치과 및 의료용 스테인리스강선의 표면특성 (Surface Characteristics of Stainless Steel Wire for Dental and Medical Use)

  • 최한철;고영무
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.339-346
    • /
    • 2003
  • Stainless steel wire has been used in industry, dental and medical parts. Especially, it has been used widely for the dental orthodontic materials. The orthodontic wire requires good mechanical properties, such as elastic strength, combined with a high resistance to corrosion. To increase elastic strength and good corrosion resistance, drawing methods(one-step and two-step drawing) have been used and the electrochemical characteristics of drawed wire have been researched using potentiodynamic method in 0.9%NaCl and field emission scanning electron microscope. The one-step drawed wire showed the formation of rough surface. The hardness and tensile strength of two-step drawed wire increased. For the case of two-step drawed wire, the corrosion resistance and pitting potential increased compared with one-step drawed wire due to the drawing induced small surface roughness, such as scratch. The passivation and active current density decreased as the reduction in area for drawing increased.

교정용 와이어의 표면특성에 미치는 TiN 및 ZrN 코팅영향 (Effects of TiN and ZrN Coating on Surface Characteristics of Orthodontic Wire)

  • 김원기;김도영;최한철
    • 한국표면공학회지
    • /
    • 제41권4호
    • /
    • pp.147-155
    • /
    • 2008
  • The dental orthodontic wire provides a good combination of strength, corrosion resistance and moderate cost. The purpose of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance and physical property of orthodontic wire using various instruments. Wires(round type and rectangular type) were used, respectively, for experiment. Ion plating was carried out for wire using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive X-ray spectroscopy(EDS), atomic force microscopy(AFM), vickers hardness tester, and electrochemical tester. The surface of TiN and ZrN coated wire was more smooth than that of other kinds of non-coated wire. TiN and ZrN coated surface showed higher hardness than that of non-coated surface. The corrosion potential of the TiN coated wire was comparatively high. The current density of TiN coated wire was smaller than that of non-coated wire in 0.9% NaCl solution. Pit nucleated at scratch of wire. The pitting corrosion resistance $|E_{pit}-E_{rep}|$ increased in the order of ZrN coated(300 mV), TiN coated(120 mV) and non-coated wire(0 mV).

치과 교정용 듀플렉스 스테인리스 스틸 와이어의 기계적 강도 및 세포독성 평가 (Evaluation of the Cytotoxicity and Mechanical Strength of Dental Duplex Stainless Steel Orthodontic Wire)

  • 이명곤;김치영
    • 한국콘텐츠학회논문지
    • /
    • 제10권9호
    • /
    • pp.309-317
    • /
    • 2010
  • 치과 교정치료를 위하여 스테인리스 선재가 널리 사용되고 있다. 그러나 내식성이 우수한 스테인리스강 선재가 복합적인 구강환경에서 부식되어 구강조직에 과민반응 또는 이상반응이 발생되고 있다. 이러한 문제를 보완하기 위하여 본 연구에서는 초내식성의 듀플렉스 스테인리스 선재를 교정용 선재로 제시하고 자 한다. DSS선재의 교정용 선재로 제시하기 위하여 기계적 강도와 생물학적 안정성을 평가하였다. 기계적 강도는 상용 교정용 SS선재와 6종의 열처리(실온($28^{\circ}C$), $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, $800^{\circ}C$, $900^{\circ}C$)를 실시한 DSS선재를 이용하여 인장강도시험을 실시하였다. 그리고 최적의 강도를 가지는 열처리 조건에서 제작된 DSS선재를 이용하여 굽힘 모멘트 시험을 실시하여 최대 응력과 탄성계수를 산출하였다. 그리고 생물학적 안정성 평가를 위하여 세포성장률 시험을 실시하였다. 선재를 이용하여 금속용출배지를 만들어 세포를 배양 후 세포성장률을 관찰하였다. 기계적 강도 평가 결과 SS선재($8.17\times10^4\;N/mm^2$)와 DSS500($8.05\times10^4\;N/mm^2$)선재가 유사한 기계적 강도를 가졌다(p=0.05). 생물학적 안전성 평가 결과 세포 독성이 없는 것으로 나타났다(p=0.05). 따라서 본 연구에 제시한 초내식성의 듀플렉스 스테인리스 선재가 교정용 선재로 사용이 가능한 것으로 판단된다.

시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구 (A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA)

  • 곽춘;김진범;손우성
    • 대한치과교정학회지
    • /
    • 제23권2호
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

납착 방법에 따른 교정용 와이어의 기계적 특성 비교 (A Comparative Evaluation of Mechanical Properties of Orthodontic Wire Joints according to Soldering Methods)

  • 이혜진;홍민호
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the tensile strength and mechanical properties of orthodontic wire joints made by gas soldering and laser welding, with and without filling material, to identify the effectiveness and potential clinical application of laser welded orthodontic wires. Methods: Three joint configurations of orthodontic wire were used: diameter 0.9 to 0.9 mm wire, diameter 0.9 to 0.5 wire and diameter 0.9 mm wire to band. The joints were made using three different methods: gas soldering, laser welding with and without filling material. For each kind of joint configuration or connecting method 7 specimens were carefully produced. The tensile strengths were measured with a universal testing machine (Zwick/Roell, Instron, USA). The hardness measurements were carried out with a hardness tester(Future-Tech Co. Tokyo, Japan). Data were analyzed by AVOVA(p= .05) and Turkey HD test(p= .05). Results: In all cases, gas soldering joints were ruptured on a low level on tensile bonding strength. Significant differences between laser welding and gas soldering(p< .05) were found in each joint configuration. The highest tensile strength means were observed for laser welding, with filling material, of 0.9 to 0.9 mm wire joint. Conclusion: In conclusion, the elastic modulus and tensile strength means of laser soldering with filling material were the highest, and the tensile strength means of laser soldering were higher than those of gas soldering.

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

고정성 교정장치를 이용한 치아이동시 발생되는 마찰력 (FRICTIONAL FORCES IN THE FIXED ORTHODONTIC APPLIANCE DURING TOOTH MOVEMENT)

  • 조명숙;김종철
    • 대한치과교정학회지
    • /
    • 제20권2호
    • /
    • pp.409-417
    • /
    • 1990
  • Tooth movement would be impeded by frictional force arised between archwire and tube, bracket or elastics in the fixed orthodontic appliances, which could be changed variably by such several factors as the contact area, normal (perpendicular) force and the condition of contact surface. There were many literatures about frictional force in the orthodontic region, but different results were obtained from little controlled research so that was very difficult in clinical application. Therefore we have reviewed comprehensively previous literatures about frictional force and thus several results were obtained as follows: 1. For use species of the orthodontic wire, frictional force was influenced mainly by surface roughness of wire in the absence of binding, while that was influenced mainly by normal force in high binding angulation. 2. For the cross-section and diameter of the wire, the contact area influenced mainly on frictional force in the absence of binding, while wire stiffness influenced mainly on frictional force in high binding angulation. 3. The greater the bracket width, the greater frictional force, and frictional force of the plastic bracket was larger than that of the metal bracket. 4. For ligation type, frictional force of the stainless steel ligation was larger than that of the elastic ligation, and frictional force was directly proportional to ligation force. 5. Variable frictional force were occured from the saliva combined with such another factors as normal force and mode of surface oxide et al.

  • PDF

유한요소법을 이용한 설측 치아교정시 전치부 후방견인에 관한 연구 (Study on the Retraction of Anterior Teeth for the Lingual Orthodontics with the Three-Dimensional Finite Element Method)

  • 송정한;허훈;박현상
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1237-1244
    • /
    • 2004
  • The orthodontic surgery including lingual orthodontics has recently attracted a person's attention due to its functional and esthetic appreciation. The skeletal anchorage with the miniscrew is newly adopted in the lingual orthodontics to assist the upholding ability. The appliciation needs to understand the mechanism of the orthodontic appliance and its related orthodontic correction for optimal orthodontic treatment. There is, however, few information about the qualitative and quantitative effect of the orthodontic appliance with the miniscrew has not been well identified. In this paper, three dimensional finite element analysis is introduced to the lingual orthodontics in order to investigate the effect of the anterior retraction force on the miniscrew and transpalatal arch wire. The analysis determines the adequate location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results demonstrate the effect of the position of the miniscrew and the transpalatal arch wire on the lingual orthodontics.

전기도금한 교정용 스테인레스스틸 선재의 세포독성에 관한 연구 (Evaluation of cytotoxicity of electroplated stainless steel orthodontic wire)

  • 이계형;조진형;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제35권2호
    • /
    • pp.127-136
    • /
    • 2005
  • 광도 차이를 보이지 않았지만 전기도금한 선재 (p<0.001). 스테인레스스틸 선재 (p <0.05). 구리 (p<0.001) 는 배지만을 첨가한 경우보다 통계적으로 유의한 흡광도 감소를 보였다 ISO 10993, part 5에 따라 구리는 "강한 독성"을 보이는 반면 티타늄과 스테인레스스틸 선재는 "무독성". 그리고 전기도금 선재는 "중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.

교정력에 관한 임상적인 소고 (A Clinical Consideration of Orthodontic Force)

  • 김일봉;구옥경;성재현;김영수
    • 대한치과의사협회지
    • /
    • 제11권2호
    • /
    • pp.123-129
    • /
    • 1973
  • The authors measured orthodontic force using the orthodontic materials of the Rocky Mountain Products Company. The results were as follows : ① Use latex of wide diameter in long distance, and when the latex of wide diameter activated by four or five times, we obtained a optimal force. ② The authors obtained canine retractions with sectional arch. Activation of sectional arch began at 1mm and had to do not activations of 3mm more. ③ The leveling started from .014 green round wire and finished to. 0.16" green Elgiloy round wire. Permit only a mild force in ideal arch form, in rectangular wire. ④ Fundamentaly, elastic thread obtained maximum force by activating as two times. ⑤ Coil spring obtained more heavy force from short distance than long distance.

  • PDF