• Title/Summary/Keyword: Orthopaedics

Search Result 181, Processing Time 0.027 seconds

Finite Element Analysis of the Artery and PTFE End-To-Side Anastomosis with 45${\circ}$ Anastomotic angle (45${\circ}$ 문합각을 가진 동맥과 PTFE 단측 문합의 유한요소해석)

  • Han, Geun-Jo;Kim, Hyeong-Tae;An, Seong-Chan;Sin, Jeong-Uk;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.253-259
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the anastomosis of an artery with length of 20mm(z direction, along the horizental artery), inner diameter of 4mm, thickness fo 0.5mm and a PTFE graft with length of 5.7mm, inner diameter of 2mm, thickness of 0.2mm when anastomotic angle was $45^{\circ}$ and inner pressure of 1330 dyne/mm2 was applied inside the 2 conduits. From the analysis results were obtained as follows. (1) Artery diameter increased in both horizontal x(along the length of artery) and vertical y(perpendicular to the length of artery)directions and the magnitude of that in x direction was bigger than that in y direction. (2) The compliance was maximum on the anastomosis, especially on that with acute angle. The reduction of compliance was observed from the anastomosis area to the either right or left end. (3) The equivalent stress was maximum on top in the y direction and minimum on the nodes apart $110^{\circ}$ in circumferential direction from the top. (4) The equivalent stress was maximum in t도 vicinity of anastomosis with acute angle along the longitudinal direction of the artery. This trend was also observed along the PTFE graft.

  • PDF

The Primary Reverse Total Shoulder Arthroplasty for Post-septic Destroyed Shoulder - A Case Report - (감염 후 손상된 견관절에 선택된 일차적 역구형 견관절 대치술 - 1 례 보고 -)

  • Moon, Young-Lae;Nam, Ki-Young;Jo, Sueng-Hwan;Venkat, Gorthi
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.232-235
    • /
    • 2009
  • Purpose: We report here on a solution for the case of a 71 year old lady with cartilage destruction in the left shoulder and the loss of the rotator cuff secondary to post-septic arthritic sequelae. Materials and methods: After thorough laboratory, clinical and radiological investigation of the patient to rule out any foci of active infection, we contemplated performing reverse total shoulder arthroplasty as a primary procedure. Results: At 22 months follow up, the patient had an excellent result according to the UCLA and ASES scales. Conclusion: Reverse total shoulder arthroplasty seems to be an efficient procedure to improve pain and function in the post-septic shoulder accompanying severe rotator cuff injury.

Arthroscopic Bankart Repair for Post-seizure Anterior Instabilities of Shoulder - 2 Cases Report - (전간 발작과 관련된 견관절 전방 불안정성 환자에서 시행한 관절경적 Bankart봉합술 - 2예 보고 -)

  • Moon, Young-Lae;Yang, Hun;Gorthi, Venkat
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.98-101
    • /
    • 2009
  • Purpose: These case reports have been prepared to highlight the uncommon occurrence of anterior shoulder dislocation after an epileptic seizure, the recognition of which is important as this type of injury is associated with bony lesions and a high incidence of recurrence. Materials and Methods: We report two cases of recurrent anterior dislocation of the shoulder due to grand mal epilepsy. These cases were treated as usual anterior dislocations of the shoulder, and were regularly followed to detect any recurrence of shoulder instability. Results: Outcome of the surgery in the two cases was different because of the differences in seizure control. In the patient in whom seizures were well-controlled, there was no recurrence of instability, while the patient with poorly controlled seizures developed a recurrence of the dislocation following shoulder repair. Conclusion: The authors emphasize the need to control seizures in order to prevent injury recurrence in this subset of patients.

Blood Flow Changes by Anastomotic Method in Fontan Operation (폰탄 수술에서 문합방법에 따른 혈류 변화)

  • Kim, S.H.;Park, Y.H.;Cho, B.K.;Kim, J.H.;Hong, Y.S.;Kim, Y.H.;Kim, S.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.203-206
    • /
    • 1996
  • To understand the local fluid dynamics for different desists of Fontan operation, five models were made out of Pyrex glass to facilitate in-vitro study. Model I, II and III have same position of the center of the anastomosis of the IVC( inferior vena cava) with that of the SVC(superior vena cava), but Model IV and V have 10 mm offset between them. Also the anastomotic junction angles are different(Model I and $IV:90^{\circ}$, Model II and $V:70^{\circ}$, Model $III:45^{\circ}$). These models were then connected to a flow loop for flow visualization study. In Model I any dominant vortex was not seen in the central region of the juntion, but a large unstable vortex was created in the Model II and III. In Model IV and V a significant stagnation region was created in the middle of the offset region. It also showed that the flow direction from the IVC and SVC to the LPA(left pulmonary artery) and RPA(right pulmonary artery) highly depends on the offset of the junction rather than the anastomotic junction angle.

  • PDF

Elution of amikacin and vancomycin from a calcium sulfate/chitosan bone scaffold

  • Doty, Heather A.;Courtney, Harry S.;Jennings, Jessica A.;Haggard, Warren O.;Bumgardner, Joel D.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.3
    • /
    • pp.159-172
    • /
    • 2015
  • Treatment of polymicrobial infected musculoskeletal defects continues to be a challenge in orthopaedics. This research investigated single and dual-delivery of two antibiotics, vancomycin and amikacin, targeting different classes of microorganism from a biodegradable calcium sulfate-chitosan-nHA microsphere composite scaffold. The addition of chitosan-nHA was included to provide additional structure for cellular attachment and as a secondary drug-loading device. All scaffolds exhibited an initial burst of antibiotics, but groups containing chitosan reduced the burst for amikacin at 1hr by 50%, and vancomycin by 14-25% over the first 2 days. Extended elution was present in groups containing chitosan; amikacin was above MIC ($2-4{\mu}g/mL$, Pseudomonas aeruginosa) for 7-42 days and vancomycin was above MIC ($0.5-1{\mu}g/mL$ Staphylococcus aureus) for 42 days. The antibiotic activity of the eluates was tested against S. aureus and P. aeruginosa. The elution from the dual-loaded scaffold was most effective against S. aureus (bacteriostatic 34 days and bactericidal 27 days), compared to vancomycin-loaded scaffolds (bacteriostatic and bactericidal 14 days). The dual- and amikacin-loaded scaffolds were effective against P. aeruginosa, but eluates exhibited very short antibacterial properties; only 24 hours bacteriostatic and 1-5 hours bactericidal activity. For all groups, vancomycin recovery was near 100% whereas the amikacin recovery was 41%. In conclusion, in the presence of chitosan-nHA microspheres, the dual-antibiotic loaded scaffold was able to sustain an extended vancomycin elution longer than individually loaded scaffolds. The composite scaffold shows promise as a dual-drug delivery system for infected orthopaedic wounds and overcomes some deficits of other dual-delivery systems by extending the antibiotic release.

Anterior Cervical Discectomy and Fusion YouTube Videos as a Source of Patient Education

  • Ovenden, Christopher Dillon;Brooks, Francis Michael
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.987-991
    • /
    • 2018
  • Study Design: Cross sectional study. Purpose: To assess the quality of anterior cervical discectomy and fusion (ACDF) videos available on YouTube and identify factors associated with video quality. Overview of Literature: Patients commonly use the internet as a source of information regarding their surgeries. However, there is currently limited information regarding the quality of online videos about ACDF. Methods: A search was performed on YouTube using the phrase 'anterior cervical discectomy and fusion.' The Journal of the American Medical Association (JAMA), DISCERN, and Health on the Net (HON) systems were used to rate the first 50 videos obtained. Information about each video was collected, including number of views, duration since the video was posted, percentage positivity (defined as number of likes the video received, divided by the total number of likes or dislikes of that video), number of comments, and the author of the video. Relationships between video quality and these factors were investigated. Results: The average number of views for each video was 96,239. The most common videos were those published by surgeons and those containing patient testimonies. Overall, the video quality was poor, with mean scores of 1.78/5 using the DISCERN criteria, 1.63/4 using the JAMA criteria, and 1.96/8 using the HON criteria. Surgeon authors' videos scored higher than patient testimony videos when reviewed using the HON or JAMA systems. However, no other factors were found to be associated with video quality. Conclusions: The quality of ACDF videos on YouTube is low, with the majority of videos produced by unreliable sources. Therefore, these YouTube videos should not be recommended as patient education tools for ACDF.

Does Second-Generation Suspensory Implant Negate Tunnel Widening of First-Generation Implant Following Anterior Cruciate Ligament Reconstruction?

  • Sundararajan, Silvampatti Ramasamy;Sambandam, Balaji;Singh, Ajay;Rajagopalakrishnan, Ramakanth;Rajasekaran, Shanmuganathan
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.341-347
    • /
    • 2018
  • Purpose: Tunnel widening following anterior cruciate ligament (ACL) reconstruction is commonly observed. Graft micromotion is an important contributing factor. Unlike fixed-loop devices that require a turning space, adjustable-loop devices fit the graft snugly in the tunnel. The purpose of this study is to compare tunnel widening between these devices. Our hypothesis is that the adjustable-loop device will create lesser tunnel widening. Materials and Methods: Ninety-eight patients underwent ACL reconstruction from January 2013 to December 2014. An adjustable-loop device was used in 54 patients (group 1) and a fixed-loop device was used in 44 patients (group 2). Maximum tunnel widening at 1 year was measured by the L'Insalata's method. Functional outcome was measured at 2-year follow-up. Results: The mean widening was 4.37 mm (standard deviation [SD], 2.01) in group 1 and 4.09 mm (SD, 1.98) in group 2 (p=0.511). The average International Knee Documentation Committee score was 78.40 (SD, 9.99) in group 1 and 77.11 (SD, 12.31) in group 2 (p=0.563). The average Tegner-Lysholm score was 87.25 (SD, 3.97) in group 1 and 87.29 in group 2 (SD, 4.36) (p=0.987). There was no significant difference in tunnel widening and functional outcome between the groups. Conclusions: The adjustable-loop device did not decrease the amount of tunnel widening when compared to the fixed-loop device. There was no significant difference in outcome between the two fixation devices. Level of Evidence: Level 3, Retrospective Cohort.

Is treatment with platelet-rich fibrin better than zinc oxide eugenol in cases of established dry socket for controlling pain, reducing inflammation, and improving wound healing?

  • Paul, Sam;Choudhury, Rupshikha;Kumari, Nandini;Rastogi, Sanjay;Sharma, Ashish;Singh, Vikas;Laskar, Shyamalendu;Dubey, Tushar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Objectives: To appraise the effectiveness of platelet-rich fibrin (PRF) in the management of established dry socket in terms of pain, inflammation, and wound healing. Materials and Methods: Two hundred patients with established alveolar osteitis were studied to determine the efficacy of PRF and zinc oxide eugenol (ZOE) for pain control, inflammation reduction, and wound healing. Patients were randomly allocated to Group A (PRF) or Group B (ZOE). Patients were examined on the 1st, 3rd, 7th, and 14th postoperative day and evaluated for pain using visual analogue scale scores, inflammation with a gingival index score, and wound healing through a determination of the number of bony walls exposed. Results: Group A showed better results in terms of pain remission, control of inflammation, and wound healing compared to Group B. Results between groups were statistically significant (P<0.05). Conclusion: PRF is a better alternative than ZOE for the effective management of alveolar osteitis.

Specific urinary metabolites in canine mammary gland tumors

  • Valko-Rokytovska, Marcela;Ocenas, Peter;Salayova, Aneta;Titkova, Radka;Kostecka, Zuzana
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.23.1-23.10
    • /
    • 2020
  • The identification of biomarkers that distinguish diseased from healthy individuals is of great interest in human and veterinary fields. In this research area, a metabolomic approach and its related statistical analyses can be useful for biomarker determination and allow non-invasive discrimination of healthy volunteers from breast cancer patients. In this study, we focused on the most common canine neoplasm, mammary gland tumor, and herein, we describe a simple method using ultra-high-performance liquid chromatography to determine the levels of tyrosine and its metabolites (epinephrine, 3,4-dihydroxy-L-phenylalanine, 3,4-dihydroxyphenylacetic acid, and vanillylmandelic acid), tryptophan and its metabolites (5-hydroxyindolacetic acid, indoxyl sulfate, serotonin, and kynurenic acid) in canine mammary cancer urine samples. Our results indicated significantly increased concentrations of three tryptophan metabolites, 5-hydroxyindolacetic acid (p < 0.001), serotonin, indoxyl sulfate (p < 0.01), and kynurenic acid (p < 0.05), and 2 tyrosine metabolites, 3,4-dihydroxy-L-phenylalanine (p < 0.001), and epinephrine (p < 0.05) in urine samples from the mammary gland tumor group compared to concentrations in urine samples from the healthy group. The results indicate that select urinary tyrosine and tryptophan metabolites may be useful as non-invasive diagnostic markers as well as in developing a therapeutic strategy for canine mammary gland tumors.

Clinical and radiologic study of total knee replacement arthroplasty using Doujet GF bone cement (liquid-powder bone cement containing gentamicin) (Doujet GF 골 시멘트를 사용한 인공 슬관절치환술의 임상적, 방사선적 고찰)

  • Sungwook Choi;Seong-meen Yoon;Joseph Y. Rho;In-seok Son
    • Journal of Medicine and Life Science
    • /
    • v.20 no.2
    • /
    • pp.60-66
    • /
    • 2023
  • Gentamicin-loaded bone cement used in total joint arthroplasty is indispensable, as it provides stability by directly binding the surfaces of implants and bones. Depending on multiple factors, including the material of the bone cement used, common complications, such as aseptic loosening, osteolysis, and infection can occur postoperatively. In clinical practice, Doujet bone cement is easy to handle (pre-packed all-in-one system), and has shown low failure rates and non-inferior results compared with similar available products. We conducted a retrospective comparative study to analyze the clinical and radiological results of each bone cement group to establish the safety and usefulness of Doujet bone cement. From July 2020 to July 2022, we enrolled 198 patients in this study after an average follow-up period of 37 months (range, 6-48 months). In 99 patents, Doujet® bone cement (Injecta, Gunpo, Korea) was used for total knee arthroplasty (TKA), while Refobacin® bone cement (Biomet, Warsaw, IN, USA) was used in 99 patients. The average range of motion (ROM) of the knee increased by 2.4° (from 127.0° preoperatively to 129.4° postoperatively) in the Doujet group, and by 0.1° (from 128.7° to 128.8°) in the Refobacin group (P=0.701). The Western Ontario and McMaster Universities (WOMAC) osteoarthritis index scores decreased from 44.1 to 7.8 in the Doujet group, and from 44.2 to 6.3 in the Refobacin group (P=0.162). Complications, such as osteolysis or post-operative wound infection, did not occur in more than two cases in both groups. The WOMAC and ROM of the knee in both groups had no clinical differences. Both Doujet and Refobacin similarly showed low complication rates after TKA.