• Title/Summary/Keyword: Non-stick

Search Result 73, Processing Time 0.048 seconds

Design of Non-stick Micromanipulation for Handling of Micro particle (초소형 부품 조작을 위한 Non-stick 마이크로 매니퓰레이션 시스템의 설계)

  • Ihn, Y.S.;Kim, Y.C.;Choi, H.R.;Lee, S.M.;Koo, J.C.
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.3
    • /
    • pp.225-232
    • /
    • 2009
  • In the high precision robot systems, the most popular tasks may be handling of micro-scale objects on a surface such as a micromanipulation robot system. In handling of micro-scale objects, the stiction effect becomes a fundamental issue since the micro-contact mechanics dominates the micromanipulation robot system. In the paper, a theoretical non-stick condition derived from the micro-contact mechanics is carried out for the propose of micro-scale object manipulation. To verify the non-stick condition, a micro-manipulation robot system equipped with a high precision stage system and a microscope system is developed. Experimental results show that the proposed non-stick condition guarantees successful micro-scale object manipulation.

  • PDF

Tribological Properties of Hybrid Friction Materials: Combining Low-steel and Non-steel Friction Materials (금속계와 유기계 마찰재의 분포에 따른 하이브리드 마찰재의 마찰 특성)

  • Kim, JinWoo;Jang, Ho
    • Tribology and Lubricants
    • /
    • v.28 no.3
    • /
    • pp.117-123
    • /
    • 2012
  • Tribological properties of hybrid type friction materials were studied. Hybrid friction materials were produced by combining non-steel(NS) and low-steel(LS) type friction materials. The emphasis of the investigation was given to possible synergistic effects from the two different friction materials, in terms of friction stability at high temperatures and the amplitude of friction oscillation, also known as stick-slip at low sliding speeds. The high temperature friction test results showed that the friction effectiveness of the hybrid friction material was well sustained compared to LS and NS friction materials. Wear resistance of the hybrid type was similar to LS friction materials. Examination of the rubbing surfaces after tests revealed that the friction characteristics of the hybrid friction material were attributed to the wear debris produced from low-steel friction materials, which were migrated to the surface of the non-steel friction material, forming new contact plateaus. The stick-slip amplitude and its frequency were pronounced when non-steel friction material was tested, while hybrid and low-steel types showed relatively small stick-slip amplitudes. These results suggest possible improvement of tribological properties by designing a hybrid composite of low-steel and non-steel friction materials.

FIGURE-8 KNOT ON THE CUBIC LATTICE

  • Oh, Seung-Sang
    • Honam Mathematical Journal
    • /
    • v.30 no.1
    • /
    • pp.165-170
    • /
    • 2008
  • We will examine the stick number of knots on the cubic lattice which is called the lattice stick number. The lattice stick numbers of knots $3_1$ and $4_1$ are known as 12 and 14, respectively. In this paper, we will show that only $3_1$ and $4_1$ have representations of irreducible non-trivial polygons, both numbers of whose sticks parallel to the y-axis and the z-axis are exactly four.

Numerical Study of Detonation for AN based non-ideal explosives via an Eulerian multi-material method (Ammonium Nitrate 계열의 폭발물의 폭굉에 관한 연구)

  • Kim, Kihong;Lee, Jinwook;Yoh, Jaiick
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.89-91
    • /
    • 2012
  • The numerical simulation for detonation failure of ammonium nitrate (AN) based non-ideal explosives is carried out with an accurate and state-of-the-art Eulerian method. Detonation failure is readily observed in the rate stick experiments utilizing the AN mixture explosives and the inert confinements of varying thicknesses. The composition of non-ideal explosives and thickness of the confinements influence the characteristics of detonation failure. Calculated results are compared against the experimental data of both unconfined and confined rate stick problems and provide a reliable guideline to establish a fine-tuned chemical kinetic model for detonation failure.

  • PDF

Study on the reduction of stick-slip noise in acrylonitrile butadiene styrene-based plastics using non-polar additives to reduce friction (마찰 저감을 위한 비극성 첨가제에 따른 acrylonitrile butadiene styrene계 플라스틱의 stick-slip 이음 저감 연구)

  • Sangjun Yeo;Yewon Jeong;Sunguk Choi;Hyojun Kim;Geonwook Park;Minyoung Shon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.49-59
    • /
    • 2024
  • Recently, the electric vehicle market is gradually growing due to strengthened environmental regulations and high oil prices. also, in internal combustion engine vehicles, the sensitivity of Buzz, Squeak, Rattle (BSR) noise is increasing as engine Noise, Vibration, and Harshness (NVH)-related noise is reduced and technology for shielding noise coming from outside is developed. In this study, the stick-slip noise that occurs in Panoramic Curved Display (PCD) of automobile was analyzed for the correlation between the surface energy of polymer plastic and the polar component. For polar polymer materials, Acrylonitrile Butadiene Styrene (ABS) and PolyCarbonate-Acrylonitrile Butadiene Styrene (PC-ABS), compound materials were fabricated and evaluated. As a result, when the polar component of the polymer plastic was 3.86 mN/m or higher, stick-slip motion occurred, and as the absolute transition slope increased in the friction behavior over time, the possibility of stick-slip noise increased and the value of the friction coefficient The greater the difference, the greater the strength of the stick-slip noise.

Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF

Fiber Dimensions and Chemical Properties of Various Nonwood Materials and Their Suitability for Paper Production

  • lahan M. Sarwar;Mun Sung Phil;Rashid Mamunur
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.5 s.108
    • /
    • pp.29-35
    • /
    • 2004
  • Fiber dimensions, their derived values and chemical properties of cotton stalks (Gosypium hirsutum L), jute stick (Corchorus capsularis) and dhancha (Sesbania aculeate) have been examined to assess their suitability for paper production. Cotton stalks have a good derived values especially slender ratio, which is comparable to hardwood. The flexibility coefficient of these three non wood plants is better than hardwood. Anatomical analysis shows higher percentage of fibers and vessels than in general non wood plants. Lignin, $\alpha$-cellulose and pentosan contents in these three nonwood plants are within the range of hardwood. Neutral sugar analysis of cotton stalks, jute stick and dhancha shows that the glucose in the major sugar followed by xylose and mannose. The arabinose and galactose are present in minor amount. Alkaline nitrobenzene oxidation of cotton stalks, jute stick and dhancha wood meal exhibits that these nonwood plant lignins mainly consist of syringyl (S) and guaiacyl (V) units. The S/V ratios are 1.6, 1.2 and 2.1 for cotton stalks, jute stick and dhancha, respectively.

Experimental Interpretation of Heat Transmits Pattern on Warm Needling (온침의 열전달 특성에 대한 실험적 해석)

  • Yang, Seung-Bum;Park, Soon-Jae;Lee, Jae-Gun;Jung, Ji-Chul;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.34 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • Objectives : Many researches have studied warm needling technique to standardize its treatment by temperature measurement and material differences in the effectiveness. The purpose of this study is to compare the temperature changes of the acupuncture needle shaft during the combustion process of the moxa stick to determine the heat transfer pattern of the warn needling. Methods : A moxa stick($7{\times}8mm$) was connected to one side of the needle shaft using a stainless steel needle(ø 0.3 mm, ø 0.5 mm, ø 0.8 mm, shaft length 40 mm) with the needle handle removed. During the warm needling, temperature changes of the needle shaft were observed with an infrared camera(Flir E30) and an infrared thermometer(TESTO 845). Results : In the normal condition, heat transmit of needle shaft increased at spots 10 mm and 25 mm below the moxa stick. The amount of heat transmit increased with the diameter of needle shaft. However, when the heat shield was installed to exclude radiant heat from the moxa stick, heat transfer was less at 10 mm below the moxa stick and no temperature change was observed at 25 mm below the moxa stick. Heat transfer by warm needling does not reach the end of needle shaft even in ø 0.8 mm needle. Conclusions : It is suggested that the radiant heat of moxa stick results in the heat transmit of acupuncture needle shaft. Thus, radiant heat transmit must be considered as one of the heat transfer characteristics of the warm needling.

A Study on the Characteristics of an Amplitude Proportional Friction Damper (변위비례식 마찰댐퍼의 특성에 관한 연구)

  • 박동훈;최명진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.717-720
    • /
    • 2002
  • An Amplitude Proportional Friction Damper (APFD) system is considered in order to improve the stick-slip characteristics of Coulomb friction damper. The frictional force is proportional to the amplitude in APFD system and the system is non-linear as is Coulomb damper system. The free vibration analysis on an 1-DOF system has conducted to demonstrate the characteristics of the APFD system and the results show that the APFD system has similar damping characteristics to the viscous damper system. It is concluded that the APFD system may become a cost effective substitution for the viscous damper and it also has certain advantages over Coulomb damper system since the APFD system can be designed to work with no stick-slip.

  • PDF

Knowledge, Compliance and Levels of Risk Factor Recognition for Needlestick Injuries in Student Nurses (간호대학생의 주사침 자상에 대한 지식, 이행 및 위험인식)

  • Park Sun-Nam;Lee Eun-Young;Kim Kyung-Mi;Han Suk-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.12 no.3
    • /
    • pp.337-346
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate the levels in student nurse of knowledge, compliance and risk factor recognition for needlestick injuries. Method: Nine hundred and thirty eight(938) student nurse from 3 universities and 3 junior colleges participated in this study. Completed questionnaires were collected between October and November 2004. They were analyzed by using the descriptive statistics and $x^2$-test, t-test with the SAS program, Results: There were no significant differences in the general characteristics of participants between the two groups-Needlestick Injury(NSI) group and non-Needle stick Injury(non-NSI) group. The scores for knowledge levels of treatment after needle stick injuries and the risk factor recognition level were significantly higher in the NSI group. The scores for performance level as to handling and using needles after needlestick injuries were significantly higher in the non-NSI group. Conclusion: It is necessary to develop a preventive program to decrease the needlestick injury rate among student nurse.

  • PDF