• Title/Summary/Keyword: Noninvasive Method

Search Result 267, Processing Time 0.023 seconds

NMR Microimaging for Noninvasive Investigation of Polymers (고분자의 비파괴 연구를 위한 핵자기 공명 현미영상법)

  • Lee, D.H.;Ko, R.K.;Moon, C.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.253-256
    • /
    • 1995
  • Polymers have been one of the emerging biomedical materials in the area of biomedical research which are applicable to the human body. For human applications, noninvasive characterization of the biomedical polymers has been one of the important topics, and is valuable information. Among others, the swelling rate is one of the important measurements needed for the hydrophilic polymers. NMR imaging has been a suitable method for the noninvasive study of such a material since it is sensitive to many physical and biochemical changes of the specimens. In addition, NMR techniques possess many useful intrinsic properties such as the relaxation and diffusion effects. The present study has provided a noble and noninvasive method of measuring the process of swelling as well as volumetric changes occurred in polymers and drug delivery processes in a drug delivery system (DDS) together with changes of released drug. This gives information, relating with both water ingress process, volumetric changes of polymer specimens and the visualization of sequential drug delivery process. Also, this study provides more reliable method to ascertain the time dependent swelling process compared to the conventional method. The important aspects is that the proposed method is truly noninvasive and is able to ascertain time dependent processes.

  • PDF

Artifical Neural Network for In-Vitro Thrombosis Detection of Mechanical Valve

  • Lee, Hyuk-Soo;Lee, Sang-Hoon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.762-766
    • /
    • 1998
  • Mechanical valve is one of the most widely used implantable artificial organs, Since its failure (mechanical failures and thrombosis to name two representative example) means the death of patient, its reliability is very important and early noninvasive detection is essential requirement . This paper will explain the method to detect the thrombosis formation by spectral analysis and neural network. In order quantitatively to distinguish peak of a normal valve from that of a thrombotic valve, a 3 layer backpropagation neural network, which contains 7,000 input nodes, 20 hidden layer and 1output , was employed. The trained neural network can distinguish normal and thrombotic valve with a probability that is higher than 90% . In conclusion, the acoustical spectrum analysis coupled with a neural network algorithm lent itself to the noninvasive monitoring of implanted mechanical valves. This method will be applied to be applied to the performance evaluation of other implantable rtificial organs.

  • PDF

Application of digital polymerase chain reaction technology for noninvasive prenatal test

  • Lee, Seung Yong;Hwang, Seung Yong
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.72-78
    • /
    • 2015
  • Recently, noninvasive prenatal test (NIPT) has been adopted as a primary screening tool for fetal chromosomal aneuploidy. The principle of NIPT lies in isolating the fetal fraction of cell-free DNA in maternal plasma and analyzing it with bioinformatic tools to measure the amount of gene from the target chromosome, such as chromosomes 21, 18, and 13. NIPT will contribute to decreasing the need for unnecessary invasive procedures, including amniocentesis and chorionic villi sampling, for confirming fetal aneuploidy because of its higher positive predictive value than that of the conventional prenatal screening method. However, its greater cost than that of the current antenatal screening protocol may be an obstacle to the adoption of this innovative technique in clinical practice. Digital polymerase chain reaction (dPCR) is a novel approach for detecting and quantifying nucleic acid. dPCR provides real-time diagnostic advantages with higher sensitivity, accuracy, and absolute quantification than conventional quantitative PCR. Since the groundbreaking discovery that fetal cell-free nucleic acid exists in maternal plasma was reported, dPCR has been used for the quantification of fetal DNA and for screening for fetal aneuploidy. It has been suggested that dPCR will decrease the cost by targeting specific sequences in the target chromosome, and dPCR-based noninvasive testing will facilitate progress toward the implementation of a noninvasive approach for screening for trisomy 21, 18, and 13. In this review, we highlight the principle of dPCR and discuss its future implications in clinical practice.

Use of Genetic Techniques to Analyze Wintering Population of Geese in Korea with Noninvasive Feces Samples (비침습적 분변 샘플을 이용한 우리나라 월동 기러기류의 유전분석)

  • Kim, Min-Kyung;Won, Yong-Jin;Lee, Sang-Don
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.3
    • /
    • pp.264-269
    • /
    • 2008
  • This study was intended to test the feasibility of genetic analysis of wintering population of geese using their feces samples. This noninvasive approach is quite significant and effective because we do not need to capture or harm geese to obtain the samples. We collected the feces from two different populations of wintering geese in Korea in 2007. Finally thirty two feces were analyzed through a molecular genetic method. As a result, 14 haplotypes were identified and classified into two groups, white-fronted geese (Anser albifrons) and bean geese (Anser fabalis). We established the method to make molecular genetic experiment more efficient using the feces. This study has a significance as the first genetic result on wintering population of geese in Korea using noninvasive sampling method.

Whole genome sequencing based noninvasive prenatal test

  • Cho, Eun-Hae
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.61-65
    • /
    • 2015
  • Whole genome sequencing (WGS)-based noninvasive prenatal test (NIPT) is the first method applied in the clinical setting out of various NIPT techniques. Several companies, such as Sequenom, BGI, and Illumina offer WGS-based NIPT, each with different technical and bioinformatic approaches. Sequenom, BGI, and Illumina utilize z-, t-, and L-scores, as well as normalized chromosome values, respectively, for trisomy detection. Their outstanding performance has been demonstrated in clinical studies of more than 100,000 pregnancies. The sensitivity and specificity for detection of trisomies 13, 18, and 21 were above 98%, as reported by all three companies. Unlike other techniques, WGS-based NIPT can detect other trisomies as well as clinically significant segmental duplications/deletions within a chromosome, which could expand the scope of NIPT. Incorrect results could be due to low fetal fraction, fetoplacental mosaicism, confined placental mosaicism or maternal copy number variation (CNV). Among those, maternal CNV is a significant contributor of false positive results and therefore genome wide scanning plays an important role in preventing the occurrence of false positives. In this article, the bioinformatic techniques and clinical performance of three major companies are comprehensively reviewed.

High-flow nasal cannula oxygen therapy in children: a clinical review

  • Kwon, Ji-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.1
    • /
    • pp.3-7
    • /
    • 2020
  • High-flow nasal cannula (HFNC) is a relatively safe and effective noninvasive ventilation method that was recently accepted as a treatment option for acute respiratory support before endotracheal intubation or invasive ventilation. The action mechanism of HFNC includes a decrease in nasopharyngeal resistance, washout of dead space, reduction in inflow of ambient air, and an increase in airway pressure. In preterm infants, HFNC can be used to prevent reintubation and initial noninvasive respiratory support after birth. In children, flow level adjustments are crucial considering their maximal efficacy and complications. Randomized controlled studies suggest that HFNC can be used in cases of moderate to severe bronchiolitis upon initial low-flow oxygen failure. HFNC can also reduce intubation and mechanical ventilation in children with respiratory failure. Several observational studies have shown that HFNC can be beneficial in acute asthma and other respiratory distress. Multicenter randomized studies are warranted to determine the feasibility and adherence of HFNC and continuous positive airway pressure in pediatric intensive care units. The development of clinical guidelines for HFNC, including flow settings, indications, and contraindications, device management, efficacy identification, and safety issues are needed, particularly in children.

Update of minimally invasive surfactant therapy

  • Shim, Gyu-Hong
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.9
    • /
    • pp.273-281
    • /
    • 2017
  • To date, preterm infants with respiratory distress syndrome (RDS) after birth have been managed with a combination of endotracheal intubation, surfactant instillation, and mechanical ventilation. It is now recognized that noninvasive ventilation (NIV) such as nasal continuous positive airway pressure (CPAP) in preterm infants is a reasonable alternative to elective intubation after birth. Recently, a meta-analysis of large controlled trials comparing conventional methods and nasal CPAP suggested that CPAP decreased the risk of the combined outcome of bronchopulmonary dysplasia or death. Since then, the use of NIV as primary therapy for preterm infants has increased, but when and how to give exogenous surfactant remains unclear. Overcoming this problem, minimally invasive surfactant therapy (MIST) allows spontaneously breathing neonates to remain on CPAP in the first week after birth. MIST has included administration of exogenous surfactant by intrapharyngeal instillation, nebulization, a laryngeal mask, and a thin catheter. In recent clinical trials, surfactant delivery via a thin catheter was found to reduce the need for subsequent endotracheal intubation and mechanical ventilation, and improves short-term respiratory outcomes. There is also growing evidence for MIST as an alternative to the INSURE (intubation-surfactant-extubation) procedure in spontaneously breathing preterm infants with RDS. In conclusion, MIST is gentle, safe, feasible, and effective in preterm infants, and is widely used for surfactant administration with noninvasive respiratory support by neonatologists. However, further studies are needed to resolve uncertainties in the MIST method, including infant selection, optimal surfactant dosage and administration method, and need for sedation.

Effects of noninvasive electrical stimulation combined trunk stabilization exercise on balance and fall risk in stroke patients (비침습적 전기자극과 결합한 몸통 안정화 운동이 뇌졸중 환자의 균형 및 낙상 효능감에 미치는 영향)

  • Shuang-yan, Liu;Dae-jung, Yang;Jong-hyok, Yun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.61-68
    • /
    • 2022
  • Background: This study aimed to investigate the effects of noninvasive electrical stimulation combined with trunk stabilization exercise on balance and fall risk in patients with stroke. Methods: Twenty-two patients with stroke were enrolled in the study and randomly divided into experimental and control groups, each with 11 patients. noninvasive electrical stimulation combined with trunk stabilization training was applied to the experimental group, and sham noninvasive electrical stimulation combined with trunk stabilization training, to the control group. Both groups were treated for 6 weeks, five times a week for 30 min each time; the balance and fall risk of patients with stroke were measured before and after treatment, and the changes in the two groups were compared and analyzed. Results: The experimental group's left and right weight-bearing indices (affect and non-affect sides) and the front and rear weight-bearing indices, were significantly improved (p<.05, p<.001). when the changes in balance ability between groups were compared before and after treatment. The total fall efficacy score in the experimental group was substantially lower than that in the control group when the changes in fall efficacy score were compared between groups following treatment (p<.001). Conclusion: The improvement in balance and fall risk in patients with stroke can be attributed to using noninvasive electrical stimulation in combination with trunk stabilization training. This clinically helpful treatment method for patients with stroke warrants further promotion and implementation in the clinic.

A Basic Study on the Estimation of Noninvasive Temperature Distribution in Carcinoma Cell for the Hyperthermia (가온요법을 위한 암조직 세포의 무침습 온도분포 추정에 관한 기초연구)

  • Lee, Myeon-Seop;Kim, Nak-Hwan;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.11-20
    • /
    • 1986
  • In the clincal application of Hyperthermia, tissue temperature measurements are made at only a few selecte4 locations because of patient tolerance and practical clinical limitation. Since it is necessary to know the complete carcinoma cell temperature field in order to treat effectively, The difficulty of making such estimates from only a few point compounded because of the lack of knowledge of the carcinomoma cell blood perfusion characteristics. To solve the temperature on carcinoma cell, A noninvasive method (the finite element method) is used. The simulation results show that the finite element method is promising for estimating the complete corcinoma cell temerature distribution, if some knowledge of the blood perfusion pattern is available.

  • PDF

Frequency domain analysis of the urophonography for LUTS diagnosis (하부요로 폐색 진단을 위한 요류음 주파수 분석)

  • Jeong, Do-Un;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.202-210
    • /
    • 2007
  • The aim of this study is to acquire useful information of lower urinary tract symptom (LUTS) diagnosis through urophonography signal as a noninvasive method. The hardware and software which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and urophonography signal during urination. The PSD (power spectrum density) and the log-log plot gradient analysis were accomplished in frequency domain. For evaluation of the system and analysis method, a model system for the lower urinary system of men was used. From the evaluation of the model system, the PDS and the log-log plot gradient were dependent on the occlusion degree significantly. In a pilot study on normal and abnormal male subjects, the PSD and the log-log plot gradient were highly correlated with the artificial urethral obstruction.