• Title/Summary/Keyword: Orbital floor fracture

Search Result 47, Processing Time 0.026 seconds

Open Reduction and Internal Fixation (ORIF) of Trapdoor Orbital Floor Blowout Fracture with Absorbable Mesh Plate (뚜껑문 안와저 골절에 있어서 망상 흡수성 판을 이용한 관혈적 정복술 및 내고정술)

  • Kwon, Yu-Jin;Kim, Ji-Hoon;Hwang, Jae-Ha;Kim, Kwang-Seog;Lee, Sam-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.619-625
    • /
    • 2010
  • Purpose: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. Methods: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevatordepressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. Results: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. Conclusion: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.

A Case of Transorbital Orbital Floor Fracture Repair Assisted Endonasal Balloon Catheter (비내 풍선 카테터 유도하 경안와 접근법을 이용한 안와 하벽 골절 정복 1예)

  • Kim, Min Joon;Kim, Jung Suk;Park, Tae Jung;Jung, Tae Young
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.276-280
    • /
    • 2018
  • It is important to choose which approaches should be used to correct the fracture if the operation is indication for surgery in patients with orbital floor fracture. Transorbital, transantral, and endonasal approaches are methods for correcting the orbital floor fracture. The approach needs to be considered the location of the fracture, the degree, the severity of the fracture, the least remaining patient's disability, and preference of the surgeon. We report a case of orbital floor fracture using transorbital approach and endonasal catheter ballooning to resolve the limitations of transorbital approach alone.

Oculocardiac reflex in an adult with a trapdoor orbital floor fracture: case report, literature review, and differential diagnosis

  • Brasileiro, Bernardo Ferreira;Sickels, Joseph E. Van;Cunningham, Larry L. Jr.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.428-434
    • /
    • 2020
  • Orbital floor blowout fractures can result in a variety of signs and symptoms depending on the severity of the bone defect. Large defects often result in enophthalmos and restriction of ocular movement; yet the timing of surgery can be delayed up to two weeks with good functional outcomes. In contrast, an orbital trapdoor defect with entrapment of the inferior rectus muscle usually elicits pain with marked restriction of the upward gaze and activation of the oculocardiac reflex without significant dystopia or enophthalmos. When autonomic cardiac derangement is diagnosed along with an orbital floor fracture, it has been suggested that the fracture should be treated immediately. Otherwise, it will result in continued hemodynamic instability and muscular injury and may require a second surgery. This article reports the management of an unusual presentation of a trapdoor blowout orbital floor fracture surgery with oculocardiac response in an adult, with emphasis on its pathophysiology, management, and differential diagnosis.

Reconstruction of the Inferior Orbital Wall with Simplified Simulation Technique in Case of the Fracture Extending to the Posterior Orbital Floor

  • Kim, Kyu Nam;Kim, Hoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.2
    • /
    • pp.80-83
    • /
    • 2016
  • A 37-year-old male was assaulted and complained of severe periorbital swelling. Physical examination revealed that there were limitation of eyeball movement on upper gaze, diplopia, and hypoesthesia on the infraorbital nerve innervating region. Three-dimensional (3D) computed tomography (CT) of facial bone exhibited the fracture of orbital floor accompanying the significant amount of orbital contents' herniation extending to the far posterior part. To recover the orbital volume and restore orbital floor without threatening the optic nerve, preoperative simplified simulation was applied. The posterior margin of the fractured orbit was delineated with simulation technique using cross-linkage between the coronal and sagittal sections based on the referential axial view of the CT scans. Dissection, reduction of orbital contents, and insertion of the absorbable mesh plate molded after the prefabricated template by the simulation technique was performed. Extensive orbital floor defect was successfully reconstructed and there were no serious complications. The purpose of this report is to emphasize the necessity of preoperative simulation in case of restoring the extensive orbital floor defect.

Antibiotic Prophylaxis' Effect on Enophthalmos in Orbital Floor Fracture with Chronic Maxillary Sinusitis (상악동염이 있는 안와 하벽 골절에서 예방적 항생제의 중요성)

  • Sung, Hyoung Woo;Kim, Jin Woo;Shin, Han Kyung;Jung, Jae Hak;Kim, Young Hwan;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.67-71
    • /
    • 2008
  • Purpose: Orbital floor fracture has open wound to maxillary sinus and if the patient has chronic maxillary sinusitis, it may be have more risk of infection, complications. The purpose of this comparative study is to be the effectiveness of prophylactic antibiotics in orbital floor fracture with chronic maxillary sinusitis. Methods: We studied 20 patients who diagnosed as orbital floor fracture with chronic maxillary sinusitis from march, 2005 to may, 2006. Among them 16 were male, 4 were female and age was ranged from 15 to 68, average was 42. A day before operation, Prophylactic antibiotics were used to 10 patients. Prophylactic antibiotics were not used to 10 patients. We defined control group as prophylactic antibiotics injection group a day before operation. After surgery, we confined use of same antibiotic for 7 days in both group. After 6 month from surgery, we compare the degree of enophthalmos from healthy side to legion side with hertel exopthalmometry(Inami, Japan) in control group and non-prophylactic antibiotics injection group. Results: In control group, comparison of discrepancy between enophthalmic eyeball and normal eyeball with Hertel exophthalmometer was 1.1 mm and non-prophylactic antibiotics injection group was 2.1 mm. In independent sample t-test, control group was showed statistically significant difference with non-prophylactic antibiotics injection group(p=0.007). Conclusions: In orbital floor fracture with chronic maxillary sinusitis, bacteria in maxillary sinus can increase post-operative complication by infecting infraorbital soft tissue, and it is thought to be antibiotic prophylaxis is play a role in decrease in degree of enophthalmos. We feel the need to further study of prophylactic antibiotics in orbital floor fracture with chronic maxillary sinusitis.

Late reconstruction of extensive orbital floor fracture with a patient-specific implant in a bombing victim

  • Smeets, Maximiliaan;Snel, Robin;Sun, Yi;Dormaar, Titiaan;Politis, Constantinus
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • Fractures of the orbital floor and walls are among the most frequent maxillofacial fractures. Virtual three-dimensional (3D) planning and use of patient-specific implants (PSIs) could improve anatomic and functional outcomes in orbital reconstruction surgery. The presented case was a victim of a terrorist attack involving improvised explosive devices. This 58-year-old female suffered severe wounds caused by a single piece of metal from a bomb, shattering the left orbital floor and lateral orbital wall. Due to remaining hypotropia of the left eye compared to the right eye, late orbital floor reconstruction was carried out with a personalised 3D printed titanium implant. We concluded that this technique with PSI appears to be a viable method to correct complex orbital floor defects. Our research group noted good aesthetic and functional results one year after surgery. Due to the complexity of the surgery for a major bony defect of the orbital floor, it is important that the surgery be executed by experienced surgeons in the field of maxillofacial traumatology.

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

  • Jo, Eun Jun;Kim, Jong Hwan;Yang, Ho Jik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.114-118
    • /
    • 2015
  • Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.