Y chromosome-specific DNA probes, Loop-mediated isothermal amplification (LAMP), cytological karyotyping, and immunofluorescence (FISH). The PCR approach is highly sensitive, precise, and effective as compared to invasive methods of farm animal embryonic sexing. Invasive procedures, such as cytological karyotyping, have high accuracy but are impractical in the field due to embryonic effectiveness concerns. This technology can be applicable especially in the dairy and beef industry by producing female and male animals respectively. Enhancing selection accuracy and decreasing the multiple ovulation embryo transfer costs.

An Implementation of Non-invasive Blood Pressure System Using Variable Characteristic Ratio (모듈방식의 가정용 혈압 측정 시스템 구현)

  • 이종수;노영아;이상용;박종억;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.7
    • /
    • pp.1263-1271
    • /
    • 2001
  • There are two methods in blood pressure measurement ; Invasive methode and Non-invasive method. The Invasive methode can get the 띠cod pressure measurement but, patient feel uncomfortable. So Non-invasive methode used generally. The Oscillometric method is typical Non-Invasive method. This method is commonly used to measure BP in electric sphygmomanometer and has various algorithm. In this paper it is described about a algorithm, it controls, determinates the cuff pressure, and fillers the measured BP data. This system can interface with PC(personal computer) by RS-232 and save the measured data in PC. This system deflates the cuff pressure by Solenoid valve. The main algorithm are oscillometric and maximum amplitude algorithm(MAA). MAA has various measured oscillation, it depends on patient's age, height, weight and arm circumference size. In this paper proposed system can measure Systolic BP, Diastolic BP, and Mean BP using Interpolation, Auto Reinflation algorithm.

  • PDF

Trends in Non-invasive Continuous Glucose Monitoring Technology (비침습 연속혈당 모니터링 기술동향)

  • Kim, J.;Kim, B.K.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.5
    • /
    • pp.9-20
    • /
    • 2021
  • A technology to replace the traditional blood sampling method for glucose monitoring has been sought for a long time. It is now possible to measure the blood glucose change rate continuously for more than 24 hours using a minimally invasive method that does not involve blood collection. Furthermore, various technology development efforts are being made for innovative diabetes management through intermittent or continuous blood glucose monitoring in a non-invasive manner. In this paper, we present an overview of diabetes and the need for continuous blood glucose measurement techniques., and then introduce various non-invasive blood glucose measurement techniques currently being studied. In addition, through research and analysis of the recent commercialization development status of minimally invasive, non-invasive, and wearable continuous blood glucose measurement technologies, we examine global development trends of future technologies.

A Study on the Effectiveness of Skin Care Solution System using Non-Invasive Air Technology

  • Park, Do-Young;Yoon, Dong-Gon;Seo, Jung-Gil
    • Journal of Platform Technology
    • /
    • v.10 no.3
    • /
    • pp.3-10
    • /
    • 2022
  • The effectiveness of an innovative skin treatment system that delivers an anti-aging solution deep into the skin without invasiveness and pain using a non-invasive air technology was investigated. In addition, an effective change using a non-invasive technique for delivering a solution for skin improvement was confirmed. The equipment named Cellre Jet is an effective skin care and drug delivery equipment that instantly opens the skin epidermis by using a maximum output pressure of 6 bars and high-pressure purified oxygen of 75-90% purity to deliver various nano-sized vital substances deep into the skin, and it uses the method of precisely controlling the equipment through an 8-inch digital touch display to accurately dispense the prescribed dosage. In this study, changes in skin condition were analyzed using this equipment and nano ampoules on subjects with actual skin problems through a related comparison and effectiveness judgment program. Through this study, skin care and drug delivery are possible, which will contribute to verifying the effectiveness of this non-invasive drug delivery equipment in the future, and is expected to establish the systematic effect in observing and studying changes in the skin.

A Non-invasive Real-time Respiratory Organ Motion Tracking System for Image Guided Radio-Therapy (IGRT를 위한 비침습적인 호흡에 의한 장기 움직임 실시간 추적시스템)

  • Kim, Yoon-Jong;Yoon, Uei-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.676-683
    • /
    • 2007
  • A non-invasive respiratory gated radiotherapy system like those based on external anatomic motion gives better comfortableness to patients than invasive system on treatment. However, higher correlation between the external and internal anatomic motion is required to increase the effectiveness of non-invasive respiratory gated radiotherapy. Both of invasive and non-invasive methods need to track the internal anatomy with the higher precision and rapid response. Especially, the non-invasive method has more difficulty to track the target position successively because of using only image processing. So we developed the system to track the motion for a non-invasive respiratory gated system to accurately find the dynamic position of internal structures such as the diaphragm and tumor. The respiratory organ motion tracking apparatus consists of an image capture board, a fluoroscopy system and a processing computer. After the image board grabs the motion of internal anatomy through the fluoroscopy system, the computer acquires the organ motion tracking data by image processing without any additional physical markers. The patients breathe freely without any forced breath control and coaching, when this experiment was performed. The developed pattern-recognition software could extract the target motion signal in real-time from the acquired fluoroscopic images. The range of mean deviations between the real and acquired target positions was measured for some sample structures in an anatomical model phantom. The mean and max deviation between the real and acquired positions were less than 1mm and 2mm respectively with the standardized movement using a moving stage and an anatomical model phantom. Under the real human body, the mean and maximum distance of the peak to trough was measured 23.5mm and 55.1mm respectively for 13 patients' diaphragm motion. The acquired respiration profile showed that human expiration period was longer than the inspiration period. The above results could be applied to respiratory-gated radiotherapy.

Diabetes is an Important Risk Factor for Metastasis in Non-Muscle-Invasive Bladder Cancer

  • Ozer, Kutan;Horsanali, Mustafa Ozan;Gorgel, Sacit Nuri;Ozbek, Emin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.105-108
    • /
    • 2016
  • Background: Epidemiological evidence indicates that individuals with diabetes mellitus (DM) may have a modestly increased risk of bladder cancer. In the present study, we aimed to show any association between DM and risk of metastasis in patients with non-muscle-invasive bladder cancer (NMIBC). Materials and Methods: We retrospectively analyzed 698 patients between January 2007 and December 2014 who were diagnosed with and underwent transurethral resection of bladder tumors (TUR-BT). Comparisons of means was conducted by independent samples t test, and relations between categorical variables were investigated by non-parametric chi-square test. A p value of 0.05 was accepted as statistically significant in comparisons. Results: We analyzed 418 patients with non muscle invasive bladder cancer. 123 of whom were diabetic and 295 non-diabetic. In diabetic patients, 13 were N1 stage and 11 M1 stage. When compared with non diabetic patients that was statistically significant (p<0.001). TNM stages were more advanced in diabetic patients (p<0.001), but concurrent CIS (p=0.1) and squamous metaplasia did not significantly differ between diabetic and non-diabetic cases (p=1). Conclusions: Diabetic patients with non-muscle-invasive bladder cancer may suffer metastases earlier than expected although they are non invasive. Therefore such patients must be followed-up carefully and early cystectomy decision may be necessary. Further prospective studies with more patients are needed to confirm these findings.

New Methods of Vagus Nerve Stimulation : Therapeutic Effects of Non-Invasive Vagus Nerve Stimulation by TENS Application (미주신경 자극을 위한 새로운 방법 : 비침습적 TENS 적용에 대한 미주신경 자극의 치료적 효과)

  • Kwon, Haeyeon;Moon, Hyunju
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.4
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the therapeutic effect of non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation application on the autonomic nervous system of human body. Methods: Participants were seventeen healthy adults. Standard deviation of all normal N-N intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF) were compared in pre and post Mean values after intervention. Data were analyzed in Wilcoxon's signed-ranks test. Results: The results of this study is that sistolic blood pressure and pulse rate decreased mean value after non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation. High frequency, low frequency, SDNN, RMSSD increased mean value in heart rate variability after intervention. But that is not significant except for SDNN. Conclusion: Non-invasive vagus stimulation by transcutaneous electrical nerve stimulation effect on parasympathetic nerve stimulation, and then it might be effective method for autonomic nerve balance control.

Non-invasive different modalities of treatment for temporomandibular disorders: review of literature

  • Abouelhuda, Amira Mokhtar;khalifa, Ahmad Khalifa;Kim, Young-Kyun;Hegazy, Salah Abdelftah
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.2
    • /
    • pp.43-51
    • /
    • 2018
  • Temporomandibular disorders (TMDs) are diseases that affect the temporomandibular joint and supporting structures. The goal of treatment for TMDs is elimination or reduction of pain and return to normal temporomandibular joint function. Initial treatment for TMDs is non-invasive and conservative, not surgical. Oral and maxillofacial surgeons should fully understand and actively care about non-invasive treatments for TMDs. The purpose of this study is to review the validity and outcomes of non-invasive and surgical treatment modalities for TMDs.