• 제목/요약/키워드: Overvoltage

검색결과 359건 처리시간 0.027초

GTO를 이용한 과전압 억제용 크로바 회로 (Crowbar Circuit for the Overvoltage Protection Using GTO)

  • 류호선;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.343-345
    • /
    • 1996
  • In the case of synchronous machines, certain power system disturbances cause current to assume negative values when no static converter is present. But the converter prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. The crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly. The newly proposed circuit is verified through simulation and experiment

  • PDF

3-레벨 GTO 인버터를 위한 새로운 스너버회로 설계 (A Snubber Design for Low Power Dissipation and Overvoltage Limitation in Three-Level GTO Inverters)

  • 서재형;서범석;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.153-155
    • /
    • 1994
  • This paper presents a new low loss snubber including the overvoltage snubber for three-level GTO inverters. The proposed snubber can not only minimizes the snubber loss and the number of components but also improve blocking voltage balancing problem between the inner and the outer GTOs.

  • PDF

Zn-Co 합금도금의 조성에 미치는 전해조건의 영향 (Effect of Electrolytic Condition on Composition of Zn-Co Alloy Plating)

  • 강수영
    • 한국융합학회논문지
    • /
    • 제8권11호
    • /
    • pp.287-292
    • /
    • 2017
  • 자동차 부품에 Zn의 전기도금이 적용되고 있다. Zn 도금은 내식성을 증가시키기 위해 두께를 증가시키고 있다. 도금층의 두께가 증가함에 따라 전기도금 층이 파괴되는 문제가 제기되고 있다. Zn계 합금의 전기도금은 내부식성 향상 및 도금 두께 감소를 위해 연구되어 있다. 여러 합금 도금 중에 Zn-Co 합금 도금은 많은 관심을 받고 있다. 본 연구에서는 온도, 전류 밀도 및 전해용액 속 Co 함량과 같은 다양한 제조 조건에서 Zn-Co 전착의 조성을 조사하여 시료의 Co 함량에 대한 전기도금 조건의 영향을 파악하였다. 그 결과는 음극 과전압 및 확산 계수에 의해 설명하였다. 전류 밀도가 증가하고, 전해액 온도가 감소하고, 전해액 농도가 감소함에 따라 음극의 과전압이 증가한다. 음극의 과전압이 증가함에 따라 활성화분극보다 농도분극이 중요하게 된다. 농도분극은 확산 층 내에서 물질 전달은 확산에 의해 결정된다. 일정한 농도분극에서는 확산계수가 큰 원소가 다량 확산하게 된다. 즉 음극의 과전압이 증가함에 따라 확산계수가 큰 Zn 함량이 증가한다.

공소결법에 의해 제조된 지지체식 평판형 고체산화물 연료전지 성능 특성 (Fabrication and Characteristics of Supported Type Planar Solid Oxide Fuel Cell By Co-firing Process)

  • 송락현
    • 한국재료학회지
    • /
    • 제13권3호
    • /
    • pp.160-168
    • /
    • 2003
  • The co-firing processes for the supported type planar solid oxide fuel cell were investigated. A flat cell of $7.7${\times}$10.8\textrm{cm}^2$ was fabricated successfully by the co-firing process, in which green films were co-sintered in the forms of two layers of anode/electrolyte or of three layers of anode/electrolyte/cathode with gas distributor. A co-fired cell of two layers yielded a power of 200 ㎽/$\textrm{cm}^2$ at 608 ㎷. Its performance loss was mainly due to iR drop in the anodic gas distributor, which was attributed to poor contact between anodic gas distributor and current collector. The performance in the co-fired cell of three layers was much lower than that of two layers, which resulted from the large iR drop and activation overvoltage at the cathodic side. In the co-fired cell of two layers, the impedance analysis indicated that the performance decay during cell operation is due to both anode overvoltage and iR drop at anode side. Also the electrode reaction of the co-fired two layers' cell is considered to be controlled by activation overvoltage within the low current of 50 ㎃.

해수 내 캐비테이션 환경에서 동합금의 정전위법에 의한 손상 방지 기술 (Damage Protection Technology by Potentiostatic Method of Cu Alloy Under Cavitation Environment in Seawater)

  • 김성종;박재철;장석기
    • 한국표면공학회지
    • /
    • 제46권3호
    • /
    • pp.120-125
    • /
    • 2013
  • This investigation was to identify the electrochemical corrosion protection conditions to minimize the cavitation damage by generating hydrogen gas with the means of hydrogen overvoltage before the impact pressure of the cavity is transferred to the surface. The hybrid potentiostatic test method is designed to evaluate a complexed cavitation and electrochemical characteristic for ALBC3 alloy that is diverse and its broad applications fields in marine industry. The surface observation showed that neither the cavitation damage nor the electrochemical damage by the hydrogen gas generation occurred in the potential of -2.6 V under the cavitation environment. In the potentiostatic experiments under the cavitation environment, the cavities were reflected or cancelled out by the collision of the cavities with the hydrogen gas generated by the hydrogen overvoltage.

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

주택용 분전반에 설치되는 서지보호기의 열적 안전성 시험 및 분석 (A thermal stability testing and analysis for a surge protector installed in residential distribution board)

  • 김주철;박장범;기채옥
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.339-341
    • /
    • 2009
  • 개별세대 내 정보통신기기 및 홈네트워크 장비증가로 인하여 서지보호장치(SPD : Surge Protective Device)가 설치되고 있고 산업규격개정 및 등전위 접지시스템 강화에 따라 서지보호기 사용량은 점진적으로 증가하고 있다. 주택용 분전반에 설치되는 서지보호기의 부품은 전압제한형 소자인 $Z_nO$배리스터가 사용되고 있으나 일시적 과전압특성 (Temporary Overvoltage Characteristic) 위험에 노출되어있다. 본 논문은 일반주택에 사용되는 서지보호기의 열적 안전성 (Thermal Stability) 특성시험을 통하여 제품을 분석하였고 이를 토대로 개선안을 제시하였다. 분석결과 누설전류를 차단하기위한 가스 방전관(GDT) 사용 및 열폭주(Thermal Runaway) 현상을 막기 위한 안전장치가 2종 이상 필요하였다.

  • PDF

IGBT 직렬 연결을 위한 턴-오프 게이트 구동기법 (An Improved Turn-Off Gate Control Scheme for Series Connected IGBTs)

  • 김완중;최창호;현동석
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.99-104
    • /
    • 1999
  • 최근 산업이 대규모화함에 따라 고압 전력 변환 장치의 필요성이 증가하고 있고, 이에 따라 전력용 반도체 소자의 직렬 구동이 많이 이용되고 있다. 소자의 직렬 구동은 소자간에 적절한 전압 분배가 이루어져 개별 소자에 정격이상의 과전압이 인가되는 것을 방지하는 것이 큰 관건이다. 또한 고전압 회로에서는 부유 인덕턴스에 의한 소자의 과전압도 방지하여야 한다. 본 논문에서는 직렬 연결된 IGBT의 턴-오프 과도상태시 컬렉터 전압 기울기 조절로 안정된 전압 분배와 과전압을 방지하는 새로운 게이트 구동기법을 제안한다. 제안하는 게이트 구동기법은 컬렉터 전압을 검출하여 능동적으로 게이트 신호를 제어함으로써 과전압을 제한한다. 새로운 IGBT 게이트 구동회로를 제작하고 직렬 연결된 IGBT 회로에 적용하여 게이트 구동기법의 타당성을 검증하였다.

국내 배전계통의 가공지선 접지조건에 따른 뇌서지 영향 분석 (Analysis of Effect on Lightning Surge according to the Grounding Condition of Overhead Ground Wire in Distribution System)

  • 한준;김철환;서훈철;최선규;이병성
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.331-337
    • /
    • 2014
  • The Korean distribution system consists of overhead ground wire (OHGW), phase conductors and neutral wire. Especially, OHGW is installed over the phase conductors to protect distribution system from the lightning surge. The flashover rate and the magnitude of lightning overvoltage on distribution system can be affected by grounding condition of OHGW such as grounding resistance and grounding interval. In this paper, we conduct an analysis of lightning overvoltage and flashover rate according to the grounding condition of OHGW. The distribution system and lightning surge are modeled by using ElectroMagnetic Transient Program (EMTP). Also, the Monte Carlo method is applied to consider random characteristics of lightning, and the flashover rate is calculated based on IEEE std. 1410. The simulations are performed by changing the grounding resistance and interval of OHGW and the simulation results are analyzed.