• Title/Summary/Keyword: Optimal waveform selection

Search Result 6, Processing Time 0.026 seconds

Seismic waveform tomography in the frequency-space domain: selection of the optimal temporal frequency for inversion

  • Yokota Toshiyuki;Matsushima Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2004
  • Frequency-space domain full-wave tomography is a promising technique for delineating detailed subsurface structure with high resolution. However, this method requires criteria for the selection of a set of optimal temporal frequency components, to achieve stability in the sequence of inversion processes together with computational efficiency. We propose a method of selecting optimal temporal frequencies, based on wavenumber continuity. The proposed method is tested numerically and is shown to be able to select an optimal set of frequency components that are sufficient to image the anomalies.

One-Step-Ahead Control of Waveform and Detection Threshold for Optimal Target Tracking in Clutter (클러터 환경에서 최적의 표적 추적을 위한 파형 파라미터와 검출문턱 값의 One-Step-Ahead 제어)

  • Shin Han-Seop;Hong Sun-Mog
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.31-38
    • /
    • 2006
  • In this paper, we consider one-step-ahead control of waveform parameters (pulse amplitudes and lengths, and FM sweep rate) as well as detection thresholds for optimal range and range-rate tracking in clutter. The optimal control of the combined parameter set minimizes a tracking performance index under a set of parameter constraints. The performance index includes the probability of track loss and a function of estimation error covariances. The track loss probability and the error covariance are predicted using a hybrid conditional average algorithm The effect of the false alarms and clutter interference is taken into account in the prediction. Tracking performance of the one-step-ahead control is presented for several examples and compared with a control strategy heuristically derived from a finite horizon optimization.

Real-Time PRF Selection for Search/Track in MPRF Waveform Airborne Radar (MPRF 파형을 사용하는 항공기 레이더에서 탐색/추적을 위한 실시간 PRF 선택)

  • Kim, Tae-Hyung;Kim, Eun-Hee;Lee, Sung-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.10
    • /
    • pp.1050-1061
    • /
    • 2014
  • Airborne radar usually use MPRF(medium PRF) waveforms to detect and track look-down or all-directions air-to-air targets. To use MPRF waveforms, airborne radar have to operate optimal PRF schedules and select optimal PRFs able to detect look-down air-to-air targets, overcoming look-down clutter and resolving range/velocity ambiguities. In this paper, we propose a real-time search method for the optimal(and sub-optimal) PRFs able to detect and track targets in real-time change of situation for MPRF pulsed-Doppler airborne radars.

A STUDY ON OPTIMAL DRIVING METHODS FOR IMPROVING TORQUB CHARACTERISTIC OF MINIATURE BRUSHLESS DC MOTOR (소형브러시리스 DC 전동기의 토크 특성향상을 위한 최적 구동법에 관한 연구)

  • Park, G.T.;Song, M.H.;Kim, Y.I.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.16-20
    • /
    • 1989
  • In this paper, we describe the optimal driving method and magnetic flux distribution of permanent magnet which enhance torque characteristics in small-sized 3-phase brushless DC motors. The disadvantages of conventional $120^{\circ}$ constant current drive method are torque ripple, switching noise and spike voltage due to the inductance of stator coil. This shortcommings can be avoided by the switching slew-rate of driving current which is called linear voltage driving method. The aim of this study is to analyze linear voltage driving method quantatively and to determine optimal drive current waveform through computer simulation. The selection of commutation angle and slew rate of a new driving current at switching instants makes torque ripple index minimize and average torque maximize. And the validity of this new driving method was assured by Fourier analysis. Considering two dimensional nonlinear magnetic flux distribution on the permanent magnet, we suggest optimal flux distribution according to the presented driving method which improves torque characteristics.

  • PDF

Spontaneous Oscillatory Rhythm in Retinal Activities of Two Retinal Degeneration (rd1 and rd10) Mice

  • Goo, Yong-Sook;Ahn, Kun-No;Song, Yeong-Jun;Ahn, Su-Heok;Han, Seung-Kee;Ryu, Sang-Baek;Kim, Kyung-Hwan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.15 no.6
    • /
    • pp.415-422
    • /
    • 2011
  • Previously, we reported that besides retinal ganglion cell (RGC) spike, there is ~10 Hz oscillatory rhythmic activity in local field potential (LFP) in retinal degeneration model, rd1 mice. The more recently identified rd10 mice have a later onset and slower rate of photoreceptor degeneration than the rd1 mice, providing more therapeutic potential. In this study, before adapting rd10 mice as a new animal model for our electrical stimulation study, we investigated electrical characteristics of rd10 mice. From the raw waveform of recording using $8{\times}8$ microelectrode array (MEA) from in vitro-whole mount retina, RGC spikes and LFP were isolated by using different filter setting. Fourier transform was performed for detection of frequency of bursting RGC spikes and oscillatory field potential (OFP). In rd1 mice, ~10 Hz rhythmic burst of spontaneous RGC spikes is always phase-locked with the OFP and this phase-locking property is preserved regardless of postnatal ages. However, in rd10 mice, there is a strong phase-locking tendency between the spectral peak of bursting RGC spikes (~5 Hz) and the first peak of OFP (~5 Hz) across different age groups. But this phase-locking property is not robust as in rd1 retina, but maintains for a few seconds. Since rd1 and rd10 retina show phase-locking property at different frequency (~10 Hz vs. ~5 Hz), we expect different response patterns to electrical stimulus between rd1 and rd10 retina. Therefore, to extract optimal stimulation parameters in rd10 retina, first we might define selection criteria for responding rd10 ganglion cells to electrical stimulus.

Optimum Frequency Analysis for Sonar Transmit Signal design (소나 송신신호 설계를 위한 최적 주파수 분석)

  • Kim, Sunho;Jung, Jangwon;On, Baeksan;Im, Sungbin;Seo, Iksoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.47-54
    • /
    • 2016
  • In the underwater environment, high resolution can be achieved in the range direction by transmitting and receiving a signal of a particular band and/or waveform. The design of a transmit signal used in the active sonar is very important in order to detect a cylindrical object within a short distance less than 1 km, which is the detection distance of this paper. Designing a transmit signal optimal to a sonar requires appropriate selection of its center frequency and bandwidth, which allows the maximum detection distance of a sonar. In this paper, in terms of maximizing echo excess and signal to noise ratio (SNR), optimum frequency analysis is carried out under various conditions of diverse parameters. In addition, the investigation focused on the determinating a bandwidth is also performed for the purpose of satisfying the performance requirement of range resolution and azimuth resolution.