• 제목/요약/키워드: Overvoltage

검색결과 359건 처리시간 0.02초

개폐과전압 발생시 지중송전선로 편단접지 구간에서 SVL에 미치는 과도특성에 관한 연구 (A Study on SVL Transient Characteristics by Switching Overvoltage at Single Point Bonding Section in Underground Transmission Cables)

  • 정채균;강지원
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.764-769
    • /
    • 2014
  • This paper describes sheath voltage limiter(SVL) transient characteristics by switching overvoltage considering single point bonding in underground transmission cables. The crossbonding system is generally used for grounding methods of underground transmission system. However, the single point bonding system is used in selective area which is difficult to consist of crossbonding major section. The sheath voltage limiters are connected between joints in the single point bonding. Specially, the high overvoltage might be generated in that section as well as the aging of sheath voltage limiter might be progressed by various electrical stress including lightning overvoltage, switching overvoltage and power frequency overvoltage. Therefore, in this paper, the switching overvoltage characteristics in underground cables are firstly analysed using EMTP simulation. Then, the switching overvoltage of sheath voltage limiter is also studied in single point bonding. Finally, the reduction method of sheath voltage limiter switching overvoltage is proposed by various simulation studies including circuit breaker operating order.

345kV 지중 및 혼합 송전계통에서의 개폐 과전압 해석 (Analysis of Switching Overvoltage in 345kV Underground and Combined Transmission Systems)

  • 정채균;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.713-721
    • /
    • 2003
  • This paper analyzes the switching overvoltage occurred on 345kV underground power cable system as well as combined transmission system using EMTP. Cable length and closing time, preinsertion resistance have effect on switching overvoltage. Therefore, this paper analyzes the switching overvoltage occurred on conductor and sheath with change of those parameters. Specially, the cross bonding position becomes discontinuity point because of the difference between surge impedance of metal sheath and that of lead cable. Thus, the transmission and the reflection of traveling wave complexly occur at this connection point. According to these influences, voltage between sheath and earth as well as voltage between joint boxes rise. Time to crest point of switching overvoltage is longer than lightning overvoltage. Even though the voltage induced by switching surge is smaller than lightning surge, that voltage may have serious effect on the metal sheath. Therefore, this paper also analyses the reduction effect of switching overvoltage when the preinsertion resistance of circuit breaker is considered.

Introduction of Insulation Coordination for UHV AC Systems

  • Shim, Eungbo;Zaima, Eiichi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1293-1297
    • /
    • 2015
  • This paper introduces the insulation coordination study results for UHV AC systems which was performed by CIGRE working group. The study results will be discussed within IEC technical committee in order to amend the IEC Insulation Coordination 60071-1 Ed. 8 2010 and 60071-2 Ed. 3, 1996. This paper includes the insulation coordination of transformer, gas insulated switchgear, metal oxide arresters and clearances of transmission towers. This article also illustrates the overvoltage specific to UHV systems such as TOV(temporary overvoltage), switching overvoltage, lightning overvoltage and VFTO(very fast transient overvoltage).

IGBT 스위칭시 괴전압 제한을 위한 게이트 구동기법 (An Improved Gate Control Scheme for Overvoltage Clamping Under High Power IGBTs Switching)

  • 김완중;최창호;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.323-327
    • /
    • 1998
  • Under high power IGBTs Switching, a large overvoltage is induced across the IGBT module due to the stray inductance in the circuit. This paper proposes a new gate drive circuit for high power IGBTs which can actively suppress the overvoltage across the driven IGBT at turn-off while preserving the most simple and reliable power circuit. The turn-off driving scheme has adaptive feature to the amplitude of collector current, so that the overvoltage can be limited much effectively at the fault collector current. Experimental results under various normal and fault conditions prove the effectiveness of the proposed.

  • PDF

345kV 계통 재투입과 전압 해석 (A Study on the Reclosing Overvoltage in 345 [kV] Transmission Line)

  • 윤재영;박동욱;황치우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.166-169
    • /
    • 1990
  • The purpose of the circuit breaker on power system is to disconnect the faulty part from the system and to maintain the integrity of the system. With switching overvoltages are generated. When the system voltages become higher, switching overvoltage is important factor in insulation co-ordination. Since the no-load reclosing overvoltage with inductive source is severe, this paper deals with the reclosing overvoltage and the effect of closing resistor. This reclosing overvoltage of 27-bus model system with and without closing resistor is analyzed by using EMTP (Electro-Magnetic Transients Program) for both deterministic and Stochastic model.

  • PDF

Overvoltage Protection Controller Design of Distributed Generation Connected to Power Grid Considering Islanding Condition

  • Cha, Jae-Hun;Park, Kyung-Won;Ahn, Hong-Seon;Kwon, Kyoung-Min;Oh, Jin-Hong;MAHIRANE, Philemon;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.599-607
    • /
    • 2018
  • Distributed generation (DG) is being highlighted as an alternative for future power supplies, and the number of DG systems connected to conventional power systems is steadily increasing. DG generators are designed using power electronics and can give rise to various power quality problems, such as overvoltage or overcurrent. Particularly, unintentional islanding operation can occur in a conventional power system when the power grid is separated from the DG systems. Overvoltage may occur in this situation, depending on the power generation and power consumption. However, overvoltage phenomena might not happen even when islanding occurs. Therefore, it is necessary to analyze the fault characteristics during islanding. In this study, a fault analysis of islanding operation was carried out using PSCAD/EMTDC, and a countermeasure for the overvoltage problem is proposed.

멀티레벨 인버터 구동 고압유도전동기에시 발생하는 과도과전압 저감을 위한 LCR필터의 효과분석 (Analysis on the Effect of LCR Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter)

  • 김재철;권영목
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.45-52
    • /
    • 2006
  • 본 논문에서는 H-bridge cascaded 7-level 인버터로 구동되는 고압 유도전동기에서 발생하는 과도과전압 저감을 위한 LCR 필터의 효과를 분석하였다. 인버터에서 발생하는 스위칭 서지 전압은 유도전동기 입력단자에서 과도과전압을 발생시킨다. 이 과도과전압은 고압 유도 전동기의 고정자 권선에 심각한 전압스트레스를 주어 전동기 절연사고를 발생시키는 주요원인이다. 과도과전압의 영향은 저압유도 전동기 보다 고압 유도전동기에서 더욱더 심각하게 발생한다. 이러한 과도과전압을 저감하기 위한 방안으로 LCR 필터를 선택하였으며, 필터를 인버터 출력단자에 연결하여 과도과전압 스트레스와 링잉을 저감한 것을 전동기 단자에서 전압파형과 고조파 스펙트럼을 통하여 증명하였다. 시뮬레이션은 전자계과도해석 프로그램인 EMTP(Electromagnetic Transients Program)을 사용하였다.

발전기 과여자 및 과전압 계전기 보호협조에 관한 연구 (A Study on the Protective Coordination of Generator Overexcitation and Overvoltage Relay)

  • 박지경;김광현;김철환;유영식;양정재
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1187-1194
    • /
    • 2017
  • After North American wide area black out on August 14, 2003, various studies have been conducted to find out the reason of the disaster. One of main reasons was misoperation of generator protection system. Since then, protective coordination between generator protection system and excitation system controls has been hot issue among electrical engineers. Among various generator protection relays, in this paper, we focused on generator overvoltage and overexcitation relay, which protect the over-flux condition of the generator. Thus, at first, we modeled the generator overvoltage, overexcitation relay and detailed power system including excitation system, governor and etc., based on actual field data. And then, we reviewed the protective coordination of generator overvoltage and overexcitation relay using electromagnetic transient program. In addition, we discussed the protective coordination method for redundant protection relays in both automatic voltage regulator and generator side.

과전압 제한 기능을 갖는 새로운 IGBT 게이트 구동회로 (Improved Gate Drive Circuit for High Power IGBTs with a Novel Overvoltage Protection Scheme)

  • 이황걸;이요한;서범석;현동석;이진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.346-349
    • /
    • 1996
  • In application of high power IGBT PWM inverters, the treatable power range is considerably limited due to the overvoltage caused by the stray inductance components within the power circuit. This paper proposes a new gate drive circuit for IGBTs which can actively suppress the overvoltage across the driven IGBT at turn-off and the overvoltage across the opposite IGBT at turn-on while preserving the most simple and reliable power circuit. The turn-off driving scheme has adaptive feature to the amplitude of collector current, so that the overvoltage is limited much effectively at the larger collector current. The turn-on scheme is to decrease the rising rate of the collector current by increasing input capacitance during turn-on transient when the gate-emitter voltage is greater than threshold voltage. The experimental results under various normal and fault conditions prove the effectiveness of the proposed circuit.

  • PDF

과전압 분석 결과와 고장특성을 고려한 기설 송전선로의 절연보강 방법에 관한 연구 (A Study on Insulation Performance Enhancement of Existing Transmission Line Considering Overvoltage Analysis Result and Fault Characteristic)

  • 곽주식;우정욱;구교선;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.162-168
    • /
    • 2009
  • 본 논문은 이미 표준 절연설계 값으로 건설되어 운전중인 송전선로의 절연거리를 과전압분석결과, 뇌사고 및 오손 고장 확률과 특성을 고려하여 재설계하고 소요 애자수량을 결정하기 위하여 수행된 연구결과이다. 송전선로의 절연성능을 훼손하지 않으면서 적절한 절연거리를 확보하기 위하여 EMTP 모델을 이용하여 선로에서 발생 가능한 최대 과전압을 계산하고, 뇌 고장실적 및 뇌사고율 예측계산결과와 오손 고장 확률을 조사 분석하였다. 분석결과로부터 고장 특성을 고려한 소요 애자수량의 결정방법을 제시한다.