• Title/Summary/Keyword: PEMFC

Search Result 914, Processing Time 0.029 seconds

Observation of local water content and current density in the PEMFC system (고분자 전해질 연료전지의 전류밀도와 국소 함수량 관찰)

  • Ko, Dong-Soo;Moon, Cheor-Ron;Choi, Gyung-Min;Kim, Duck-Jool;Jung, Ji-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.69-72
    • /
    • 2008
  • The local water contents and water transfer characteristics in the PEMFC system were investigated by numerical simulations and experiments. The performance of a lab-scale PEMFC is measured for fully humidified gases conditions and non-humidified ones. In order to observe the local water contents and water transfer characteristics inside PEMFC, the numerical simulation using CFD module on STAR-CD(es-pemfc) were conducted. The results show that the water content was increased as increasing current density, whereas it was decreased in high current density region. Then there was close correlation between high water content and internal temperature inside of MEA, and high current density was observed when internal temperature was dramatically increased.

  • PDF

PSCAD/EMTDC Model of PEMFC for Power System Analysis (전력계통 해석을 위한 PEMFC의 PSCAD/EMTDC 모델)

  • Lee, Jong-Su;Kim, Hak-Man;Lee, Byoung-Kuk;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • The modelling of PEMFC(Proton Exchange Membrane Fuel Cell) has been studied in many kinds of methods. But there are some limitations in application of the developed models to analyze transient phenomena of power systems. The PSCAD/EMTDC is very popular simulation tool in power system areas. To analyze power systems interconnected to PEMFCs, the PSCAD/EMTDC model of the PEMFCs is needed. In this paper, we developed a PSCAD/EMTDC model of PEMFC based on electro-chemical characteristic equations of PEMFC. Also, we performed simulations using the developed model in the PSCAD/EMTDC program and tested appropriateness of the proposed models. The simulations showed good results.

The thermal cycle degration of MEA in PEMFC under cold start condition (냉시동 환경에서 thermal cycle이 FEMFC의 MEA 열화에 미치는 영향)

  • Rhee, Jun-Kee;Seo, Dong-Ho;Jeon, Yu-Kwon;Shul, Yong-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.412-414
    • /
    • 2009
  • In recent times, starting up polymer electrolyte membrane fuel cells(PEMFC) in sub-zero condition is a great challenge of fuel cell electric vehicle(FCEV). The water produced in a cathode during PEMFCs operate. The water changes into the form of solid/ice in sub-zero temperatures and this makes trouble in PEMFC cells. Voltage of PEMFC drops and cold startup is failed. This paper describes an experimental study on the effect of thermal cycle to degradation of MEA in PEMFC.

  • PDF

Visualization of two-phae flow by using transparent Proton Exchange Membrane Fuel Cell (고분자 전해질 연료전지 가시화 장치를 이용한 이상유동 현상 관찰)

  • Lee, Dong-Ryul;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.374-377
    • /
    • 2009
  • The operating temperature of Proton Exchange Membrane Fuel Cell (PEMFC) usually has to be limited under $100^{\circ}C$ to maintain the proper ionic conductivity. Therefore, the only product from reaction, water, is in the liquid phase. Two-phase flow makes the flow phenomenon in the channel difficult to understand and predict. Water blocking in the PEMFC channel or the pore of Gas Diffusion Layer (GDL), called flooding, is known as the main effect of PEMFC degradation. To analyze two-phase flow, the PEMFC with transparent acrylic plate was used. Two-phase flow patterns were observed by varying the current density. When the PEMFC is mounted horizontally, water in the cathode is mainly transported on the interface between the channel and GDL.

  • PDF

Economic feasibility of 1kw household PEMFC System in Korea and Japan (한국과 일본에서의 가정용 PEMFC 시스템 경제성 분석)

  • Oh, Si-Doek;Kim, Ki-Young;Seo, Seok-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.105-108
    • /
    • 2007
  • Fuel cell with high electric efficiency has many probabilities of commercial use. Especially, proton exchange membrane fuel cell (PEMFC) which is a low temperature fuel cell and has less influence on $CO_2$ concentration is considered the power generation system of small building and household. We calculated the optimal operational plans of 1 kW household PEMFC power system based on the daily electricity and heat demand patterns of Japan and Korea. Calculated results show that the economic feasibility of PEMFC power system is very sensitive to the cost policy of electricity and natural gas.

  • PDF

Optimal Operational Planning of 1 kW Household PEMFC System (가정용 PEMFC 운전 최적 설계)

  • Kim, Ki-Young;Seo, Seok-Ho;Oh, Si-Doek;Kwak, Ho-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.113-116
    • /
    • 2007
  • The fuel cell which converts directly chemical energy of fuel into electric energy has higher efficiency than the conventional power generation which involves several additional processes. Especially, polymer electrolyte membrane fuel cell (PEMFC) of which the electrolyte is a thin proton conductive polymer membrane is affordable for portable power applications and small-scale distributed power generation including household and small building. It is very important to not only increase the efficiency of FC itself but determine the optimal operation mode. The optimal operational planning of lkW household PEMFC system based on the daily electricity and heat demand patterns was performed. The estimated economic gain was up to 20% by adoption of PEMFC system.

  • PDF

The development of membranes for high temperature PEMFC

  • Lee, Doo-Yeon;Sun, Hee-Young;Cho, Chung-Kun;Lee, Myung-Jin;Seung, Do-Young
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.184-184
    • /
    • 2006
  • We have succeeded in the preparation of high molecular weight polybenzimidazoles by solution polycondensation of 3,3'-diaminobenzidine tetrahydrochloride with isophthalic acid, terephthalic acid, or with their derivatives using polyphosphoric acid both as solvent and as condensing agent. Also, we modified phosphoric acid into fluoroalkyl-phosphonic acids[F-PA]. The main reasons are as follows, first of all F-PAs are stronger acids than PA and alkylphosphonic acids which should promote proton hopping and transport. In addition, F-PA has weaker adsorption onto Pt which help to prevent electrocatalyst poisoning and promote higher oxygen reduction activity. The ionic conductivity of 85%-H3PO4 doped membranes show $10^{-2}\;Scm^{-1}\;to\;3{\times}10^{-2}\;Scm^{-1}\;at\;150^{\circ}C$ MEA with 2 %-added electrolyte shows slightly higher cell voltage than the others.

  • PDF

A Dynamic Model of PEMFC for Residential Power Generator (가정용 연료전지 시스템 동특성 해석 모델)

  • Yu, Sang-Seok;Kim, Han-Seok;Lee, Sang-Min;Lee, Young-Duk;Ahn, Kook-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.12-16
    • /
    • 2007
  • A dynamic model of proton exchange membrane fuel cell(PEMFC) system is designed to understand the performance of the PEMFC in residential power generator(RPG) over various balance of plant(BOP) options. In particular, since the performance of PEMFC system should be optimized for given operating ranges, it is necessary to design suitable BDP components which can support the operating ranges. The objective of this study is to develop a dynamic system model for the study of PEMFC performance over various BOP options. Therefore, a dynamic model is composed of a PEMFC stack model, a water management system model, a thermal management system model and a fuel/air supply model and the model is integrated under SIMULINK(R)environment. Basic simulation results will be presented.

  • PDF

Cost Policy Effects of Economic Feasibility of 1kw household PEMFC System (요금 정책이 PEMFC 시스템 경제성에 미치는 영향)

  • Kim, Ki-Young;Hwang, Nam-Sun;Kong, Min-Seok;Kim, Hee-Su;Oh, Si-Doek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.31-34
    • /
    • 2007
  • Fuel cell with high electric efficiency has many probabilities of commercial use. Especially, polymer electrolyte or proton exchange membrane fuel cell (PEMFC) which is a low operating temperature and has less influence on $CO_2$ concentration is considered the power generation system of small building and household. We calculated the optimal operational plans of 1 kW household PEMFC power system based on daily electric and heat demand patterns of various size of apartments. Calculated results show that the economic feasibility of PEMFC power system is very sensitive to the cost policy of electricity and natural gas.

  • PDF

Characteristics of 5 kW Class Proton-Exchange-Membrane Fuel Cell(PEMFC) Stack according to the Long-Term Operation (장기운전에 따른 5 kW급 고분자 전해질 연료전지 스택의 특성)

  • Kim, Jae-Dong;Lee, Jung-Woon;Park, Dal-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.40-43
    • /
    • 2007
  • The performance of PEMFC stack can be improved significantly by optimizing the design and operating conditions. As a result, the performance of daily operation showed slight deviation (0.02-0.9%) after accumulated DSS operation for 500 hrs but the stack performance was stable. Therefore, it is confirmed that it would be improved the life-time of stack and operation reliability for the commercialization of PEMFC system.

  • PDF