• 제목/요약/키워드: PIV

검색결과 1,397건 처리시간 0.028초

Dual-plane Stereoscopic PIV Measurement on the Lobed Jet Mixing Flow

  • SAGA Tetsuo;KOBAYASHI Toshio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.108-122
    • /
    • 2001
  • In a continuing effect to study the mixmg enhancement by large-scale streamwise vortices in lobed mixing flows, an advanced PIV system named as dual-plane stereoscopic PIV system was used in the present study to conduct simultaneous vorticity (all three components) measurement of an air jet exhausted from a lobed nozzle. Unlike 'classical' 2-D PIV system or conventional 'single-plane' stereoscopic PIV system, the dual-plane stereoscopic PIV system used in the present study can obtain the flow velocity (all three components) fields at two spatially separated planes simultaneously. Therefore, it can provide the distributions of all the three components of vorticity vectors instantaneously and simultaneously. The evolution and interaction characteristics of the large-scale streamwise vortices and azimuthal Kelvin-Helmholtz vortices in the lobed jet mixing flow were revealed instantaneously and quantitatively from the measurement results of the dual-plane stereoscopic PIV system. The characteristics of the mixing process in the lobed jet mixing flow were analyzed based on the simultaneous measurement results of the steamwise vorticity and azimuthal Kelvin-Helmholtz vorticity distributions.

  • PDF

PIV를 사용한 2차원 원형 실린더 주위의 유동해석 (Flow Survey around Two-Dimensional Circular Cylinder using PIV Technique)

  • 박건선;곽영기
    • 한국해양공학회지
    • /
    • 제18권3호
    • /
    • pp.1-7
    • /
    • 2004
  • Flaw visualization and velocity field measurement methods have practical applications in the various fluid engineering fields, such as mechanics, ships, and heat fluids. In this study, the basic principles and theoretical methods are used to establish an application technique of Particle Imae Velocimetry(abbreviated to PIV below). Accordingly, the measured results of velocity field distribution of a section inside the Circulating Water Channel (abbreviated to CWC below) are computed using the PIV is presented. The uniformity of velocity distribution of the section in CWC is confirmed, by comparing this PIV data with the existing current meter data. Also, in order to measure the flaw fields of surroundings of 2-dimensional cylinder in the CWC, the flaw visualization technique using the PIV is applied.

Angiographic PIV기법 개발 및 성능 평가 (Development of angiographic PIV and performance evaluation)

  • 정성용;김국배;임남윤;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.683-686
    • /
    • 2008
  • To diagnose vascular diseases from the viewpoint of hemodynamics, detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond were required. For investigating the hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique consisted of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulse-type X-ray source, and a synchronizer. Through several preliminary tests, the feasibility of the angiographic PIV technique was verified. For in-vivo measurements to real blood flows, we developed tracer microcapsules which were optimized to this system by encapsulating a contrast material of iodine with a matrix material of PVA (polyvinylpyrrolidone). In near future, the angiographic PIV technique would be useful for diagnosing hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

초음파 조영제를 애용한 Echo PIV 기법의 개발 (Development of Echo PIV Using Ultrasound Contrast Agent)

  • 김형범
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

PIV데이터의 post-processing에 의한 애니메이션 제작 및 적용예 (Animation construction and application example by the post-processing of PIV data)

  • 김미영;최장운;이현;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.655-660
    • /
    • 2000
  • Animation technique from the PIV database is particularly emphasized to give macroscopic and quantitative description of complex flow fields. This paper shows animation construction and application example for the post-processing of PIV data. As examples, first case is a pitching airfoil immersed in tree surface water circulating tunnel. Second case is a wake of a model-ship. Third case of PIV data is a large scale surface flow field. Obtained images are processed in time sequence by PIV exclusive routines where an efficient and reliable cross correlation algorithm is included for vector identification. All. animation Jobs are implemented completely on single personal computer environment. Compressed digital images are obtained initially by Motion-JPEG board and various An files are finally obtained through graphic processes.

  • PDF

미세 생체유동 해석을 위한 첨단 유동가시화기법 (Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows)

  • 이상준
    • 대한기계학회논문집B
    • /
    • 제33권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

파노라마-PIV를 이용한 실내기류 해석 (Analysis of Airflows in a Room with Panoramic PIV)

  • 황태규;도덕희
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1154-1160
    • /
    • 2005
  • A panoramic-PIV system has been constructed for the analysis of the airflows in a room. Smoke is used as seeding particles and are visualized by a pulsed laser (Nd-Yag, 120 mJ). Panoramic images have been obtained by an image composition process using the two images obtained by the two cameras $(1k\times1k)$ that are viewing the wide measurement areas. Velocity vector fields have been obtained by the grey-level cross-correlation PIV method. Three room models $(L{\times}W{\times}H[mm^3],\;500\times500\times250,\;350\times350\times175,\;250\times250\times125)$ have been tested. The experimental results have proven that the constructed panoramic-PIV system can be used as a useful tool for analyzing the airflow characteristics in the room models.

PIV의 성능개선에 관한 연구 (A Study on the Improvement of PIV Performance)

  • 이영호;김춘식;최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.34-42
    • /
    • 1994
  • The present study is aimed to improve the PIV performance by suggesting a two-frame particle identification technique and by introducing estimation method of wall pressure distribution from the velocity data. Adopted image processing system consists of one commercial image board slit into a personal computer, 2-D sheet light generator, flow picture recording apparatus and related particle identification software. A revised particle tracking method essential to PIV performance is obtained by particle centroid correlation pairing (CCP) and its effectiveness is ascertained by comparison with multi-frame identification.

  • PDF

Evaluation on the Performance of Deep Excavation by Using PIV Technique

  • Abbas, Qaisar;Song, Ju-sang;Yoo, Chung-Sik
    • 한국지반신소재학회논문집
    • /
    • 제16권4호
    • /
    • pp.191-210
    • /
    • 2017
  • The concern study, present the results of experimental study on the performance of deep excavation by using image processing technique particle image velocimetry (PIV). The purpose of present study is to check the application of PIV for the successive ground deformation during deep excavation. To meet the objectives of concern study, a series of reduce scale model test box experiments are performed by considering the wall stiffness, ground water table effect and ground relative density. The results are presented in form of contour and vector plots and further based on PIV analysis wall and ground displacement profile are drawn. The results of present study, indicate that, the PIV technique is useful to demonstrate the ground deformation zone during the successive ground excavation as the degree of accuracy in PIV analysis and measured results with LVDT are within 1%. Further the vector and contours plot effectively demonstrate the ground behavior under different conditions and the PIV analysis results fully support the measured results.

X-ray PIV 기법의 개발과 적용연구 (Development of X-ray PIV Technique and Its Applications)

  • 이상준;김국배;김석;김양민
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.20-25
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed fur measuring quantitative information on flows inside opaque conduits and/or opaque-fluid flows. To check the performance of the x-ray PIV technique developed, it was applied to a liquid flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, the refraction-based edge enhancement mechanism was employed with seeding detectable tracer particles. The amassed velocity field data obtained were in a reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to get velocity fields of blood flow and to measure size and velocity of micro-bubbles simultaneously, and to visualize the water refilling process in bamboo leaves. The x-ray PIV was found to be a powerful transmission-type flow imaging technique fur measuring quantitative information of flows inside opaque objects and various opaque-fluid flows.

  • PDF