• Title/Summary/Keyword: Overall efficiency

Search Result 2,350, Processing Time 0.03 seconds

Analysis of Efficiencies of Scroll Expander for Micro Scale Organic Rankine cycle (초소형 유기랭킨사이클용 스크롤팽창기 효율 특성 분석)

  • Shin, Dong Gil
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.398-401
    • /
    • 2012
  • In this Study, efficiencies of the scroll expander under development for organic Rankine cycle using engine waste heat of vehicle have been analyzed and compared with the commercial scroll expander. While operating organic Rankine cycle for analysing expander efficiencies, power of expander, inlet temperature of expander, inlet pressure of expander and the flow rate of the working fluid(refrigerant R134a) have been measured. Overall efficiency of the expander has been shown the very low level compared with the overall efficiency of the commercial expander. Especially, because the low volumetric efficiency has much effect on overall efficiency, the working fluid leakage trouble of expander has to be solved surely for improvement of the expander overall efficiency.

A Study on Thermodynamic Efficiency for HTSE Hydrogen and Synthesis Gas Production System using Nuclear Plant (원자력 이용 고체산화물 고온전기분해 수소 및 합성가스 생산시스템의 열역학적 효율 분석 연구)

  • Yoon, Duk-Joo;Koh, Jae-Hwa
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.416-423
    • /
    • 2009
  • High-temperature steam electrolysis (HTSE) using solid oxide cell is a challenging method for highly efficient large-scale hydrogen production as a reversible process of solid oxide fuel cell (SOFC). The overall efficiency of the HTSE hydrogen and synthesis gas production system was analyzed thermo-electrochemically. A thermo-electrochemical model for the hydrogen and synthesis gas production system with solid oxide electrolysis cell (SOEC) and very high temperature gas-cooled reactor (VHTR) was established. Sensitivity analyses with regard to the system were performed to investigate the quantitative effects of key parameters on the overall efficiency of the production system. The overall efficiency with SOEC and VHTR was expected to reach a maximum of 58% for the hydrogen production system and to 62% for synthesis gas production system by improving electrical efficiency, steam utilization rate, waste heat recovery rate, electrolysis efficiency, and thermal efficiency. Therefore, overall efficiency of the synthesis production system has higher efficiency than that of the hydrogen production system.

Performance Analysis of Contactless Electrical Power Transfer for Maglev

  • Hasanzadeh, S.;Vaez-Zadeh, S.
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.115-123
    • /
    • 2012
  • Contactless electrical power transfer through an air gap is a revived technology for supplying energy to many movable applications including Maglev. In this paper, magnetic equivalent circuits and analytical models of contactless electrical power transfer systems are developed and evaluated through experiment. Overall coupling coefficient and overall efficiency are introduced as means for evaluating the systems' performance. Compensating capacitors in primary and secondary sides of the systems improve the overall coupling coefficient and overall efficiency. Using the analytical models, the effects of different parameters and variables such as air gap and load current are analyzed to give a high coupling coefficient and an improved efficiency of power transfer for different compensation structures.

A Study on the Efficiency of Fuel Cells for Marine Generators (선박 발전기용 연료전지 시스템의 효율에 관한 연구)

  • Lee, Jung-Hee;Kwak, Jae-Seob;Kim, Kwang-Heui
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.52-57
    • /
    • 2018
  • Most current ships have adopted on-board diesel generators to produce electricity, but the overall efficiency of equipment is down to about 50% due to thermal losses from operations such as exhaust gas, jacket water cooler, scavenge air cooler, etc. Recently, fuel cells have been highlighted as a promising technology to reduce the effect on the environment and have a higher efficiency. Therefore, this paper suggested a solid oxide fuel cell (SOFC)-gas turbine (GT) using waste heat from a SOFC and SOFC-GT-steam turbine (ST) with Rankine cycle. To compare both configurations, the fuel flow rate, current density, cell voltage, electrical power, and overall efficiency were evaluated at different operating loads. The overall efficiency of both SOFC hybrid systems was higher than the conventional system.

Overall Performance characteristic for 300MW Taean IGCC Plant (300MW 태안 IGCC 플랜트 종합성능 특성)

  • Kim, Hakyong;Kim, Jaehwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.129.2-129.2
    • /
    • 2010
  • As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.

  • PDF

An Analysis of Economic Efficiency of Environmental Friendly Farms and Conventional Farms : the Case of Strawberries and Tomatoes farms (친환경농가와 관행농가의 경영효율성에 관한 연구: 딸기와 토마토를 중심으로)

  • Han, Byeol;Yang, Sung-Bum
    • Korean Journal of Organic Agriculture
    • /
    • v.25 no.4
    • /
    • pp.679-697
    • /
    • 2017
  • This study analyzes an economic efficiency of environmental friendly farm and conventional farm using the data envelopment analysis (DEA). We compare the economic efficiency of Environmental Friendly farm and Conventional farm. We also analyze the effects of some explanatory variables on allocative efficiency (AE), pure technology efficiency (PTE) and scale efficiency (SE). In the case of strawberries farm, environmental friendly farm has higher overall efficiency (OE) than conventional farm. But tomatoes farm has higher overall efficiency (OE) than conventional farm. And We measure returns to scale of farms. Most strawberries and tomatoes farms showed Increasing to Scale (IRS).

An Assessing of Franchisor's Firm Performance Based on Data Envelopment Analysis (DEA 분석을 통한 프랜차이즈 기업의 평가)

  • Kim, Seonmin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.359-369
    • /
    • 2014
  • Due to the severe market conditions, pre-entrepreneur seeks to start their business through franchise company. This paper, using the data envelopment analysis(DEA) method, examines efficiency of a group of franchise company in order to provide efficiency information with pre-entrepreneur. Output-oriented DEA model is applied in the investigation of efficiency, and the overall efficiency score is decomposed into pure technical efficiency and scale efficiency. The input variables selected to evaluate the efficiency are franchise deposit, franchise contribution cost and the output variables are sales and number of franchises, and length of business. The results of this paper show franchise industry have the low level of overall efficiency and the main sources of inefficiency is found technical rather than scale. As a result, this paper provides not only the current status of efficiency information of a franchise with pre-entrepreneur but also give warning when they sign-up with franchise business.

Overall efficiency enhancement and cost optimization of semitransparent photovoltaic thermal air collector

  • Beniwal, Ruby;Tiwari, Gopal Nath;Gupta, Hari Om
    • ETRI Journal
    • /
    • v.42 no.1
    • /
    • pp.118-128
    • /
    • 2020
  • A semitransparent photovoltaic-thermal (PV/T) air collector can produce electricity and heat simultaneously. To maximize the thermal and overall efficiency of the semitransparent PV/T air collector, its availability should be maximum; this can be determined through a Markov analysis. In this paper, a Markov model is developed to select an optimized number of semitransparent PV modules in service with five states and two states by considering two parameters, namely failure rate (λ) and repair rate (μ). Three artificial neural network (ANN) models are developed to obtain the minimum cost, minimum temperature, and maximum thermal efficiency of the semitransparent PV/T air collector by setting its type appropriately and optimizing the number of photovoltaic modules and cost. An attempt is also made to achieve maximum thermal and overall efficiency for the semitransparent PV/T air collector by using ANN after obtaining its minimum temperature and available solar radiation.

Overall Conversion Efficiency for Dimethylsulfide to Sulfur Dioxide in the Marine Boundary Layer-An Overview

  • Shon, Zang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.107-120
    • /
    • 2002
  • Dimethyl sulfide (DMS) is the major sulfur gas released from the ocean. The atmospheric DMS released from the ocean is oxidized mainly by hydroxyl (OH) radical during the day and nitrate (NO$_3$) radical at night to form sulfur dioxide (SO$_2$) as well as other stable products. The oxidation mechanism of DMS via OH has been known to proceed by two channels; abstraction and addition channels. The major intermediate product of the addition channel has been known to be dimethylsulfoxide (DMSO) based on laboratory chamber studies and field experiments. However, a branching ratio for DMSO formation is still uncertain. The reaction of DMSO with OH ultimately produces SO$_2$and dimethylsulfone. The major product of the abstraction channel has known to be SO$_2$from laboratory chamber studies. But overall conversion efficiency for DMS to SO$_2$from DMS oxidation is still inconsistent in the literature. Based on laboratory and field studies, the conversion efficiency from the abstraction channel is likely to be greater than 0.5, while that from the addition channel is likely to be greater than 0.6. Overall conversion efficiency from DMS to SO$_2$might be greater than 0.5 based on the above two values in the remote marine boundary layer (MBL). This high efficiency in the remote MBL is supported by strong coupling between DMS and SO$_2$measurements with high temporal resolution.

Comparative Efficiency of Container Ports in Vietnam and Korea

  • Ly, Pham Thi Hoai;Ahn, Ki-Myung;Ryoo, Dong-Keun
    • Journal of Navigation and Port Research
    • /
    • v.42 no.2
    • /
    • pp.143-152
    • /
    • 2018
  • Currently, there are very few papers that have examined the efficiency of Vietnamese ports. Of those that have, some of them take into account only a few container ports in Northern Vietnam. Others focus on comparing all types of ports in Vietnam with regard to the differences in efficiency scores when applying different methods to evaluate efficiency. However, there is no paper that specifically analyzes the efficiency of Vietnamese container ports throughout the country or that compares Vietnamese container ports with those of other countries in terms of efficiency. In order to provide more accurate and interesting information for container port authorities, in this study, 21 major Vietnamese container ports and seven major Korean container ports are selected and examined with regard to their levels of efficiency in 2016 using data envelopment analysis (DEA). This paper applies both constant return to scale (CRS) and variable return to scale (VRS) to explore the differences among overall technical efficiency, pure technical efficiency, and scale efficiency of the selected container ports. This study also indicate slacks and sets projections for inefficient ports.