• Title/Summary/Keyword: Operating frequency

Search Result 2,843, Processing Time 0.042 seconds

Study of the Dependency of the Stirling Cryocooler′s Thermodynamic Performance on the Operating Frequency (스터링 극저온 냉동기 성능의 운전주파수 의존성에 관한 연구)

  • 홍용주;박성제;김효봉;유병건;최영돈
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.140-144
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stirling cryocooler has been widely used for the cooling infrared and cryo-sensor. The thermodynamic performance of the free piston and free displacer type (FPFD) Stirling cryocooler is highly dependent on the operating frequency of the linear compressor and the natural frequency of the displacer. In this study, to find optimal relation between operating and natural frequency of the displacer the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stifling cryocooler has maximum cooling capacity at the operating frequency of about 0.8 times of the natural frequency of displacer. Therefore the operating frequency of the Stirring cryocooler should be determined by natural frequency of the linear compressor and displacer.

An experimental study of the overall characteristics in an aero-valved pulsating combustor (空氣밸브型 脈動燃燒器의 特性에 관한 實驗的 硏究)

  • 오상헌;최병륜;임광열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.271-278
    • /
    • 1987
  • The experimental study was carried out to investigate the pressure fluctuation, operating frequency, noise emission and combustion characteristics in an aero-valved pulsating combustor. Measurements of the pressure fluctuation, mean temperature and ion current inside the combustion chamber indicate that combustion phenomena are characteristically similar to those in the diffusion flame. The measured frequency schedue indicates that the acoustic theory of the quarter wave tube can be approximated to give the operating frequency, but correction factor must be involved to estimate the correct operating frequency. The spectral behavior of the noise emission exhibits that frequency bands with high noise intensity are narrowly restricted to the neighborhood of the operating frequency signalling the low-frequency combustion characteristics of the pulsating combustor. Measurements of the operating characteristics as variation of the fuel nozzle diameter and injection angle with 4 fuel nozzles have been made, and it was found that the system produced the stable operating conditions up to the turn down ratio of 3 when the fuel nozzle diameter is 1.2mm, and the optimum fuel injection angle is thought to be in the neighborhood of 30.deg. radially.

The effect of the charging pressure and operating frequency in the Stirling Cryocooler (충전압력 및 작동주파수 특성 연구에 의한 스터링 냉동기 개발)

  • 박성제;홍용주;김효봉;고득용;김양훈;유병건;이기백
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.62-68
    • /
    • 2001
  • This paper presents manufacturing process and test results in the optimum pressure and operating frequency for the free piston free displacer(FPFD) Stirling cryocooler designed and manufactured by Korea Institute of Machinery &Materials (KIMM). FPFD Stirling cryocooler is currently under development uses opposed linear motors to drive opposed pistons . The performance of FPFD Stirling cryocooler is evaluated as a function fo charging pressure and operating frequency. In general as the operating frequency of the compressor is increaed but natural frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49K and cooling capacity of 0.5W at 7.2K.

  • PDF

A new broadband energy harvester using propped cantilever beam with variable overhang

  • Usharani, R.;Uma, G.;Umapathy, M.;Choi, S.B.
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.567-576
    • /
    • 2017
  • Design of piezoelectric energy harvester for a wide operating frequency range is a challenging problem and is currently being investigated by many researchers. Widening the operating frequency is required, as the energy is harvested from ambient source of vibration which consists of spectrum of frequency. This paper presents a new technique to increase the operating frequency range which is achieved by designing a harvester featured by a propped cantilever beam with variable over hang length. The proposed piezoelectric energy harvester is modeled analytically using Euler Bernoulli beam theory and the effectiveness of the harvester is demonstrated through experimentation. The results from analytical model and from experimentation reveal that the proposed energy harvester generates an open circuit output voltage ranging from 36.43 V to 11.94 V for the frequency range of 27.24 Hz to 48.47 Hz. The proposed harvester produces continuously varying output voltage and power in the broadened operating frequency range.

Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter (Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계)

  • Baek, Seung-Hyuk;Kim, Sungmin;Lee, Jaehong;Lee, Seung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

The Development of the Temperature Compensation Equipment to minimize Error in the Wireless Transmission System at 60GHz Band (60GHz대역 무선통신장애 해결을 위한 온도보상장치 개발)

  • Myung, Byung-Soo;Ku, Seong-Deag
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.2
    • /
    • pp.97-104
    • /
    • 2005
  • Usually, propagation attenuation of millimeter wave occurs by rainfall, snowfall, temperature, effect of pressure of air. In 60GHz wave band wireless communication network, temperature change becomes big factor of propagation loss department. Also, temperature change causes disturbance of 60GHz frequency at transceiver. In this study, we used 60GHz transceiver and found propagation loss of wireless path and operating frequency disturbance characteristics. In transceiver that there is no temperature compensated device, operating frequency of TX changed by 60.865GHz at temperature of $-5^{\circ}C$, and appeared by 60.730GHz when is $50^{\circ}C$. Therefore, operating frequency change width by temperature change are about 100MHz, greatly. But, in transceiver that there is temperature compensated device, operating frequency of TX changed by 60.830GHz at temperature of $-5^{\circ}C$, and appeared by 60.710GHz when is $50^{\circ}C$. Therefore, operating frequency change width by temperature change are about 20MHz. According to these result, we constructed between buildings examination wireless site for point to point wireless communication using 60GHz band transceivers who have do temperature compensated device, and investigated data transmission characteristics about ambient temperature change. Therefore, if use transceiver that have temperature compensated device, may overcome the wireless transmission error in 60GHz band wireless communication LAN networks despite of ambient temperature change.

  • PDF

Analysis of Frequency Property for Optimal Operating Conditions of Mono-crystalline Si Solar Cell (단결정 실리콘 태양전지 최적 운전조건을 위한 주파수 특성 분석)

  • Kim, Ji-Woong;Choi, Yong-Sung;Lee, Gyung-Sub;Cho, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2060-2060
    • /
    • 2011
  • This paper was investigated the frequency property for optimal operating conditions of mono-crystalline Si solar cell. An internal impedance of mono-crystalline Si solar cell was influenced frequency. An optimal operating conditions of solar cell was under about 10[kHz].

  • PDF

Miniaturized Frequency Selective Surface with a Scalability of Operating Frequency (동작 주파수 확장성을 갖는 소형화된 주파수 선택 표면구조 설계)

  • Lee, In-Gon;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.512-520
    • /
    • 2016
  • In this paper, a miniaturized frequency selective surface(FSS) for bandstop operation that provides stability for an angle of incidence and polarization is presented. The proposed miniaturized FSS has the unit cell of hexagonal structure with triangular loops and size of the unit cell is $0.081{\lambda}{\times}0.081{\lambda}$ at 2.5 GHz operating frequency, which is very small compared to operating wavelength. In addition, unlike the conventional design, which requires complicated design parameters, the proposed FSS is easily expanded to the desired operating frequency for 2~8 GHz, by controlling the specific design parameters. To validate the simulation results, the FSS structures having different operating frequencies, 2.5 GHz, 5 GHz and 8.2 GHz were designed, fabricated and measured. The comparisons between the simulation and the measured results show good agreement. The proposed miniaturized FSS can provide better frequency stability for different incidence angles and polarizations.

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

A Study on Pressure Surge Accompanied by Repeated Valve Operation in Oil Hydraulic Pipeline (유압관로에서 절환밸브 반복조작에 따른 충격압력 발생 현상에 관한 연구)

  • Jung, Yong-Gil;Yum, Man-U;Lee, Jin-Geol;Lee, Il-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.2
    • /
    • pp.33-42
    • /
    • 1988
  • In a large scale oil hydraulic system having repeatedly operated actuator, such as a large scale forging press, pressure surges often due to the recombination of oil column in a return line attached to the downstream side of a directional control valve. Expecially, the pressure surges appear very severe ones at a certain valve operating frequency. These pressure surges restrict the operating frequency of the hydraulic system. But related reports on the above mentioned phenomenon are rarely to be found. In this study, therefore, the authors investigate the exact reason why such severe pressure surges occur at a certain range of valve operating frequency. The study is performed by experiment and numerical computation on the relationship between pressure surges and valve operating frequency.

  • PDF