• Title/Summary/Keyword: Outer surface

Search Result 1,383, Processing Time 0.027 seconds

The Effect of the Thermal Conductivity of a Tube and the Convective Heat Transfer on the Outer Surface of a Tube on the Energy Separation in Vortex Tubes (튜브의 열전도도와 튜브 외면에서의 대류열전달이 보텍스튜브의 에너지 분리에 미치는 영향)

  • 유갑중;이병화;최병철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.845-852
    • /
    • 2001
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the effects of the conductivity of a tube and convective heat transfer on the outer surface of a tube. The experiment was carried out with different conductivity (pyrex, stainless steel and copper) of a tube and three kinds of convective heat transfer modes (adiabatic condition, natural convection (air) and forced convection (water) on the outer surface of a tube. the results were obtained that hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the forced convection of water. However, the cold exit temperature was little affected by heat transfer modes on the outer surface in vortex tubes.

  • PDF

Influence of Wavy Surface on the Turbulence in the Outer Layer (파형 벽면이 외층의 난류량에 미치는 영향에 대한 고찰)

  • Na, Yang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1053-1059
    • /
    • 2001
  • Results from direct numerical simulation and LDV measurements are analyzed to investigate the influence of structured surface on turbulence in the outer layer. To provide a well-defined surface roughness, sinusoidal wavy surface was used. Even though flows over smooth and wavy surface show very different process for maintaining turbulence in the vicinity of the wall, there are some evidences that the turbulence in the outer layer has a universal characteristics and it may be possible to give a speculative interpretation that similarity of turbulent structures arises because Reynolds stress producing motion is similar regardless of different turbulence generation mechanisms embedded in both cases.

Analysis of Thermal Stress and Fatigue Life in the Steel Shell of a Cupola Furnace (큐폴라 용해로 철피의 열응력 및 피로수명 해석)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.47-54
    • /
    • 2020
  • Themo-mechanical analysis was carried out using the finite element method for the steel shell of a cupola furnace. When the outer surface of the shell was cooled with water to within the temperature range of 35-80 ℃ during operation of the cupola, the inner surface of the shell was expected to exhibit a temperature of 65-248 ℃ based on heat transfer analysis. The shell was also expected to have an equivalent stress range of 100-280 MPa in the outer surface over the temperature range examined. Upon cooling the shell to obtain an outer surface temperature <80 ℃, the maximum equivalent stress of the shell did not exceed the yield strength. Although the temperature of the outer surface varied between 35 and 80 ℃ periodically due to the cooling control problem, the fatigue stress at the outer surface of the shell was calculated to be within the fatigue strength. During a non-operational period to examine the system between furnace operations, the thermal stress presented in the shell was sufficiently low to reach the desired yield strength and fatigue limit.

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

EFFECTS OF ANGULAR VELOCITY AND BOUNDARY TEMPERATURE TO THERMO-ELASTIC CHARACTERISTICS ON HOMOGENEOUS CIRCULAR DISKS SUBJECTING TO CONTACT FORCES

  • GO, JAEGWI
    • Journal of applied mathematics & informatics
    • /
    • v.39 no.1_2
    • /
    • pp.31-43
    • /
    • 2021
  • A homogeneous circular disk undergoing a contact force is considered to investigate the thermo-elastic characteristics, and the inquiry is based on the variations of outer surface temperature and angular velocity. The intensity of stresses grows with the increase of outer surface temperature, and the circumferential strain reacts more sensitively to the change of outer surface temperature than the radial strain. In general, higher angular velocity produces; (i) larger expansion in the radial direction, (ii) smaller displacement in the circumferential, (iii) diminished intensity in the stresses. It is demonstrated that outer surface temperature and angular velocity are critical factors in the determination of thermo-elastic characteristics of homogeneous circular disks subjecting to a contact force. The results obtained can be applied on the design of a homogeneous circular cutter to promote proper and reliable thermos-elastic characteristics in service by the proper operation of these parameters.

AN IMMUNOHISTOCHEMICAL STUDY OF THE DISTRIBUTION OF FIBRONECTIN, LAMININ AND TENASCIN IN THE REGENERATING PERIODONTAL TISSUE (재생중인 치주조직내 Fibronectin, Laminin 및 Tensacin의 분포에 관한 면역조직화학적 연구)

  • Chung, Gap-Hwan;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.321-340
    • /
    • 1995
  • The regeneration of destructed periodontal tissues is one of the ultimate objectives of periodontal therapy. Guided tissue regeneration technique was developed for the ideal regeneration of periodontal tissues. In order to investigate the role of fibronectin, laminin and tenascin in the regenerating process of periodontal tissues, the expanded PTFE barrier membranes(Gore Associates, USA) removed from the patients who had been treated by guided tissue regeneration(GTR) and guided bone regeneration(GBR) techniques were fixed in neutral formalin for 6-24 hours, embedded with paraffin, sectioned at $4-6{\mu}m$ in thickness, and immunohistochemically processed by Avidin-Biotin peroxidase complex method for detecting fibronectin, laminin and tenascin. Monoclonal mouse anti-human fibronectin antibody(Oncogene Science, USA., 1:100), monoclonal mouse anti-human laminin antibody(Oncogene Science, USA., 1:50) and mouse anti-human tenascin antibody(Oncogene Science, USA, 1:10) were used as primary antibodies. The light microscopic findings were as follows: (1) The distribution of fibronectin, laminin and tenascin was various according to the area of barrier membranes. (2) The distribution of fibronectin in case of GBR was extensive in the tissue on the outer surface of barrier membranes, and rare in the intervening space and on the inner surface. In case of GTR it was extensive on the outer surface and in the intervening space, and rare on the inner surface. (3) The distribution of laminin was rare in the tissue on the outer, the inner surface and intervening space of barrier membranes, regardless of GBR or GTR. (4) In case 'of GBR rare distribution of tenascin was observed on the outer surface only, except the inner surface and the intervening space of barrier membranes. In case of GTR the distribution of tenascin was extensive in the tissue on the outer surface, rare in intervening space and the inner surface. The results suggest that fibronectin, laminin and tenascin may play a important role in the regenerating process of periodontal tissue, and they may affect the outcome of healing.

  • PDF

Measurement and Analysis of the Section Profile for Feature Line Surface on an Automotive Outer Panel (자동차 외판 특징선 곡면의 단면 형상 측정과 분석)

  • Choe, W.C.;Chung, Y.C.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The current study presents a geometric measurement and analysis of the section profile for a feature line surface on an automotive outer panel. A feature line surface is the geometry which is a visually noticeable creased line on a smooth panel. In the current study the section profile of a feature line surface is analyzed geometrically. The section profile on the real press panel was measured using a coordinate measuring machine. The section profiles from the CAD model and the real panel are aligned using the same coordinate system defined by two holes near the feature line. In the aligned section profiles the chord length and height of the curved part were measured and analyzed. The results show that the feature line surface on the real panel is doubled in width size.

An Experimental Study on the Thermal Performance of a Concentric Annular Heat Pipe

  • Boo Joon Hong;Park Soo Yong;Kim Do Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1036-1043
    • /
    • 2005
  • Concentric annular heat pipes (CAHP) were fabricated and tested to investigate their thermal characteristics. The CAHPs were 25.4 mm in outer diameter and 200 mm in length. The inner surface of the heat pipes was covered with screen mesh wicks and they were connected by four bridge wicks to provide liquid return path. Three different heat pipes were fabricated to observe the effect of change in diameter ratios between 2.31 and 4.23 while using the same outer tube dimensions. The major concern of this study was the transient response as well as isothermal characteristics of the heat pipe outer surface, considering the application as uniform heating device. A better performance was achieved as the diameter ratio increased. For the thermal load of 180 W, the maximum temperature difference on the outer surface in the axial direction of CAHP was $2.3^{\circ}C$ while that of the copper block of the same outer dimension was $5.9^{\circ}C.$ The minimum thermal resistance of the CAHP was measured to be $0.004^{\circ}C/W.$ In regard to the transient response during start-up, the heat pipe showed almost no time lag to the heat source, while the copper block of the same outer dimensions exhibited about 25 min time lag.

Differential Effects of Local Anesthetics on Rate of Rotational Mobility between Hydrocarbon Interior and Surface Region of Model Membrane Outer Monolayer

  • Chung, In-Kyo;Cha, Seong-Kweon;Chung, Yong-Za;Kim, Bong-Sun;Choi, Chang-Hwa;Cho, Goon-Jae;Jang, Hye-Ock;Yun, Il
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.1
    • /
    • pp.41-46
    • /
    • 2000
  • Using fluorescence polarization of 12-(9-anthroyloxy)stearic acid (12-AS) and 2-(9-anthroyloxy)stearic acid (2-AS), we evaluated the differential effects of local anesthetics on differential rotational rate between the surface (in carbon number 2 and its surroundings including the head group) and the hydrocarbon interior (in carbon number 12 and its surroundings) of the outer monolayer of the total lipid fraction liposome extracted from synaptosomal plasma membrane vesicles. The anisotropy (r) values for the hydrocarbon interior and the surface region of the liposome outer monolayer were $0.078{\pm}0.001$ and $0.114{\pm}0.001,$ respectively. This means that the rate of rotational mobility in the hydrocarbon interior is faster than that of the surface region. In a dose-dependent manner, the local anesthetics decreased the anisotropy of 12-AS in the hydrocarbon interior of the liposome outer monolayer but increased the anisotropy of 2-AS in the surface region of the monolayer. These results indicate that local anesthetics have significant disordering effects on the hydrocarbon interior but have significant ordering effects on the surface region of the liposome outer monolayer.

  • PDF

Torsional Elastic Waves Propagating in a Cylinder with a Periodically Corrugated Outer Surface (주기적으로 울퉁불퉁한 실린더에서 전파하는 비틂 탄성파)

  • Kim Jin Oh
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.303-306
    • /
    • 1999
  • The paper describes a theoretical study on the speed of the torsional elastic waves propagating in a circular cylinder whose outer radius varies periodically as a harmonic function of the axial coordinate. The approximate solution for the phase speed has been obtained using the perturbation technique for sinusoidal modulation of small amplitude. It is shown that the wave speed in the cylinder with a corrugated outer surface is less than that in a smooth cylinder by the square of the amplitude of the surface perturbation. This theoretical prediction agrees reasonably with an experimental observation reported earlier. It is also shown that the wave speed reduction due to the surface corrugation becomes larger for a thinner cylinder and for a bigger density of corrugation.

  • PDF