• Title/Summary/Keyword: PAE

Search Result 770, Processing Time 0.028 seconds

Polypropylene/Polyamide Elastomer Blends: Morphology and Mechanical Property (폴리프로필렌/폴리아미드 엘라스토머 블렌드: 모폴로지와 기계적 물성)

  • Liu, Qingsheng;Xu, Yan;Zhang, Hongxia;Li, Yuhao;Deng, Bingyao
    • Polymer(Korea)
    • /
    • v.38 no.5
    • /
    • pp.613-619
    • /
    • 2014
  • The polypropylene/polyamide elastomer (PP/PAE) blends were prepared by melt mixing. PP and PAE in PP/ PAE were immiscible completely. The size of PAE domains was large and the clear gap in the interface between PP and PAE existed, which did not meet the conditions enhancing toughness of polymers by elastomer. Therefore, maleic anhydride grafted polypropylene (MP) was used to improve the miscibility between PP and PAE. The miscibility between PP and PAE was improved and the size of dispersed phase PAE decreased by introducing MP. The crystallization of PP became easier by introducing PAE as a nucleating agent. With the increase of PAE content, the melt-crystallization temperatures of PP components in PP/PAE/MP blends increased gradually. The melt-crystallization of the polytetramethylene oxide segment of PAE component in PP/PAE blends were hampered by PP component. In addition, PAE can enhance significantly the toughness of PP, and the tensile strength and modulus did not decrease.

Enhancement of Paper Characteristics by Polyvinyl Alcohol/Polyamide-epichlorohydrin Coating as a Complex Strength Additive (Polyvinyl Alcohol/Polyamide-epichlorohydrin 복합 지력증강제에 의한 종이 특성 향상)

  • Jang, Yunjae;Lee, Hwaljong;Kang, Ho-Jong
    • Polymer(Korea)
    • /
    • v.38 no.5
    • /
    • pp.620-625
    • /
    • 2014
  • The effect of polyvinyl alcohol/polyamide-epichlorohydrin (PVA/PAE) complex strengthening additive on dry and wet strength and surface properties of paper was investigated. The enhancements of dry and wet strength and dimensional stability were found when PVA/PAE was applied as a complex strengthening additive compared with the cases of applying individual PVA or PAE. This was understood as physical crosslinking between PVA and PAE in the PVA/PAE complex strength additive. This complex strengthening additive also lowered surface roughness and increased sizing. As a result, PVA/PAE complex strengthening additive provided the distinctive gain dot in printed papers.

Adsorption Thermodynamics of Polyamidoamide Epichlorohydrin Polymer in an Aqueous Fibrous Suspension (섬유 현탁액내 PAE 고분자 흡착의 열역학적 고찰)

  • Sung-Hoon Yoon;Kwang-Suk Joo;Tae-Won Lee;Kun-Han Kim;Byung-Bin Park
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.3
    • /
    • pp.220-228
    • /
    • 2003
  • This study was to examine the thermodynamic features of polyelecrolytic adsorption of polyamidoamine-epichlorohydrin(PAE) in a papermaking wet-end. The PAE adsorption experiments were conducted in a stirred jar containing an aqueous fibrous suspension and evaluated in terms of Langmuir and Freundlich parameters. The electrokinetic property of a stock was examined by measuring the zeta potential of each colloidal suspension. The polyelectrolytic PCD titration was employed to determine the adsorbed amounts of PAE polymer. The zeta potential of a stock, being varied significantly depending upon the addition of PAE polymer, showed initially a sharp increase and later an exponential decay as a function of time . The PAE adsorption exhibited a pseudo-Langmuir adsorption behavior at$20^{\circ}C$ , whereas its Freundlich power(v) increased in a proportional way at an elevated temperature. The train numbers calculated on the basis of adsorption thermodynamics were 7 to 8. The length of the extended loop of PAE was calculated as 215 nm at $20^{\circ}C$ and increased at a rate of 9% at every $10^{\circ}C$ rise in temperature. The PAE adsorption was proven to be an exothermic physisorption with the estimated adsorption enthalpy of -27 to -29 kJ/mol.

Polymer Adsorption and fiber Dispersion Stability of a Paper Stock Colloidal Suspension with a PAC-PAE Dual Polymer System (PAC-PAE 2중 고분자 내첨 지료의 고분자 흡착 및 교질 분산계의 안정성 연구)

  • 윤성훈;김태영;김덕기;송병규
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.2
    • /
    • pp.18-25
    • /
    • 2003
  • The adsorption of co-cationic dual polymer system was investigated as was the fiber dispersion stability of a paper stock suspension. Polyaluminum chloride(PAC) and polyamidoamine epichlorohy-drin(PAE) polymers were used as wet-end additives. The adsorbed amounts of PAE polymer in a wet stock were measured by using polyelectrolytic PCD titration. The sheet forming experiments were carried out in a standard handsheet machine. Fiber dispersion stability and relative retention were evaluated in terms of M/K non-uniformity index and sheet basis weight, respectively. The PAE polymer adsorption of Langmuir-isothermal type decreased with increasing PAC addition level. The combination of the two cationic polymers presumably exerts a site-blocking effect by the low molecular weight PAC which gives a partial charge neutralization at a minimum level of addition. From a thermodynamic view point of PAE adsorption, an increase in adsorption entropy and a decrease in train number suggests that the PAR polymer has an extended conformation structure that potentially leads to an enhancement of the fiber dispersion stability. This conclusion is supported by handsheet experiments that examined the PAC-PAE dual polymer effects on the sheet formation and retention.

Change of PAE according to Detector Measurement Method (검출기 측정방법에 따른 PAE값의 변화)

  • Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • The aim of this study is to investigate PAE, as the result of the test of kVp accuracy, according to detector measurement method. Based on the indicated value of 70kVp, each distance between a focus and a kVp meter was 100cm, 80cm and 60cm and the angle of X-ray tube was set on $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$. Each indicated value, 60kVp, 70kVp, 80kVp, 90kVp and 100 kVp, was used compare Small focus with Large focus. As a result, PAE on the side of cathode was higher than it on the side of anode in the case of 100cm and PAE on the side of anode was higher in the case of 80cm and 60cm. The coefficient rate was stable both the side of cathode and anode in the case of 100cm and it was fluctuated in the case of 80cm and 60cm. PAE in the case of Small focus was higher than Large focus and it was disproportionate to an indicated value. Error rate was in inverse proportion to the indicated value.

Pharmacognostical Studies on the 'Pae Jang' (패장의 생약학적 연구)

  • Park, Jong-Hee;Choi, Jeong-Kyu
    • Korean Journal of Pharmacognosy
    • /
    • v.37 no.4 s.147
    • /
    • pp.302-306
    • /
    • 2006
  • 'Pae Jang (敗醬)' is one of Chinese crude drugs used mainly as a edema, abdominal pain and hemoptysis, etc. With regard to the botanical origin of 'Pae Jang', it has been considered to be Patrinia scabiosaefolia of Valerianaceae, but there has never been studied pharmacognostically. To clarify the botanical origin of the 'Pae Jang', we studied on the anatomical characteristics of the roots of three species growing in Korea. Through our studies, the botanical origin of 'Pae Jang' from Korea was proved to be the under ground portions of Patrinia scabiosaefolia and Patrinia villosa.

The effects of paeoniflorin injection on soluble triggering receptor expressed on myeloid-1 (sTREM-1) levels in severe septic rats

  • Liu, Xiao-Rong;Xu, Jie;Wang, Yi-Min;Ji, Ming-Suo;Liu, Fu-Shan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.6
    • /
    • pp.565-571
    • /
    • 2016
  • Paeoniflorin (PAE) is the most abundant compound in Xuebijing injection widely used to treat sepsis. We aimed to investigate effect of PAE on expression of soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) in a rat model of sepsis. Wistar rats were divided into Normal, Model, and PAE groups (n=20 each). Endotoxin was administrated at 5 mg/ml/kg in Model and PAE rats to establish rat sepsis model. 1 h after endotoxin administration, PAE was administrated at 4 ml/kg in PAE group once per day for 3 days. Routine blood tests and biochemical indexes were assessed, including aspartate aminotransferase (AST) and creatine kinase-MB (CK-MB). The plasma sTREM-1 level was measured using quantitative ELISA. At the end of experiment, the small intestine, liver, kidney and lung were subjected to pathological examinations. A rat model of sepsis-induced multiple organ dysfunction syndrome (MODS) was established successfully with endotoxin administration (5 mg/ml/kg), evidenced by histo-pathological examinations, routine blood tests and biochemical indexes: platelet count decreased and white blood cell count increased (p<0.05), CK-MB and AST increased (p<0.05). PAE treatment significantly reduced the plasma levels of AST, CK-MB, and sTREM-1, compared to Model group (p<0.05). Meanwhile, sepsis-induced damages in the liver, lung, stomach and intestinal mucosa were also markedly ameliorated by PAE treatment. PAE demonstrated a significantly protective effect in a rat model of sepsis by decreasing plasma sTREM-1 level, reducing inflammation, preventing MODS and protecting organ functions.

Evaluating Pharmacological Effects of Two Major Components of Shuangdan Oral Liquid: Role of Danshensu and Paeonol in Diabetic Nephropathy Rat

  • Chen, Ying;Liu, Zhuying;Zhou, Fuxing;Zhao, Hang;Yang, Qian;Li, Hua;Sun, Jiyuan;Wang, Siwang
    • Biomolecules & Therapeutics
    • /
    • v.24 no.5
    • /
    • pp.536-542
    • /
    • 2016
  • Shuangdan oral liquid (SDO) containing radix Salviae miltiorrhizae (Chinese name Danshen) and cortex moutan (Chinese name Mudanpi) is a traditional Chinese medicine using for treating vascular diseases. Danshensu (DSS) is a main effective monomer composition derived from radix Salviae miltiorrhizae and paeonol (Pae) from cortex moutan. Although the two herbs are widely used in traditional Chinese medicine, the pharmacological functions of their active compositions were not reported. Therefore, the research of DSS and Pae in mechanisms and pharmacodynamics interaction can provide scientific evidence to support clinical application. The diabetic nephropathy (DN) rats which were induced by streptozotocin (STZ) were treated with SDO, DSS, Pae, and DSS+Pae for eight weeks. The positive effects on DN animal models were investigated by detection of physiological and biochemical indexes and oxidative stress markers, within five treatments: SDO, DSS, Pae, DSS+Pae and insulin group. Compared with the model group, the DSS+Pae group improved the renal function, blood lipid metabolism and blood viscosity, increased the vitality of T-SOD or T-AOC and decreased the level of MDA or NO after the treatment. The study was successfully showed that the DSS+Pae group could delay the process of DN, especially in the renal injury part of histopathology changes. Our results suggest that the co-administration of DSS and Pae significantly may play a protective role in DN rats through decreasing the oxidative stress and improving the blood lipid metabolism mechanisms.

Adhesive Strength in Tension of High Volume PAE-Modified Cement Mortar with High Flowability for Floor Finishing

  • Do, Jeong-Yun;Soh, Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.739-746
    • /
    • 2003
  • Various researches on the application of polymer dispersions to the cement mortar and concrete have been carried out in many countries like America, Japan and Germany and so on due to their high performance and good modification effect. PAE of polymer dispersion widely used in situ was employed that the high flowability may be induced in the cement mortar. In order to investigate the modification of cement mortar with high flowability by PAE and fracture mode of adhesive strength properties in tension of that, experimental parameters were set as PAE solid-cement ratio(P/C) and cement: fine aggregate(C:F) and the experiments such as unit weight, flow, consistency change, crack resistance and segregation that inform on the general properties have been done. Adhesion in tension is measured with a view to comprehending the properties and fracture mode in tensile load. Consistency change of cement mortar modified by PAE did grow better as the ratio of PAE solid-cement increased and was much superior to that of resin based flooring such as polyurethane and epoxy which recorded the loss of consistency in 90 min. after mixing. Adhesive strength in tension increased with continuity during curing period and showed the maximum in case of C:F=1:1 and P/C=20%.

A Study on PAE of Tube Voltage of Diagnostic X-ray Units -At the area of Sungnam, Inchon, Seoul- (진단용(診斷用) X선장치(線裝置)의 관전압(管電壓) 백분율(百分率) 평균오차(平均誤差)에 관한 조사(調査) 연구(硏究))

  • Lim, Han-Young;Oh, Hyun-Joo;Kim, Young-Il
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.45-50
    • /
    • 1993
  • In this paper, the PAE of tube voltage of 93 diagnostic X-ray units those are using at the 19 general hospitals and 9 local clinics in the area of Sungnam, Inchun, and Seoul have been surveyed. The results are summarized as following. 1. PAE of tube Voltage 70, 100KV at the 56 (60%) X-ray units were ${\pm}7%$ below, at the 8 units (9%), were ${\pm}7%$ above, and those 29 X-ray units (31%) were ${\pm}7%$ below or above with the 70, 100KV tube Voltage in a unit. 2. PAE ${\pm}7%$ below were 68 X-ray units, at the low tube voltage (70KV), and 76 X-ray units at the high tube Voltage (100KV). 3. For six year-use abofe, used X-ray units were PAE ${\pm}7%$ above, and so, the longer used years the more X-ray units became declined in those performance. 4. PAE of tube Voltage were better efficiency at the large capacity 30 X-ray units than small capacity 10. 5. PAE ${\pm}7%$ abovein were only 8 units among 84 diagnostic X-ray units in the general hospitals.

  • PDF