• Title/Summary/Keyword: Nuclear I%26C

Search Result 44, Processing Time 0.03 seconds

Effects of temperature and solution composition on evaporation of iodine as a part of estimating volatility of iodine under gamma irradiation

  • Yeon, Jei-Won;Jung, Sang-Hyuk
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1689-1695
    • /
    • 2017
  • As a part of evaluating the volatility of iodide ions subjected to gamma irradiation, $I_2$ evaporation experiments were performed with $I_2$ and $I^-$ mixed solutions in the temperature range $26-80^{\circ}C$ in an open, well-ventilated space. The evaporation of $I_2$ was observed to follow primarily first order kinetics, depending on the $I_2$ concentration. The evaporation rate constant increased rapidly with increase in temperature. The presence of $I^-$ slightly reduced the evaporation rate of $I_2$ by forming relatively stable $I_3^-$. The effect of $Cl^-$ at <1.0 wt% on $I_2$ evaporation was insignificant. The evaporation rate constants of $I_2$ were $1.3{\times}10^{-3}min^{-1}\;cm^{-2}$, $2.4{\times}10^{-2}min^{-1}\;cm^{-2}$, and $8.6{\times}10^{-2}min^{-1}\;cm^{-2}$, at $26^{\circ}C$, $50^{\circ}C$, and $80^{\circ}C$, respectively.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Anti-inflammatory effects of Chrysanthemum boreale flower (산국 꽃의 항염 활성 연구)

  • You, Ki-Sun;Bang, Chan-Sung;Lee, Kyung-Jin;Ham, In-Hye;Choi, Ho-Young
    • The Korea Journal of Herbology
    • /
    • v.26 no.4
    • /
    • pp.31-37
    • /
    • 2011
  • Objectives : Chrysanthemum boreale flower is widely distributed in Korea, Japan, China, and Eastern countries. C. boreale flower is also one of the herbs used for the treatment of various inflammatory disease in Korean Medicine. So, this research was designed to study anti-inflammatory effect of C. boreale flower and its mechanism. Methods : We investigated nitro oxide (NO) and prostaglandin $E_2$ ($PGE_2$) production by ELISA. And expressions of inducible nitric oxide synthase (iNOS), Cyclooxygenase-2 (COX-2) and nuclear factor-${\kappa}B$ P50/65 (NF-${\kappa}B$ P50, NF-${\kappa}B$ P65) were measured in RAW 264.7 murine macrophage cells induced by LPS. Results : MeOH ex., EtOAc fr., $CHCl_3$ fr. and Water fr. of C. boreale flower showed anti-inflammatory effect through inhibition of NO and PGE expression respectively. Among them, EtOAc fr. and $CHCl_3$ fr. inhibited production of NO and $PGE_2$ through inhibition of iNOS and COX-2 expression. And MeOH ex., EtOAc fr. and $CHCl_3$ fr. inhibited translocation of NF-${\kappa}B$ P65, NF-${\kappa}B$ P50 by inhibiting phosphrylation of $I{\kappa}B$. Conclusions : MeOH ex. EtOAc fr, $CHCl_3$ fr., and Water fr. of the C. boreale flower have anti-inflammatory activity.

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

A Study on the Reactivity Effect due to Expansion of Diagrid and Pad (Diagram와 Pad의 팽창에 의한 반응도 효과에 대한 연구)

  • Young In Kim;Keun Bae Oh;Kun Jong Yoo;Mann Cho
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.70-79
    • /
    • 1984
  • With the help of the nuclear computational system for a large LMFBR (KAERI-26 group cross section library/1DX/2DB), the reactivity coefficients for the diagrid expansion and the pad expansion at the beginning of cycle of the equilibrium core of SUPER-PHENIX I are calculated and reviewed. the core is described using R-Z geometry model, and a two-dimensional multigroup diffusion theory is used. For reference cases, reactivity calculations for radial and axial uniform expansion are performed, and also calculated are reactivity variations due to changes in material density and core volume. The reactivity coefficient for the diagrid expansion is calculated to be -0.553pcm/mil. The temperature coefficient corresponding to the above value is -1.0766pcm/$^{\circ}C$ and is well in accord with the French datum of -1.09pcm/$^{\circ}C$ within 1.2% difference. With the use of 4he calculational method for the diagrid expansion effect, reactivity calculations for the pad expansion bringing about nonuniform expansion are performed, which show that the calculational method is very useful in the analysis of the pad expansion effect. The reactivity coefficients for the pad expansion are calculated to be -0.2743 pcm/mil and -0.2786pcm1mi1 for the averaged expansion model and for the integrated pancake model, respectively. Under the assumption of the free expanding core the temperature reactivity coefficients for each model are obtained to be -0.5766pcm/$^{\circ}C$ and -0.5858pcm/$^{\circ}C$, both of which agree with the French datum of -0.574pcm/$^{\circ}C$ within 2% difference.

  • PDF

Developmental Characteristics of Cloned Embryos Reconstructed with Induced Pluripotent Stem Cells in Pigs (돼지 유도만능줄기세포 유래 복제란의 특성 분석)

  • Kwon, Dae-Jin;Oh, Jae-Don;Park, Mi-Ryung;Hwang, In-Sul;Park, Eung Woo;Hwang, Seongsoo
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.34 no.3
    • /
    • pp.232-239
    • /
    • 2019
  • In general, cloned pigs have been produced using the somatic cell nuclear transfer (SCNT) technique with various types of somatic cells; however, the SCNT technique has disadvantages not only in its low efficiency but also in the development of abnormal clones. This study aimed to compare early embryonic development and quality of SCNT embryos with those of induced pluripotent stem cells (iPSCs) NT embryos (iPSC-NTs). Ear fibroblast cells were used as donor cells and iPSCs were generated from these cells by lentiviral transduction with human six factors (Oct4, Sox2, c-Myc, Nanog, Klf4 and Lin28). Blastocyst formation rate in iPSC-NT (23/258, 8.9%) was significantly lower than that in SCNT (46/175, 26.3%; p < 0.05). Total cell number in blastocysts was similar between two groups, but blastocysts in iPSC-NT had a lower number of apoptotic cells than in SCNT (2.0 ± 0.6 vs. 9.8 ± 2.9, p < 0.05). Quantitative PCR data showed that apoptosis-related genes (bax, caspase-3, and caspase-9) were highly expressed in SCNT than iPSC-NT (p < 0.05). Although an early development rate was low in iPSC-NT, the quality of cloned embryos from porcine iPSC was higher than that of embryos from somatic cells. Therefore, porcine iPSCs could be used as a preferable cell source to create a clone or transgenic animals by using the NT technique.

Anti-tumor and Anti-inflammatory Effects of Ecklonia cava in CT26 Tumor-bearing BALB/cKorl Syngeneic Mice (CT26 고형암을 내포하는 BALB/cKorl Syngeneic 마우스에서 Ecklonia cava의 항암효과 및 항염증효과)

  • Yu Jeong Roh;Ji Eun Kim;You Jeong Jin;Ayun Seol;Hee Jin Song;Tae Ryeol Kim;Kyeong Seon Min;Eun Seo Park;Ki Ho Park;Dae Youn Hwang
    • Journal of Life Science
    • /
    • v.33 no.11
    • /
    • pp.887-896
    • /
    • 2023
  • The inflammatory response have been considered as one of important targets for cancer treatment because they play a key role during all steps of tumor development including initiation, promotion, malignant conversion and progression. To investigate the anti-inflammatory response during anti-tumor activity of an aqueous extracts of Ecklonia cava (AEC), alterations on the distribution of mast cells and the expression of inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2), nuclear factor (NF)-κB, inflammasome compositional protein and inflammatory cytokines were examined in CT26 colon tumor-bearing BALB/cKorl syngeneic mice after administrating AEC for five weeks. After treatment of AEC, total weight of tumor and necrotic region of tumor section were significantly decreased compared to vehicle treated group. The number of infiltered mast cells was higher in AEC treated group than vehicle treated group, while the expression levels of COX-2 and iNOS were decreased in AEC treated group. Also, similar decrease pattern were detected in the expression levels of NF-κB, NLR family pyrin domain containing 3 (NLRP3), apoptosis-associated speck-like protein containing a caspase recruitment domain (ASC) and caspase-1 (Cas-1) after AEC treatment although the decrease rate was varied. Furthermore, the mRNA expressions of three inflammatory cytokines including tumor necrosis factor-α (TNF-α), interleukin-1α (IL-1α) and interleukin-6 (IL-6) were remarkably decreased in AEC treated group compared to vehicle treated group. These results suggest that inhibition of inflammatory response may be tightly associated with anti-tumor activity of AEC in CT26 colon tumor-bearing BALB/cKorl syngeneic mice.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Low Cycle Fatigue Characteristics of Duplex Stainless Steel with Degradation under Pure Torsional Load (순수 비틀림 하중하에서 열화를 고려한 2상 스데인리스강의 저주기 피로특성)

  • Gwon, Jae-Do;Park, Jung-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1897-1904
    • /
    • 2002
  • Monotonic torsional and pure torsional low cycle fatigue(LCF) test with artificial degradation were performed on duplex stainless steel(CF8M). CF8M is used in pipes and valves in nuclear reactor coolant system. It was aged at 430$^{\circ}C$ for 3600hrs. Through the monotonic and LCF test, it is found that mechanical properties(i.e., yield strength, strain hardening exponent, strength coefficient etc.) increase and fatigue life(N$\sub$f/) decreases with degradation of material. The relationship between shear strain amplitude(${\gamma}$$\sub$a/)and N$\sub$f/ was proposed.

Fine Structure of Neurons and Synaptic Organization in Pallidum of the Cat (고양이 담창구 (Globus Pallidus)의 신경원과 연접기구에 대한 미세구조)

  • Park, W.B.;C.Y. Yun
    • The Korean Journal of Zoology
    • /
    • v.26 no.2
    • /
    • pp.107-123
    • /
    • 1983
  • The globus pallidus of normal cats were prepared for electron microscopic study following perfusion with a mixture of 1% paraformaldehyde and 1% glutaraldehyde solution. Neurons of two size categories were identified in 1 $\\mu$m araldite sections and their ultrastructural characteristics were studied in adjacent thin section. 1. Large neurons ($30 \\mum \\times 45 \\mum$ in diameter) had extensive areas of rough surfaced endoplasmic reticulm, abundant perinuclear Golgi complex, numerous mitochondria and lipofusin granule, and had a large spherical nucleus with shallow indentation of nuclear manbrane. Small neurons ($17 \\mum \\times 27 \\mum$ in diameter) had poorly rough surfaced endoplasmic reticulum, moderate number of mitochondria and randomly distributed Golgi complex. The nuclear envelope of this cell frequently showed multiple deep invagination. 2. Three types of axo-somatic synapses were identified on the basis of the size and shape of vesicle in the axon terminal and the symmetrical or asymmetrical thickening at the synaptic site. Type I synaptic terminal shows an even distribution of round and oval synaptic vesicles, and has a symmetrical synaptic thickening. Type II axon terminals reveal mostly round and pleomorphic vesicles and a few vesicles were localized near the presynaptic membrane in pale axoplasm and its synaptic thickening were symmetric. Type III axon terminals contain round vesicles, which were aggregated in the axoplasm, and has a asymmetrical synaptic thickening. 3. The majority of axo-somatic contact with the large and small neurons were type I, and type II and III synapes were rare.

  • PDF