Design-Oriented Stability of Outer Voltage Loop in Capacitor Current Controlled Buck Converters

  • Zhang, Xi;Zhang, Zhongwei;Bao, Bocheng;Bao, Han;Wu, Zhimin;Yao, Kaiwen;Wu, Jing
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.869-880
    • /
    • 2019
  • Due to the inherent feedforward of load current, capacitor current (CC) control shows a fast transient response that makes it suitable for the power supplies used in various portable electronic devices. However, considering the effect of the outer voltage loop, the stable range of the duty-cycle is significantly diminished in CC controlled buck converters. To investigate the stability effect of the outer voltage loop on buck converters, a CC controlled buck converter with a proportion-integral (PI) compensator is taken as an example, and its second-order discrete-time model is established. Based on this model, the instability caused by the duty-cycle is discussed with consideration of the outer voltage loop. Then the dynamical effects of the feedback gain of the PI compensator and the equivalent series resistance (ESR) of the output capacitor on the CC controlled buck converter with a PI compensator are studied. Furthermore, the design-oriented closed-loop stability criterion is derived. Finally, PSIM simulations and experimental results are supplied to verify the theoretical analyses.

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

Closed-loop Identification and Controller Design for a Converter (컨버터의 폐루프 식별 및 제어기 설계)

  • Yun, Kyong-Han;Lim, Yeon-Soo;Jin, Li-Hua;Kim, Jae-Jin;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1632-1633
    • /
    • 2007
  • This paper presents a new method of designing digital controller based on closed-loop identification of a pulse width modulation (PWM) converter system. We consider the control system structure which is composed of both current control loop and voltage control loop. The current controller can be designed independently of voltage loop. Whereas voltage controller can not do easily due to the PWM switching component which is nonlinear in nature. Furthermore, the control objective of inner loop is to track the sine wave of 60 Hz, but the outer loop shall maintain the constant DC voltage irrespective to load change. To systematically design outer loop controller, we propose a method finding linear approximate model of the nonlinear inner loop part including current controller by closed loop identification. Based on the identified model, we show that a simple digital voltage controller can be directly designed and it has good performance.

  • PDF

Small-Signal Modeling and Analysis of Input Series-Output Parallel Connected Converter System for High Voltage Power Conversion Application (고 입력 전압 응용에 적합한 입력직렬-출력병렬 컨버터 시스템의 소신호 분석)

  • You, Jeong-Sik;Kim, Jung-Won;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2712-2714
    • /
    • 1999
  • The small signal model for input series-output parallel connected converter system employing charge control together with input capacitor voltage feedback loop is developed. From the model developed, the effect of input capacitor voltage feedback loop to the system stability and outer loop compensator design is analyzed. Theoretical results and simulation show that input capacitor voltage feedback loop has no critical effects on the system stability, so the system can be reduced to a equivalent single module for the stability analysis and outer loop compensator design.

  • PDF

PWM-VSI controller of Three-phase UPS Using Stationary Reference Frame (정지좌표계를 이용한 3상 UPS용 PWM-VSI 제어)

  • Kim M.K.;Kim J.S.;Bang S.S.;Choi J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.965-968
    • /
    • 2003
  • This paper describes the PWM-VSI controller of three-phase UPS system using stationary reference frame. This controller meets the specification the UPS inverter output voltage even under the unbalanced or nonlinear load. This controller is also constructed with duble control loop of the outer voltage control loop and the inner current control loop. For the fast response of the output voltage control, yhr inner current control loop of the capacitor current os used. To get the good property against overshoot, the If controller us used. The outer voltage controller is designed with P controller and the high gain transfer function is used for the zero steady state error. All control gains of both controller is designed base on the CDM method.

  • PDF

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Design of Single Loop Output Voltage Controller for 3 Phase PWM Inverterl (3상 PWM 인버터의 단일루프 전압제어기 설계)

  • 곽철훈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.561-568
    • /
    • 2003
  • There arc two ways in the output voltage control method in PWM inverters. One Is double loop voltage control composed of inner current control loop and outer voltage control loop.'rho other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. However, in case of low output impedance, it shows good control performance in all load ranges than double loop voltage control. In this paper, the rule and the gain of single loop voltage control have been developed analytically and these were verified through computer simulation and experiment.

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.