• Title/Summary/Keyword: P-VEP

Search Result 11, Processing Time 0.023 seconds

The Analysis of the P-VEP on the Normal Monocular Vision and Amblyopia in Binocular (앙안에서 정상 단안시와 약시안의 P-VEP 분석)

  • Kim, Douk-Hoon;Kim, Gyu-Su;Sung, A-Young;Park, Won-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • The aim of the study was performed the wave analysis of P-VEP on the normal monocular vision and amblyopia in binocular. The P-VEP of three channels were recorded by the Nicolet system. Five adults (three males, two females, mean=22 years, range=19 to 24) subjects were recorded The subjects were researched the history including the systemic health, medication, genetics, allergy and ocular disease. Visual acuity and stereopsis were recorded for each subject monocularly and binocularly. Also subjects viewed the P-VEP stimulus both monocularly and binocularly through the corrected visual acuity during the VEP were recorded. The results of study suggest that the visual acuity of binocularly is better than with monocularly and the stereopsis was about over 140 sec. On the other hand, the analysis of P-VEP suggest that the amplitude of wave is larger when the monocular eye receives the P-VEP stimulus compared with the binocular eye. However the amplitude of wave in amblyopia had more smaller than the normal monocular The latency period of P-VEP was similar to results between the normal eye and binocular vision. But the amblyopia was a long period compared with the normal monocular and binocular vision. In conclusion, this study indicated that the visual acuity of binocularly have a better than the normal monocular vision, But in the P-VEP test, the amplitude of wave on normal monocularly vision appears to be better through the binocularly. But the amblyopia appeared the low amplitude wave of P-VEP and decreased the visual acuity.

  • PDF

The Effects of Visual acuity increase in mono vision by the P-VEP study using Netspeg lens (Netspag Lens를 이용한 Mono vision에서 시력개선 효과에 대한 P-VEP 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.241-246
    • /
    • 2005
  • The aim of the study was performed the wave analysis of P-VEP on the development of visual function using Netspeg lens in monocular of refraction error subjects. The P-VEP of three channels were recorded by the Bausch Lomb system. Ten adults (five males, five females, mean=22 years, range=19 to 23) subjects were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, ocular disease, and so on. Visual acuity and refraction test were performed for each subject with mono vision by using the Netspeg lens. Also subjects viewed the P-VEP stimulus with mono vision through the corrected visual acuity with Netspeg lens during VEP test. The results of study suggest that the mono vision using Netspeg lens is better than with non-Netspeg lens on the visual acuity and image symptom. On the other hand, the analysis of P-VEP suggest that the amplitude of wave is larger when the eye using Netspeg lens receives the P-VEP stimulus compared with the non Netspeg lens. Also, on the wave style of P-VEP, the eye of Netspeg lens was more stable compared with the naked eye. However, on latency period of P-VEP, the eye of non Netspeg lens was more longer than the eye of Netspeg lens. But, on the other hand, the right and left eye have similar results. In conclusion, this study indicated that the visual acuity and visual function of eye of Netspeg lens used have a better than the eye of non-Netspeg lens in Mono Vision.

  • PDF

Study about PR-VEP Characteristics on Perception Function and Judgement Function of MBTI (MBTI의 인식기능(S/N), 판단기능(T/F)에 대한 PR-VEP 특성연구)

  • Seol, Jee-Yong;Park, Pyong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5485-5491
    • /
    • 2015
  • The purpose of this study is to investigate PR-VEP characteristics on the perception function(S/N) and the judgement function(T/F) of MBTI. The 136 study participants, over 20 years old adults, were examined by PR-VEP and MBTI test for two months in July and August in 2013. PR-VEP was conducted in O1 and O2 by 32 channels EEG system and MBTI test was measured by Form-M online. We found that the time interval(Duration) between N75 and P100 of PR-VEP was 5.49 ms significantly shorter in the group preferring S indicator. And the latency until N75 was 4.83 ms significantly shorter in O1 and 4.27 ms shorter in O2 in the group preferring F indicator. According to these, the characteristics of groups preferring S and F indicator have influence on visual cognitive function, which is meaningful that the interpretation of brain-science can be used with recognition/judgement function of MBTI.

Measuring System of Visual Evoked Potential (VEP) in Mice using BioPAC Modules (BioPAC 모듈을 이용한 마우스 시각유발전위 측정 시스템 확립)

  • Lee, Wang Woo;Ahn, Jung Ryul;Goo, Yong Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.16-24
    • /
    • 2017
  • For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.

The Changes of VEP Values According to the Luminance Conditions and Refractive Errors in Normal Persons (정상인에서 조도와 굴절이상도에 따른 시유발전위 검사 값의 변화)

  • Leem, Hyun Sung;Lee, Koon Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.111-117
    • /
    • 2007
  • The visual evoke potential(VEP) is the effective method to diagnose and treat the amblyopia or to check the infants visual ability. In order to evaluate the changes of P100 latencies and amplitudes of VEP by intensity of illumination and refractive errors, we measured latencies and amplitudes of 41 normal adults (20/20 VA) who have no ocular diseases and neurologic diseases. The results were as follows: In the scotopic condition, the latencies were N75$75.83{\pm}3.69$ msec, P100$103.48{\pm}5.34$ msec, the P100 amplitude was $14.86{\pm}2.43$ msec, and in the photopic condition, the latencies were N75$76.71{\pm}3.11$ msec, P100$107.26{\pm}5.54$ msec and the P100 amplitude was $10.35{\pm}1.75$ msec. The latencies and amplitudes of P100 in the photopic condition had higher values than those in the scotopic condition and the measures were significantly different between the scotopic and photopic condition (p<0.01). The P100 latencies were delayed both in the scotopic and photopic condition with the refractive errors and those measures were delayed more than in the photopic condition. The P100 amplitudes in the induced myopic and hyperopic conditionsreduced than in the emmetopes in both illumination conditions. The P100 latencies and amplitudes in emmetropes showed a correlation with the induced myopic conditions in the scotopic condition. Those results showed that P100 latencies and amplitudes are dependent on the illumination conditions and refractive errors. And we suggest that those results would be useful to determine and evaluate the normal range for the person considering patients' refractive errors and illumination of the test room.

  • PDF

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

Event Related Potential and Neuropsychological Tests (사건 관계 전위와 신경심리 검사)

  • Lee, Sung-Hoon;Koo, Ae-Sook;Woo, Jong-Ho;Kim, Byung-Gun
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.1
    • /
    • pp.76-86
    • /
    • 1994
  • Objectives: This research was performed in order to observe the neuropsychological implication and functional anatomical source of event related potentials(ERP) by studying of correlations between event related potentials and neuropsychological tests. Methods: The latency and voltage of P100 of visual evoked potential (VEP), and N120 and P300 of event related potentials were studied in 56 patients and their correlations with neuropsychological tests were computed. Results: The tests showing significant correlation with latency P100 were visual continous performance test(VCPT) and contingent continous performance test(CCPT) without any significant correlation with voltage of P100. In latency of N120 category test and verbal IQ of KWIS showed significant correlation, and in voltage of N120, finger tapping test, VCPT, CCPT and digit symbol test displayed significant correlations. The latency of P300 had significant correlation with trail making A test and Stroop test. In the voltage of P300 significant correlations were shown with trail making B test, digit symbol test and Wechsler memory scale, finger tapping test, stroop test, VCPT and CCPT. Conclusion : N120 may be considered to reflect the function of medial frontal lobe and P300 may be considered to be developed from the subcortical connection of medial temporal lobe, hippocampus, thalamus, basal ganglia and medial frontal lobe.

  • PDF

Long-Term Effects of the DHA Supplementation on Physical and Brain Development in Full-Term Infants (장기간에 걸친 DHA 보충이 영아의 신체발육 및 두뇌발달에 미치는 영향)

  • 정현주
    • Journal of Nutrition and Health
    • /
    • v.31 no.8
    • /
    • pp.1295-1306
    • /
    • 1998
  • Recent research indicates that the n-3 fatty acid , docosahexaenoic acid(22 : 6n 3, DHA) plays an essential role in infant brain development . DHA is highly concentrated in brain and retinal tissues and accumulates during late fetal and early neonatal life. Diets deficient in DHA are associated with reduced levels of DHA in brain and retinal tissues. The purpose of this study is to investigate the long term effects of DHA supplementation on the growth and mental development of full-term infants. THirty four healty infants were recruited from those who were delivered at Kyung Hee Medical Center. The experimental groups were the breast milk+DHA(-) group who were fed human milk for 20 weeks after birth and thereafter were fed placebo formula for 28 weeks, the breast milk+DHA(+) group who were fed human milk for 20 weeks after birth and thereafter were fed DHA supplemented formula for 28 weeks, DHA(-) group who were fed placebo formula for 48 weeks, and DHA(+) group who were fed DHA supplemented formula for 48 weeks. The daily average intake of DHA for the breast milk+DHA(-) , breast milk+DHA(+), DHA(-) and DHA(+) groups were 39.1mg, 89.9mg, 17.7mg, and 160.224mg, respectively. The results showed that measurements of infant weight, length, head, and chest circumferncewere all in normal range and they were not influenced by the DHA supplements in their diets. There was a significant correlation between dietary DHA intake and erythrocyte DHA level. The results of flash visual evoke potential (VEP) test were not correlated with eerythrocyte DHA and dietary DHA levels at 48 weeks of age. No differences were found in Bayley mental and Psychomotor Development lndex scores among the four experimental groups at 48 weeks of age. Unlike the short-term effects there was no long-term effect of relatively small amounts of dietary DHA supplements on the scores for flash VEP and Bayley test, even thour호 there was an elevated DHA supplements on the scores for flash VEP and Bayley test, even through there was an elevated DHA content in the infants erythrocytes.

  • PDF

Theoretical Study of the Cobalt Substituting Site in the Framework of $AlPO_{4}-5$ Molecular Sieves

  • Sang Joon Choe;Dong Ho Park;Do Sung Huh
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.55-58
    • /
    • 1993
  • In order to determine the cobalt substituting site in $AlPO_4-5$ framework, ASED-MO theory has been used. The substitution of cobalt for aluminum is energetically more favorable than that for phasphorous. The stabilized energy of the former is 51 eV lower than that of the latter. The calculated net charge was +1.27 for Al, +0.85 for P, and +1.56 for Co, respectively. The valence electron population (VEP), reduced overlap population (ROP) and net charge for the charged cluster models were compared for $AlPO_4-5$ and $CoAlPO_4-5$ systems. Then, twe find that the covalency of P-O bond was greater than that of Al-O bond.

Investigation of Visual Perception Under Zen-Meditation Based On Alpha-Dependent F-VEPs

  • Liao, Hsien-Cheng;Liu, Chuan-Yi;Lo, Pei-Chen
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.384-391
    • /
    • 2006
  • Variation of brain dynamics under Zen meditation has been one of our major research interests for years. One issue encountered is the inaccessibility to the actual meditation level or stage as a reference. In this paper, we propose an alternative strategy for investigating the human brain in response to external flash stimuli during Zen meditation course. To secure a consistent condition of the brain dynamics when applying stimulation, we designed a recording of flash visual evoked potentials (F-VEPs) based on a constant background EEG (electroencephalograph) frontal $\alpha-rhythm$ dominating activities that increase significantly during Zen meditation. Thus the flash-light stimulus was to be applied upon emergence of the frontal $\alpha-rhythm$. The alpha-dependent F-VEPs were then employed to inspect the effect of Zen meditation on brain dynamics. Based on the experimental protocol proposed, considerable differences between experimental and control groups were obtained. Our results showed that amplitudes of P1-N2 and N2-P2 on Cz and Fz increased significantly during meditation, contrary to the F-VEPs of control group at rest. We thus suggest that Zen meditation results in acute response on primary visual cortex and the associated parts.