• Title/Summary/Keyword: PD diagnosis

Search Result 228, Processing Time 0.021 seconds

Propagation Characteristics of GIS PD Signals by Dual UHF Band Method (2)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.136-139
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the propagation characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, propagation characteristics of GIS PD signals were measured in the mock-up GIS bus and it was found that the propagation characteristics of the high band showed a better result in accordance with the infernal configuration of the GIS bus than those of the full band.

  • PDF

The Diagnosis technique of Partial Discharges using Antenna (안테나를 이용한 부분방전의 진단기병에 관한 연구)

  • Kim, Young-No;Kim, Jae-Chul;Jeon, Young-Jae;Seo, In-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.217-219
    • /
    • 2001
  • This paper presents new diagnosis technique for detecting a partial discharge(PD) using antenna. The wavelet transform is applied for the analysis of PD pulse signal because it is difficult to identify PD signal using electromagnetic waves detected by antenna. The capabilities of the proposed diagnosis methodology for detecting PD signal is verified on experiment in laboratory.

  • PDF

GlSPD Analysis Using UHF Dual-Band Method (UHF 이중대역법을 이용한 GIS PD 분석)

  • Yi, Sang-Hwa;Choi, Jae-Gu;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

GISPD Analysis Using UHF Dual-Band Method (UHF이중대역법을 이용한 GISPD분석)

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Choi, Jae-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF

Application of Neural Network and 3D Pattern Matching in Partial Discharge Signal

  • Lim Jang-seob;Park Young-sik;Kim Cheol-su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.361-364
    • /
    • 1996
  • Aging diagnosis system using partial discharge(PD) is being highlighted as a research area. But the application of PD requires complicated analysis method because the PD has complex progressing forms. In this paper, It has been developed to the PD diagnosis system using neural network(NN). As a result after NN learning, the recognized rate was represented about 85%. The safety area is possible to express the second output of NN in this experiments.

  • PDF

The Analysis of VHF/UHF PD and 3d-PD Pattern (3d-PD 패턴과 VHF/UHF PD 신호의 고찰)

  • Lim, Jang-Seob;Park, Yong-Sik;Park, Byoung-Ha;Han, Sok-Kyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.75-78
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A study on consistency and accuracy of pulse diagnosis in Eight-Constitution Medicine

  • Shin, Yong-Sup;Nah, Seong-Su;Oh, Hwan-Sup;Park, Young-Jae;Park, Young-Bae
    • Advances in Traditional Medicine
    • /
    • v.9 no.1
    • /
    • pp.14-19
    • /
    • 2009
  • The aim of this study is to evaluate appraiser's consistency and accuracy about pulse diagnosis (PD) in discrimination of eight-constitutions using Gage R&R study. Cumulative numbers of PD for discrimination of eight constitutions of three appraisers' experience were 75,000 cases, 50,000 cases, 1,100 cases, respectively. Three Appraisers diagnosed subject's eight-constitutions by PD with blinded method. Gage R&R study was used to verify the results. In the measurements of consistency, appraiser B (agreement = 80%, Value of k = 0.8276) was very good, appraiser A (agreement = 70%, Value of k = 0.7465) was good, and appraiser C (agreement = 50%, Value of k = 0.5365) was moderate. In the measurements of accuracy, appraiser B (agreement = 70%, Value of k = 0.6812) was good, appraiser A (agreement = 60%, Value of k = 0.6414) was good, and appraiser C (agreement = 0%, Value of k = -0.1000) was poor. The results suggest that accuracy of discrimination of constitutions relatively depend on experience and number of cases of PD. Further large controlled study is needed to evaluate the accuracy of PD.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

Development of On-tine Partial Discharge Monitoring System for High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 운전중 절연감시 시스템 개발)

  • Hwang, D.H.;Sim, W.Y.;Park, D.Y.;Gang, Dong-Sik;Kim, Y.J.;Song, S.O.;Kim, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.224-226
    • /
    • 2001
  • In this paper, a novel high-voltage motor monitoring system (HVMMS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, EMC (Epoxy-Mica Coupler) is used for PD measurement PD signals are continuously measured and digitized with a peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.