• 제목/요약/키워드: Over coupling

검색결과 399건 처리시간 0.025초

An Evaluation of the Coupling Coordination Degree of the Yangtze River Delta Port Cluster Based on Coupling Theory

  • Lu Ke;Yong-Sik Oh
    • 한국항해항만학회지
    • /
    • 제48권2호
    • /
    • pp.78-87
    • /
    • 2024
  • To quantitatively assess the correlation between subsystems within a port cluster and the overall coordinated development of the port group, the current paper evaluates the coordinated development of port clusters. First, we construct an evaluation index system for the coupling and coordination of port clusters. Next, we introduce the contribution index of port subsystems, coupling degree, and coupling coordination degree functions to formulate a coupling coordination evaluation model for the port cluster. Finally, we use the Yangtze River Delta port cluster as a case study for validation, specifically using empirical data from 2012 to 2021. The findings reveal distinct phased characteristics in the coupling and coordination of port clusters in the Yangtze River Delta, marked by a notable transition from "maladjustment" to "coordination." Further, sustained high coupling values over a decade indicate a significant level of competition and cooperation among ports within the Yangtze River Delta port cluster. Over time, this competitive and collaborative dynamic has progressively evolved toward a more positive and structured direction. Lastly, it is expected that the evaluation model proposed in this paper can be extrapolated to other port clusters to gauge the extent of coordinated development, thereby facilitating horizontal comparisons and vertical analyses.

벽식 아파트 구조에서 연결부재의 거동특성을 고려한 비선형 동적 응답 (Nonlinear Dynamic Response of Well-Slab Apartment Building Considering The Behavior of Coupling Elements)

  • 김기현;장극관;서대원;천영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.437-442
    • /
    • 2002
  • The purpose of this study is to investigate nonlinear behavior and estimate ultimate resistance of the wall structure against seismic loading. Experimental data for RC coupling elements are used for specifying the strength deterioration and stiffness degradation factor of hysteretic model. Modified coupling element models are used in the push over analysis and time history analysis. In the time history analysis, three earthquake waves are used in the analysis and their peak ground accelerations are changed to be 0.2g. The conclusions of this study are as follows : (1) In the push over analysis, yielding of coupling elements occurred at lower story with small story drift ratio as 0.3%. (2) In the time history analysis, the story drift ratio is sufficient for the requirement of Korean Code, But coupling elements at most stories of the buildings occurred yielding. i. e. the earthquake resistant capacity of shear wall structures is not sufficient at 0.2g.

  • PDF

Robust Two-Phase Clock Oxide TFT Shift Register over Threshold Voltage Variation and Clock Coupling Noises

  • Nam, Hyoungsik;Song, Eunji
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.321-324
    • /
    • 2014
  • This letter describes a two-phase clock oxide thin-film transistor shift register that executes a robust operation over a wide threshold voltage range and clock coupling noises. The proposed circuit employs an additional Q generation block to avoid the clock coupling noise effects. A SMART-SPICE simulation shows that the stable shift register operation is established for the clock coupling noises and the threshold voltage variation from -4 V to 5 V at a line time of $5{\mu}s$. The magnitude of coupling noises on the Q(15) node and Qb(15) node of the 15th stage is respectively -12.6 dB and -26.1 dB at 100 kHz in the proposed circuit, compared to 6.8 dB and 10.9 dB in a conventional one. In addition, the estimated power consumption is 1.74 mW for the proposed 16-stage shift registers at $V_{TH}=-1.56V$, compared to 11.5 mW for the conventional circuits.

A New Optical Coupling Scheme from Laser Diodes to Single-Mode Fibers for Low Cost Telecommunication Modules

  • Shim, Jong-In;Kweon, Gyeong-il
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.80-82
    • /
    • 1998
  • A new fiber coupling scheme using thermally over-expanded core(TOEC) fiber was proposed and demonstrated. In the coupling experiment between 1.3${\mu}{\textrm}{m}$ FP-LD and the proposed TOEC fiber with a tapered hemispherical microlens. superior performances such as a long working distance, a high coupling efficiency, and large misalignment tolerances were verified experimentally.

플랜지된 평행 평판 도파관으로 급전된 슬릿을 통한 도체 스트립과의 최대 결합 현상 (Maximum Coupling Phenomena through a Slit Fed by a Flanged Parallel-Plate Waveguide with a Conducting Strip)

  • 이종익;조영기
    • 한국전자파학회논문지
    • /
    • 제17권6호
    • /
    • pp.501-510
    • /
    • 2006
  • 본 논문에서는 플랜지된 평행 평판 도파관의 슬릿을 통한 도체 스트립과의 전자기적인 결합을 연구하였다. 슬릿의 전계와 스트립의 유기 전류에 관한 결합 적미분 방정식을 유도하고 모멘트 방법으로 풀었다. 몇 가지 슬릿을 통한 최대 결합 현상들의 특성을 도체 스트립의 위치, 동작 주파수, 스트립의 길이 등 다양한 파라미터에 대한 슬릿의 등가 어드미턴스와 결합 전력의 변화를 통해 조사하였다.

기상청 계절예측시스템(GloSea5)의 해양성층 강화시기 단기 해양예측 정확도 및 대기-해양 접합효과 (Accuracy of Short-Term Ocean Prediction and the Effect of Atmosphere-Ocean Coupling on KMA Global Seasonal Forecast System (GloSea5) During the Development of Ocean Stratification)

  • 정영윤;문일주;장필훈
    • 대기
    • /
    • 제26권4호
    • /
    • pp.599-615
    • /
    • 2016
  • This study investigates the accuracy of short-term ocean predictions during the development of ocean stratification for the Korea Meteorological Administration (KMA) Global Seasonal Forecast System version 5 (GloSea5) as well as the effect of atmosphere-ocean coupling on the predictions through a series of sensitive numerical experiments. Model performance is evaluated using the marine meteorological buoys at seas around the Korean peninsular (KP), Tropical Atmosphere Ocean project (TAO) buoys over the tropical Pacific ocean, and ARGO floats data over the western North Pacific for boreal winter (February) and spring (May). Sensitive experiments are conducted using an ocean-atmosphere coupled model (i.e., GloSea5) and an uncoupled ocean model (Nucleus for European Modelling of the Ocean, NEMO) and their results are compared. The verification results revealed an overall good performance for the SST predictions over the tropical Pacific ocean and near the Korean marginal seas, in which the Root Mean Square Errors (RMSE) were $0.31{\sim}0.45^{\circ}C$ and $0.74{\sim}1.11^{\circ}C$ respectively, except oceanic front regions with large spatial and temporal SST variations (the maximum error reached up to $3^{\circ}C$). The sensitive numerical experiments showed that GloSea5 outperformed NEMO over the tropical Pacific in terms of bias and RMSE analysis, while NEMO outperformed GloSea5 near the KP regions. These results suggest that the atmosphere-ocean coupling substantially influences the short-term ocean forecast over the tropical Pacific, while other factors such as atmospheric forcing and the accuracy of simulated local current are more important than the coupling effect for the KP regions being far from tropics during the development of ocean stratification.

고압 배전선로 전력선 통신 신호결합장치 개발 (Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line)

  • 이재조;박영진;오휘명;김관호;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권6호
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

Effect of two way thermal hydraulic-fuel performance coupling on multicycle depletion

  • Awais Zahur;Muhammad Rizwan Ali;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4431-4446
    • /
    • 2023
  • A Multiphysics coupling framework, MPCORE, has been developed to analyze safety parameters using the best estimate codes. The framework contains neutron kinetics (NK), thermal hydraulics (TH), and fuel performance (FP) codes to analyze fuel burnup, radial power distribution, and coolant temperature (Tbc). Shuffling and rotation capabilities have been verified on the Watts Bar reactor for three cycles. This study focuses on two coupling approaches for TH and FP modules. The one-way coupling approach involves coupling the FP code with the NK code, providing no data to the TH modules but getting Tbc as boundary condition from TH module. The two-way coupling approach exchanges information from FP to TH modules, so that the simplified heat conduction solver of the TH module is not used. The power profile in both approaches does not differ significantly, but there is an impact on coolant and cladding parameters. The one-way coupling approach tends to over-predict the cladding hydrogen concentration (CHC). This research highlights the difference between one-way and two-way coupling on critical boron concentration, Tbc, CHC, oxide surface temperature, and pellet centerline temperature. Overall, MPCORE framework with two-way coupling provides a more accurate and reliable analysis of safety parameters for nuclear reactors.

Low-temperature polycrystalline silicon level shifter using capacitive coupling for low-power operation

  • Chung, Hoon-Ju;Sin, Yong-Won;Cho, Bong-Rae
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.21-23
    • /
    • 2010
  • A new level shifter using low-temperature polycrystalline silicon (poly-Si) thin-film transistors (TFTs) for low-power applications is proposed. The proposed level shifter uses a capacitive-coupling effect and can reduce the power consumption owing to its no-short-circuit current. Its power saving over the conventional level shifter is 72% for a 3.3 V input and a 10 V output.

Prism-Coupling 방법에 의한 이온교환 도파로 해석 (Analysis of ion-exchanged waveguides by using Prism-Coupling method)

  • 박정일;박태성;이현용;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.37-39
    • /
    • 1994
  • We have investigated the characteristics of planar optical waveguides formed by silver ion-exchange. Experimental values of the effective indices of guided modes were obtained by measuring the synchronous angles of strongest coupling. Definition of an effective diffusion constant leads to the mode-dispersion curves applicable over a wide range of fabrication conditions. In order to compare experimental and theoretical results, We have plotted each mode index of a wide range of fabrication conditions.