• Title/Summary/Keyword: Ozone Concentration

Search Result 760, Processing Time 0.023 seconds

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Synoptic Weather Patterns and Variation of Ozone Concentrations Association with High Ozone Days at Five Major Cities in Korea (고농도 오존이 발생하는 날의 종관 기상 패턴과 주요 5대 도시별 오존 농도 변화)

  • 김유라;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.437-444
    • /
    • 2001
  • The characteristic features of surface ozone concentration and the forecasting procedure of high ozone days have been studied. The ozone concentration was continuously measured during 3 years (1997~1999) at air quality monitoring stations in five major cities in Korea. The diurnal variation of surface ozone concentration on high ozone days is characterized by low ozone concentration at night. The ozone concentration Increases continuously after sunrise, In reach a peak at 1500~1600 LST. Thereafter it decreases steadily to a low concentration at sunset. The diurnal and annual maximum of the surface ozone concentration at Seoul were observed in May and June, respectively. The favorable synoptic condition for the high ozone day is divided into 4 different synoptic weather patterns: a high-pressure system from the Sea of Okhotsk, the Pacific subtropical high extending westward, a moving high-pressure system covering the Korean peninsula. and a synoptic system In front of a typhoon. Most of high ozone days occur under the high pressure system in Korea.

  • PDF

A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan (부산 동삼동 지역의 지표오존농도 특성 연구)

  • Jeon, Byung Il
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

The Measures of Ozone Pollution: An Analysis of Ozone Concentration Data in USA

  • Kim, Hong-J.;Lovell, Sabrina J.;O'Farrell, John;Cho, Yong-Sung
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.47-53
    • /
    • 2008
  • In this study, we analyzed how ozone pollution could be differently measured and how these different measures varied year to year and across the ten most populated cities in the United States, from 1980 to 2000. Although peak values of ozone concentration have been significantly reduced in most polluted U.S. cities for the last 20 years, the annual average values of ozone concentration have not been lowered as much as peak values. Ozone concentration data for each city shows a unique pattern of distribution, central tendency, and also there is a wide variation among different ozone measures. Two different cities with the same annual mean concentration of ozone can experience very different distributions of ozone concentration within a year. Ozone measures also show a wide margin of variability as they are estimated from different ozone monitoring sites within each city. Ozone pollution statistics can be largely varied depending on the choice of measures, monitoring sites, and averaging time period. EPA's new ozone standard of 0.08 ppm averaged over an eight-hour appears to be more stringent than the current maximum ozone standard of 0.12 ppm averaged over one hour.

Correlation analysis of solar radiation and meteorological parameters on high ozone concentration (태양복사 및 기상요소의 고농도 오존형성에 대한 상관성 분석)

  • An, Jae Ho
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.93-98
    • /
    • 2012
  • The concerns on high ozone concentration phenomenon is significantly growing in Seoul metropolitan area including the industry complex area, like Shiwha Banwol area. The aims of this research is the analysis of relationship between high concentrations of $O_3$ and solar radiation parameters in atmosphere. The understanding of the effects of solar radiation intensity, humidity, high air temperature on ozone concentration in a day is very useful to provide a direction for reducing of the high ozone concentration to a local government or a metropolitan government. The correlation analysis between maximum ozone concentration and various meteorological parameters in 2009 - 2011 carried out using IBM's SPSS program. The results showed that the mean correlations coefficient (R) between daily Ozone maximum and solar radiation resulted R = 0.64 during 2011. May - September in 10 air pollution stations. In case of correlations between daily ozone maximum and relative humidity showed negative correlation R = -0.61. The correlation analysis with mean air temperature during 1-3 PM resulted R = 0.29. This low correlation coefficient could be corrected by using of categorized data of ozone concentration. The daily maximum ozone concentration is more dependent on peak solar radiation and high air temperature during 1-3 PM than its simple daily maximum values. The results of this research would be used to develop the high ozone alert system around Seoul metropolitan area. This correlation analysis could be partially integrated to prediction of ozone peak concentration in connection with other methods like classification and regression tree(CART).

Forecasting Ozone Concentration with Decision Support System (의사 결정 구조에 의한 오존 농도예측)

  • 김재용;김태헌;김성신;이종범;김신도;김용국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.368-368
    • /
    • 2000
  • In this paper, we present forecasting ozone concentration with decision support system. Since the mechanism of ozone concentration is highly complex, nonlinear, and nonstationary, modeling of ozone prediction system has many problems and results of prediction are not good performance so far. Forecasting ozone concentration with decision support system is acquired to information from human knowledge and experiment data. Fuzzy clustering method uses the acquisition and dynamic polynomial neural network gives us a good performance for ozone prediction with ability of superior data approximation and self-organization.

  • PDF

Analysis on the Effect of Meteorological Factors related to Difference of Ozone Concentration at the Neighboring Areas in Gijang Busan (인접지역간 오존 농도 차이에 대한 기상요소의 영향분석(부산광역시 기장군을 대상으로))

  • Kim, Min-Kyoung;Lee, Hwa-Woon;Jung, Woo-Sik;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1097-1113
    • /
    • 2012
  • Ozone is the secondary photochemical pollutant formed from ozone precursor such as nitrogen dioxide and non-methane volatile organic compounds(VOCs). The ambient concentration of ozone depends on several factors: sunshine intensity, atmospheric convection, the height of the thermal inversion layer, concentrations of nitrogen oxides and VOCs. Busan is located in the southeast coastal area of Korea so the ozone concentration of Busan is mainly affected from the meteorological variables related to the sea such as sea breeze. In this study the ozone concentrations of Busan in 2008~2010 were used to analyse the cause of the regional ozone difference in eastern area of Busan. The average ozone concentration of Youngsuri was highest in Busan however the average ozone concentration of Gijang was equal to the average ozone concentration of Busan in 2008~2010. The two sites are located in eastern area of Busan but the distance of two sites is only 9km. To find the reason for the difference of ozone concentration between Youngsuri and Gijang, the meteorological variables in two sites were analyzed. For the analysis of meteorological variables the atmospheric numerical model WRF(Weather Research and Forecasting) was used at the day of the maximum and minimum difference in the ozone concentration at the two sites. As a result of analysis, when the boundary layer height was lower and the sea breeze was weaker in Youngsuri, the ozone concentration of Youngsuri was high. Furthermore when the sea breeze blew from the south in the eastern area of Busan, the sea breeze at Youngsuri turned into the southeast and the intensity of sea breeze was weaker because of the mountain in the southern region of Youngsuri. In that case, the difference of ozone concentration between Youngsuri and Gijang was considerable.

Case Study for High Ozone Episode day during Summertime in Busan (부산지역 여름철 고농도 오존 발생의 사례 연구)

  • Jeon, Byung-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.4
    • /
    • pp.303-313
    • /
    • 2003
  • This study was carried out to survey the high ozone episode of summertime in Busan. The selected day was July 18, 1999 and August 24, 2001 which recorded exceed to 12ppb/hr at 3 station in Busan simultaneously. In case July 18, 1999, thick cloud and variable wind made weak ozone concentration during morning hour. And increase of ozone concentration by revolution of mixed layer for morning hour did not occur in this case study day. Photochemical reaction by strong radiation after 1100LST made sharp increase rate of ozone concentration(50ppb/hr). In case August 24, 2001, the meteorological condition of this day was not general wind with gradient force, very clear day with less cloud amount, high insolation and sunshine. Dongsamdong, Beomcheondong, Daeyeondong, and Sinpyeongdong had double peak which twice maximum concentration in the early afternoon and late afternoon. Ozone concentration of this day was in inverse proportion to Nitrogen oxide strongly. Ozone concentration exceed to 60ppb/hr occurred at 1400LST, continued to 2300LST.

A Study about Ozonized Water Making that Use $O_3$ (오존화 기체를 이용한 오존수 제조에 관한 연구)

  • Park, Hyun-Mi;Lee, Chang-Ho;Lee, Sang-Geun;Song, Hyun-Jig;Yoon, Byeng-Han;Lim, Chang-Ho;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.339-342
    • /
    • 2004
  • It is research about special quality of ozone gas concentration and dissolved ozone concentration that show according to change of flow rate when liquefied ozone gas in water. If increase flow rate of ozone gas, ozone concentration increases being proportional and amount to fixed flow rate, dissolved ozone concentration was measured low. When ozone concentration How rate 1000 [ppm], dissolved ozone concentration smelted to flow rate 1.5[Q] for 28 [min] is $0.1740{\sim}0.8020[mg/l]$. Could know that half-life is most short by 3 minutes 8 seconds in flow rate 1.5 [Q]. And ozone smelted 20 minutes later after half-life measurement became disjointing all.

  • PDF

Evaluation of Ozone Condensation System by T.D Method

  • Lee, Hee-Kab;Park, Yong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.2
    • /
    • pp.18-22
    • /
    • 2000
  • An ozone condensation system is evaluated from the viewpoint of an ozone supplier fro oxide thin film growth. Ozone is condensed by the adsorption method and its concentration is analyzed using the thermal decomposition method, The concentration of ozone exceeds 90mol% and ozone is supplied for a sufficiently long time to grow oxide thin films. Investigation of the ozone decomposition rate demonstrates that ozone can be transferred into the film growth chamber without marked decomposition. The ozone concentration is also evaluated using a quardrupole mass analyzer and the accuracy of this method is compared with the results of the thermal decomposition method.

  • PDF