• 제목/요약/키워드: On-current

검색결과 53,091건 처리시간 0.072초

전류 전처리의 경피 투과도에 미치는 효과 (Current Pretreatment of Skin and Its Effect on the Permeability)

  • 이정화;오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권2호
    • /
    • pp.81-87
    • /
    • 2005
  • We have prepared karaya gum patches containing ketoprofen and investigated the effect of short-time current pretreatment of skin on the permeability. Hairless mouse skin was treated with current before the patch was mounted on the skin. The effect of current density and current duration on the flux of ketoprofen was studied. The possibility of additive effect with penetration enhancer (PGML) was also investigated. Iontophoretic pretreatment of skin increased the passive flux up to 3 folds at 0.4 $mA/cm^2$ current density, when the matrix contained no PGML. As the duration of current-pretreatment and current density increased, flux increased. PGML increased the average passive flux markedly, about 6 to 12 folds, depending on the concentration in the patch. Current pretreatment further increased the flux from this PGML containing patch, exhibiting additive effect. These results indicate that short-duration current pretreatment of skin can be an useful method for the enhancement of ketoprofen permeability through skin.

조동의 전류효율에 미치는 직류 및 가변전류의 영향 (The Effect of Direct and Variable Current on Current Efficiency of Copper Anode)

  • 안승천;이상문;김용환;정원섭
    • 한국표면공학회지
    • /
    • 제39권5호
    • /
    • pp.223-228
    • /
    • 2006
  • The current efficiency of copper anode containing impurities in copper sulfate solution for electrorefining was studied at various current type such as direct current, variable current and periodic reverse current. The passivity behavior was investigated by galvanostatic technique. The results obtained were that current efficiency of variable current was higher than those of direct current and periodic reverse current. The increased current efficiency could be explained by the formation of slime structure with lower average resistance due to variable current. The frequency of various factors in variable current condition has a greatest effect on current efficiency. It appeared that frequency increased current efficiency when increased from 1 to 4, but further increases did not have an effect.

도체의 배열 및 전류방향이 코일형 한류소자의 교류손실 특성에 미치는 영향 (Effect of Conductor's Arrangement and Current Direction on AC Loss Characteristics of a Fault Current Limiting Coil)

  • 마용호;류경우;박권배;오일성
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.17-20
    • /
    • 2005
  • AC loss of a high $T_c$ superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in the power systems. Therefore, several samples of the fault current limiting coils have been fabricated and the effect of conductor's arrangement and current direction on AC loss characteristics investigated experimentally The test result shows that the AC losses measured in the fault current limiting coils depend significantly on the conductor's arrangement. Futhermore, they are also considerably influenced by the conductor's current direction. The AC loss measured in the face-to-face arrangement is smallest among the fault current limiting coil samples.

전통적(傳統的) 감가상각방법(減價償却方法)과 시가상각방법(時價償却方法)에 대한 비판적(批判的) 연구(硏究) - Inflation 시(時)를 중심(中心)으로 - (A Comparative Study on the Traditional Depreciation Method and Depreciation on Current Cost Basis Method)

  • 박경락
    • 산학경영연구
    • /
    • 제3권
    • /
    • pp.183-210
    • /
    • 1990
  • In this study traditional depreciation method has been analysed carefully and then compared with the depreciation on current cost basis for the purpose of reviewing the basic theory underlying depreciation on current cost basis in view of the current situation demanding new method of depreciation. In this treatise the inevitability of rejecting the basic theory of depreciation and traditional depreciation method has been treated. Furthermore the probable consequence when such refutation of traditional depreciation occurs is studied. How to resolve such problems and what is the basis for claiming for depreciation on current cost basis have been also analysed. Through this analysis and research the following conclusions have been drawn: 1. For the purpose of complete recovery of invested capital depreciation on current cost basis is demanded. 2. For the purpose of undertaking realistic profit computation and accounting to apply to comparison and analysis of business operation depreciation on current cost basis is required. 3. When the feasibility of depreciation on current cost basis is guaranteed' then depreciation on current cost basis can be promoted. 4. Depreciation on current cost basis should be studied from the standpoint of evaluation position.

  • PDF

무유도성 초전도전류제한기의 특성 해석 및 컴퓨터 시뮬레이션 (The Computer Simulation on the Characteristics of the Non-Inductive Superconducting Fault Current Limiter)

  • 주민석;이상진;오윤상;고태국
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1050-1060
    • /
    • 1994
  • This paper is a study on the computer simulation of the characteristics of the superconducting fault current limiter. Input variable parameters are apparent power, load resistance value, line resistance value and so on. Initial fault current 2 times larger than the trigger current is required to reduce the switching time of SFCL. The propagation velocity increases abruptly, the transport current is several times larger than the ciritical current. In this paper, the switching time is calculated to be 323$\mu$ sec, and the initial fault current is 19 times larger than the critical current. Because the trigger coils are bifilar winding, they have little impedance in superconducting state. After fault occurred, the limiting coil acts as a superconducting reactor and the trigger coils quench at a critical current. Without the SFCL in the circuit, fault current after the load impedence is shorted might be increased to 1100A. The fault current is, therefore, successfully limited by the superconducting limiting coil to 100A determined by the coil inductance.

  • PDF

아말감과 금합금의 Galvanic 전류 측정에 관한 실험적 연구 (A STUDY ON THE GALVANIC CURRENT BETWEEN GOLD AND AMALGAM)

  • 김영남;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.63-70
    • /
    • 1984
  • It was the purpose of this study to determine the galvanic current between a gold alloy inlay and four types of amalgam using the circuit through pulp chambers when the freshly extracted teeth with those restorations were brought into contact in a physiologic saline solution, and to investigate the effectiveness of cavity varnish or ammonated silver-nitrate on the surface of amalgam restoration in reducing galvanic current. The current was measured with current-to-voltage converter and recored on a physiograph 6630-257. The following results were obtained. 1. Generally, galvanic current decreased as the time elapsed. 2. Galvainc current decreased significantly in the first day and after then minimal change was observed until 30th day. 3. Initial galvanic current was 29.6 ${\mu}A$ in the cut amalgam and 24.5 ${\mu}A$ in Dispersalloy amalgam and after then the current was significantly decreased. 4. Initial galvanic current was 12.6 ${\mu}A$ in spherical amalgam (low copper amalgam) and 13.8 ${\mu}A$ in Tytin amalgam and the amount of change was lower in sperical amalgam and Tytin amalgam than that in lathe cut amalgam and Dispersalloy amalgam. 5. Painting ammoniated silver-nitrate or Copalite on the surface of amalgam resotration decreased initial galvanic current and ammoniated silver-nitrate is more effective in decreasing galvanic current than Copalite. 6. Galvanic current by contact between amalgam restoration and gold restoration increased abruptly and dropped rapidly becoming almost.

  • PDF

피크전류제한 설정에 따른 피크전류제한 기능을 갖는 자속구속형 초전도한류기의 고장전류제한 특성 분석 (Analysis on Fault Current Limiting Characteristics According to Peak Current Limiting Setting of a Flux-Lock Type SFCL with Peak Current Limiting Function)

  • 고석철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.68-73
    • /
    • 2012
  • In this paper, the fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) with peak current limiting function were analyzed through its short-circuit tests. The setting condition for the peak current limiting operation was derived from its electrical equivalent circuit, which was dependent on the inductance ratio between the third coil and the first coil. Through the analysis on the short-circuit tests for the flux-lock type SFCLs with the different inductance ratio between the third coil and the first coil, the setting value for the peak current limiting operation of the flux-lock type SFCL with peak current limiting function could be confirmed to be adjusted with the variation of the inductance ratio between the third coil and the first coil.

고온 초전도 케이블의 전류 분포 및 전기절연 특성 (The Characteristics of Current Distribution and Electrical Insulation on High-Tc Superconducting Cable)

  • 김영석;곽동순;한철수;김상현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.271-277
    • /
    • 2003
  • It is important to control layer current distributions of coaxial multi-layer HTS cables, because a homogeneous layer current distribution decreases AC loss and can supply the largest operational current. We have extended the theory that treat the operational current more than the critical current by considering V-I nonlinear characteristics of HTS tapes including flux flow resistance and contacting resistance between the cable and terminals. It is important to investigate the current distribution under the condition of operational current more than the critical current of cable, because the cable has experiences of fault current. In order to verify the extended theory, we have fabricated a two layers cable with the same twisting layer pitch. It was observed that almost all the operational current less than the critical current flowed on the outer layer because of its lower inductance. In case of operational current more than critical currents of layers, the flux flow resistances affect strongly current waveform and thereby the currents of layers were determined by the flux flow resistances. And we investigated breakdown characteristics in $LN_{2}$/paper composite insulation system for the application to a HTS cable. In this experiment, we got some information out of that the electrical characteristics of the insulation materials depends on the condition of butt gap.

수치모의를 통한 유사제트-파랑의 상호작용 해석 (Analysis of Interaction of Jet-like Current and Wave using Numerical Simulation)

  • 최준우;배재석;노민;윤성범
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.675-678
    • /
    • 2008
  • The effect of wave and current interactions on jet-like current flowing against waves was investigated based on numerical simulations. The numerical simulations are conducted by a combined model system of REF/DIF(a wave model) plus SHORECIRC(a current model) and a Boussinesq equation model, FUNWAVE. In the simulations, regular and irregular waves refracted due to the jet-like opposing current were focused along the core region of current, and the jet-like current was earlier spreaded when the waves had larger wave heights. The numerical results show that the rapid change of wave height distribution in transverse direction near current inlet plays a significant role to spread the jet-like current. In other words, the gradients of radiation stress forcing in transverse direction have a more significant effect on the jet-like current than its relatively small gradients forcing in flowing direction, which tend to accelerate the current, do. In conclusion, it is indispensible to take into account the interaction effect of wave transformation and current characteristics when waves meet the opposing jet-like current such as river mouth.

  • PDF

A Fast Response Integrated Current-Sensing Circuit for Peak-Current-Mode Buck Regulator

  • Ha, Jung-Woo;Park, Byeong-Ha;Kong, Bai-Sun;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권6호
    • /
    • pp.810-817
    • /
    • 2014
  • An on-chip current sensor with fast response time for the peak-current-mode buck regulator is proposed. The initial operating points of the peak current sensor are determined in advance by the valley current level, which is sensed by a valley current sensor. As a result, the proposed current sensor achieves a fast response time of less than 20 ns, and a sensing accuracy of over 90%. Applying the proposed current sensor, the peak-current-mode buck regulator for the mobile application is realized with an operating frequency of 2 MHz, an output voltage of 0.8 V, a maximum load current of 500 mA, and a peak efficiency of over 83%.