• Title/Summary/Keyword: Operating parameter

Search Result 799, Processing Time 0.028 seconds

Fault Detection in an Automatic Central Air-Handling Unit (자동 공조설비의 고장 검출 기술)

  • Lee, Won-Yong;Shin, Dong-Ryul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.410-418
    • /
    • 1999
  • This paper describes the use of residual and parameter identification methods for fault detection in an air handling unit. Faults can be detected by comparing expected condition with the measured faulty data using residuals. Faults can also be detected by examining unmeasurable parameter changes in a model of a controlled system using a system identification technique. In this study, AutoRegressive Moving Average with seXtrnal input(ARMAX) and AutoRegressive with eXternal input(ARX) models with both single-input/single-input and multi-input/single-input structures are examined. Model parameters are determined using the Kalman filter recursive identification method. Regression equations are calculated from normal experimental data and are used to compute expected operating variables. These approaches are tested using experimental data from a laboratory's variable-air-volume air-handling-unit.

  • PDF

A Study on Reliability Analysis & Determination of Replacement Cycle of the Railway Vehicle Contactor (철도차량 접촉기의 신뢰성 분석 및 교환주기 결정에 대한 연구)

  • Park, Minheung;Rhee, Sehun
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.316-324
    • /
    • 2017
  • Purpose: The purpose of this study is to determine the replacement cycle applied age replacement policy by reliability analysis based on railway vehicle contactor's failure history data. Method: We performed reliability analysis based on railway vehicle contactor's failure history data. We found a suitable distribution by goodness of fit test and predicted the reliability through estimation of scale & shape parameter. Considering cost information we determined the replacement cycle that minimize the opportunity cost. Result: Suitable distribution was the Weibull and scale parameter & shape parameter are estimated by reliability analysis. The replacement cycle was predicted and MTTF, $B_6$ percentile life were suggested additionally. Conclusion: We confirmed that failure rate type of railway vehicle contactor is degradation model having a time dependent characteristic and examined the replacement cycle in our country's operating environment. We expect that this study result contribute to railway operation agency for maintenance policy decision.

Operating characteristics of an air cooling PEMFC for portable application (이동 전원용 공랭식 고분자 연료전지의 제작 및 운전 특성 연구)

  • Sohn Young-Jun;Park Gu-Gon;Yang Tae-Hyun;Yoon Young-Gi;Lee Won-Yong;Yim Sung-Dae;Kim Chang-Soo
    • New & Renewable Energy
    • /
    • v.1 no.1 s.1
    • /
    • pp.72-78
    • /
    • 2005
  • Optimal design and proper operation are important to get aimed output power of a polymer electrolyte membrane fuel cell (PEMFC) stack. An air cooling fuel cell stack is widely used in sub kW PEMFC systems. The purpose of this study is to analyze operating conditions affecting the performance of the air cooling PEMFC which is designed for portable application. In portable applications, air cooling stack is difficult to maintain well balanced operating conditions. The importart parameters are the relative humidity, the temperature of the stack, the utilization of reactant gas and so on. in this study, a 500W air cooling PEMFC was fabricated and tested to evaluate the design performance and to determine optimal operating conditions. Moreover, basic modeling also is carried out. These results can be used 3s design criteria and optimal operating conditions for portable PEMFCs

  • PDF

Characterization of the Effect of the Inlet Operating Conditions on the Performance of Lean Premixed Gas Turbine Combustors

  • Samperio, J.L.;Santavicca, D.A.;Lee, J.G.
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.10-18
    • /
    • 2004
  • An experimental study of the effect of operating conditions on the behavior of a lean premixed laboratory combustor operating on natural gas has been conducted. Measurements were made characterizing the pressure fluctuations in the combustor and the flame structure over a range of inlet temperatures, inlet velocities and equivalence ratios. In addition the fuel distribution at the inlet to the combustor was varied such that it was an independent parameter in the experiment. Inlet temperature, inlet velocity and equivalence ratio were all found to have an effect on the stability characteristics of the combustor. The nature of this effect, however, depended on the fuel distribution. For example, with one fuel distribution the combustor would become unstable when the temperature was increased, whereas with a different fuel distribution the combustor would become unstable when the temperature was decreased. Similarly, the operating conditions had an effect on the flame structure. For example the intensity-weighted center of mass of the flame was found to move closer to the center body as either the temperature or equivalence ratio increased. It was interesting and somewhat surprising to note, however, that as the location of the center of mass changed with operating conditions it did so by moving along a line of constant flame angle.

  • PDF

Design and characteristics of operating circuit for the LED Traffic Signal Lamp (LED 교통 신호등의 구동 회로 설계 및 특성)

  • No, Kyung-Ho;Lim, Byoung-No;Park, Jong-Yeun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.106-110
    • /
    • 2005
  • In this paper, LED traffic signal lamp's operating circuit using Flyback converter and PFC IC has been presented. Most power conversion circuits use PFC IC for Power Factor Correction. The design parameter's value of Flyback converter has been proposed and the error amplifier which regulates the output voltage has been designed Besides, the under voltage protection circuit and the over voltage protection circuit for protecting the operating circuit kin unbalance of common electric power source and the temperature compensation circuit for fixed optical output power have been proposed.

  • PDF

Decision Support Tool for Evaluating Push and Pull Strategies in the Flow Shop with a Bottleneck Resource

  • Chiadamrong, N.;Techalert, T.;Pichalai, A.
    • Industrial Engineering and Management Systems
    • /
    • v.6 no.1
    • /
    • pp.83-93
    • /
    • 2007
  • This paper gives an attempt to build a decision support tool linked with a simulation software called ARENA for evaluating and comparing the performance of the push and pull material driven strategies operating in the flow shop environment with a bottleneck resource as the shop's constraint. To be fair for such evaluation, the comparison must be made fairly under the optimal setting of both systems' operating parameters. In this study, an optimal-seeking heuristic algorithm, Genetic Algorithm (GA), is employed to suggest a systems' best design based on the economic consideration, which is the profit generated from the system. Results from the study have revealed interesting outcomes, letting us know the strength and weakness of the push and pull mechanisms as well as the effect of each operating parameter to the overall system's financial performance.

A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests (Weil-Dobke 합성단락시험로의 최적화 연구)

  • 김맹현;고희석
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

A Study on Prediction of Die Life of Warm Forging by Wear(I) -Construction of Die Wear Model- (마멸에 의한 온간단조의 금형수명 예측에 관한 연구(I) -금형 마멸 모델의 정립-)

  • 강종훈;박인우;제진수;강성수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.03a
    • /
    • pp.88-93
    • /
    • 1998
  • The service life of tools in metal forming process is to a large extent limited by wear, fatigue fracture and plastic deformation. In warm forging processes wear is the predominant factor for operating lives of tools. To predict tool life by wear, Archard's wear model is generally applied. Usually hardness of die is considered to be a function of temperature in Archard's wear model. But hardness of die is a function of not only temperature but also operating time of die. To consider softening of die by repeated operations, it is necessary to express hardness of dies by a function of temperatures and operating time. By experiment of reheating of dies, die softening curves were obtained. Finally modified Archard's wear model in which hardness of die was expressed as a function of main tempering curve was proposed.

  • PDF

Design of a ControLler for Level Control System Using Adaptive Control (적응제어기법을 이용한 레벨제어시스템의 제어기 설계)

  • 소명옥;정재학;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.5
    • /
    • pp.54-62
    • /
    • 1993
  • Generally, the main difficulty in the composition of tank-level control system may be in the point that plant parameters are severely varied according to the change of operating point. In order to cope with this difficulty, in this paper, an adaptive control is employed using model-following technique based on the optimal control law. Through the simulations and experiments the following results were observed. 1) The steady-state error was not found under the parameter variations caused by the change of operating point. 2) In spite of the change of operating point, the corresponding gains which were stored in the computer were found to be automatically updated so that the controller could have the adaptive ability. And also, the control specifications in view of transient response were found to be satisfied.

  • PDF

Robust Control of Permanent Magnet Synchronous Motor using Fuzzy Logic Controller (퍼지논리 제어기를 이용한 영구자석 동기전동기의 강인성 제어)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Chae, So-Hyung;Kim, Chun-Sam;Yoo, Bo-Min
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1228-1230
    • /
    • 1992
  • The permanent magnet synchronous motor(PMSM) is receiving Increased attention for servo drive applications in recent years because of its high torque to inertia ratio, superior power density and high efficiency. By vector-controll method, PMSM has the same operating characterics as seperately excited dc motor. The drive system of servo motor is requested to have an accurate response for the reference input and a quick recovery for the disturbance such as load torque. However, when the unknown disturbances and parameter variations are imposed on the permanent magnet synchronous motor(PMSM), the drive system is significantly effected by them. As a result, the drive system with both a fast compensation and a robustness to a parameter variations is requested. This paper investigates the possibility of applying the fuzzy logic controller(FLC) using Multi-Rule Base In a servo motor control system. In this paper, The five Rule Bases(1 to 5) are selected to recover the state error caused by the disturbance in steady state. In the initial operating mode. Rule Base 0 is used. To show the validity of the proposed fuzzy logic controll system, the computer simulation results are provided.

  • PDF