• Title/Summary/Keyword: Operation guideline

Search Result 408, Processing Time 0.031 seconds

Development and Evaluation of the Web-based Evidence-based Practice Guideline for the Operation Patients (수술환자를 위한 웹 기반 근거중심 실무 가이드라인의 개발 및 평가)

  • Hong, Sung-Jung;Chang, Jae-Sik;Jeon, Young-Hoon;Lee, Eun-Joo;Kim, Hwa-Sun
    • Journal of Internet Computing and Services
    • /
    • v.12 no.1
    • /
    • pp.131-139
    • /
    • 2011
  • The purpose of this research is to evaluate patient's satisfaction and clinician' knowledge level about pain, nausea, vomiting, and temperature management of patients after operation by develop an web-based evidence-based practice guideline about pain, nausea, vomiting, and temperature control after operation in order to apply the guideline operation patients. The collected data was analyzed through real number, average, standard deviation, t-test and repeated ANOVA by using SPSS/WIN 17.0 program. The study subjects showed a significant difference in the level of knowledge about pain, nausea/vomiting, and temperature control after operation and patient's satisfaction, before and after applying the web-based evidence-based practice guideline.

A Study on the Development of Safety Operation Guideline for Onboard A-Frame System Using Dynamic Simulation (동역학 시뮬레이션 기반 선박 A-Frame의 안전 운용 가이드 개발 연구)

  • Oh, Jae-Won;Kim, Hyung-Woo;Kwon, O-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.625-633
    • /
    • 2021
  • This paper considers the development of safety operation guideline for onboard A-Frame system used to operate heavy-work ROV using dynamic simulation. Onboard A-Frame is affected by ship's behavior and large inertia by the marine environment. For this reason, safety operation guidelines are required for the safety of workers who operate ship-mounted equipment. In order to develop a guideline, it is necessary to evaluate the safety loads through real sea experiment. However, simulation method is used instead since it is difficult to conduct experiments in sea. Therefore, a procedure for safety operation analysis based on dynamic simulation that can consider ship behavior and marine environment and a safety operation table were proposed in this study. And the construction of safety operation table and guide for safety operation using the applied load and safety factor analysis results were considered.

A Study on the Architectural Design Guideline for Intensive Care Unit - Focused on Cases of The US, The UK and Australia (중환자부 시설기준 수립을 위한 가이드라인 조사·분석연구 - 미국, 영국, 호주 사례를 중심으로)

  • Yun, Woo Young;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.4
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose: At the moment, There is a facility standard for intensive care units on the Korea medical services Act. However, the contents of regulation are so limited and difficult to apply. Therefore, it is necessary to draw up the guideline to complement the regulation for efficient operation of intensive care units. This study aims to suggest basic data for guideline of intensive care units. Methods: 2 Methods have been used in this paper. 1) Comparative analysis between the national regulation of Korea with the design standard of the United States America, the United Kingdom and Australia. 2) A literature survey about operation method for intensive care unit, focused on materials published in intensive care medicine society of each country. Results: In comparison with guideline of abroad cases, additional supplement are required, with regard to item such as operation environment, size, nursing manpower ratio, bed space area, space program of intensive care units for healing environment. Implications: This study is a basic research for guideline of intensive care unit, and need to be followed by further study using various perspectives and methods.

Suggestion of a New Writer's Guideline to Reduce Human Errors Found in the Emergency Operation Procedures of a Nuclear Power Plant (비상운전절차서 작성과정의 인적오류 저감을 위한 지침서 제안에 관한 연구)

  • Lee, Dhong-Ha;Jang, Tong-Il;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.129-138
    • /
    • 2010
  • Gori-I nuclear power plant has been examining the effectiveness and efficiency of the current emergency operation procedures from human factors viewpoint. Previous study showed that some mistakes that the procedures did not comply with the writers' guidelines. Reviewing the current writers' guidelines for emergency operating procedures revealed that they lack of some important human factors rules such as enumeration of switching conditions and detailed action requirements, definite expression for setup points, description for anticipated results, and recommendation for use of present tense, affirmative sentence and active voice. This study suggested a new classification system for the writers' guideline contents supplementing the deficiencies of the current emergency operation procedure text.

A Study for Small Cogeneration System Intertie (소형열병합 발전설비 계통연계 상용운전에 관한 연구)

  • Park, K.W.;Kim, W.T.;Yoon, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.166-168
    • /
    • 2001
  • Generation by the privately owned generators, which are normally operated has occupied about 10% of total generation. Recently the small co-generation employed gas engine has been introduced and attracted public interest. For privately owned generator to be paralleled Utilities, a customer complies with Generator Parallel Operation Guideline set by Utilities and installs related protective relays. But the guideline is not specified to small co-generation, only provides parallel operation of privately owned generator. So applying this guideline, initial investment can be too high comparing to total co-generation cost. Besides there is no specified guide about ALTS, which arises asynchronous problem. In this paper we analyzed guideline and technical problem when small co-generation is paralleled. And additionally needed researching area to improve distribution of small co-generation is discussed.

  • PDF

Assessment guideline for the safe use of metalworking fluids - Focused on water-soluble metalworking fluids (기계가공 공정에서 금속가공유 관리에 대한 평가지침 -수용성 금속가공유를 중심으로-)

  • Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.131-138
    • /
    • 2010
  • This technical report was developed to suggest the guideline to assess the safe use and handling metalworking fluids (MWFs) in machining operation. The basis of this method developed in this study was based on self assessment procedure recommended by Organization Resources Counselors (ORC) of the United States (US). In addition, various MWF management elements obtained from the review on various articles, reports and author's experience regarding MWF were newly added to the evaluation guideline. A total of four areas were finally selected in order to control exposure to MWF used in machining operations. They are all related to the presence and efficiency of the control measures, exposure assessment, management on tank and sump, and safe treatment of chips and metal fines generated during machining operations. Each area is consisted of several related elements. Several evaluation areas and elements used in this study could be revised, replaced, added and deleted according to the process environment, evaluation objectives and evaluator's (manager) criteria etc. This evaluation guide manual could be used for safe management of MWF in metalworking operation. In addition, industrial hygienists can use this evaluation method for auditing and evaluating the management status on MWF.

Developing Living and Managing Guidelines for the Sustainability of Back-to-Farm Community Village (귀촌형 공동체마을 지속성을 위한 생활 및 관리 가이드라인 개발)

  • Park, Kyoung-Ok;Lee, Sang-Un
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.1-9
    • /
    • 2018
  • The purpose of this study was to develop guidelines for sustainability of back-to-farm community village in 4 aspects; social environment, maintenance and management, regional environment, and economic environment. These 4 aspects, which count for sustainability, based on the comprehensive comparative analysis about items that field survey and literature suggested. Conclusions of guideline are of the following. The guidelines on social environment are developed by 3 items; resident participation and activity, village leader, decision making in village and person in charge of operation. The guidelines on maintenance and management are developed by 5 items; village operation system, village regulation, transparency of management, village operation expenses, and management type. The guidelines on regional environment are developed by 2 items; support by central and local government, and area projects and connection to regional resources. The guideline on economic environment is not developed due to low demands of based production facilities and income increase facilities.

The Foodservice Sanitation Status of the Child Care Centers at Asan City in Chungnam (영.유아 보육시설의 급식 위생실태 - 충남 아산 지역 중심으로 -)

  • Song, Eun-Seung;Kim, Eun-Gyung
    • Korean Journal of Community Nutrition
    • /
    • v.15 no.6
    • /
    • pp.806-819
    • /
    • 2010
  • We investigated the foodservice sanitation status of the childcare centers in Chungnam Asan area to provide the information for sanitation guidelines and checklist in various operation types of childcare centers. Self-completed questionnaires were collected from the directors of 95 centers: national-public 9 (9.5%), corporation 10 (10.5%), private 52 (54.7%), and home care 24 (25.3%) types. The analyzed results are shown in foundation type; the investigated items are about critical hygienic problems and safety recognition level, presence of sanitation guideline, demand of dietian's employment and the role, hygienic management and education level, and the present and future of sanitary facility and equipment. From this study we found that home care center, which had low capacity, was comparatively poor at sanitation status, the use of hygienic standard and guideline, and safety recognition level. In our opinion, the use and application of same sanitation standard to any type and size of center is not appropriate and rational. The reestablishment of the sanitation guideline and checklist considering the conditions of various operation types would be necessary. Also periodic hygienic education by hygenic professionals, continuous parents' attention and cooperation of related government organizations are needed for improvement of foodservice sanitation status of childcare centers.

Development of mobile vehicle designed by the guideline of wall-climbing mobile robot using permanent magnetic wheels (영구자석바퀴를 이용한 벽면 이동로봇의 설계치침에 의한 이동체 개발)

  • 한승철;이화조;김은찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1676-1681
    • /
    • 2003
  • The attachment of mobile vehicle is necessary for the automated operation on the inclined or vertical walls of steel structures. Since the vehicle requires attaching devices additionally, its overall efficiency can be reduced by the devices. Therefore, external shapes of mobile vehicles have to be researched to give the effective movement on the vertical face. For the design of mobile vehicle, the guideline has been derived from the modeling of wall-climbing, so that the vehicle should have a specific external shape for vertical movement due to the gravitational force. Hence, some adequate arrangement of attaching device to the mobile vehicle has been presented for the effective movement. In the experiments with four permanent magnetic wheels, a plausible result was achieved as a vertical attaching force of 185.2(N), a friction force of 153.8(N) and a curvature radius of 1.4m. The mobile vehicle should be modified according to the proposed design guideline. and then it could be applied to a specific operation as an appropriate external shape. Also, Further research is recommended on an optimal posture and a moving method in a specific application. as the attaching force ortho vehicle can be affected by its posture.

  • PDF

A Study on Establishment of Technical Guideline of the Installation and Operation for the Efficient Bio-gasification Facility of Pig Manure and Food Waste(III): Design and Operation Guideline (가축분뇨 병합처리 바이오가스화를 위한 설계 및 운전 기술지침 마련 연구(III) 설계 및 운전 지침(안) 중심으로)

  • Lee, Dongjin;Moon, HeeSung;Son, Jihwan;Bae, Jisu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.99-111
    • /
    • 2017
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to bio-gasification facilities treating organic wastes. Based on the results obtained during the field surveys, the overall design and operation guidelines for bio-gasification facilities, monitoring items, cycle and commissioning period were presented. According to the flow of anaerobic digestion process, Various design factors for bio-gasification facilities were proposed in this study. When designing the initial anaerobic digestion capacity, 10 ~ 30% of the treatment capacity was applied considering the discharge characteristics by the incoming organic wastes. At the import storage hopper process, limit concentration of transporting organic wastes was limited to TS 10 % or less, and limit concentration of inhibiting factor was suggested in operation of anaerobic digester. In addition, organic loading rate (OLR) was shown as $1.5{\sim}4.0kgVS_{in}/(m^3{\cdot}day)$ for the combined bio-gasification facilities of animal manure and food wastes. Desulfurization and dehumidification methods of biogas from anaerobic digestor and proper periods of liquifization tank were suggested in design guideline. It is recommended that the operating parameters of the biogasification facilities to be maintained at pH (acid fermentation tank 4.5~6.5, methane fermentation tank 6.0~8.0), temperature variation range within $2^{\circ}C$, management of volatile fatty acid and ammonia concentration less than 3,000 mg/L, respectively.