• Title/Summary/Keyword: PIV

Search Result 1,397, Processing Time 0.024 seconds

PIV Measurements of the Pressure Driven Flow Inside a T-Shaped Microchannel (T형 마이크로채널 내부 압력구동 유동의 PIV 계측)

  • Choi Jayho;Lee In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.423-426
    • /
    • 2002
  • A custom micro-PIV optics assembly has been used to measure the flow field inside a T-shaped microchannel. The micro-PIV system consists of microscope objectives of various magnifications, a dichroic cube, and an 8-bit CCD camera. Fluorescent particles of diameters 620nm have been used with a Nd:YAG laser and color filters. A programmable syringe pump with Teflon tubings were used to inject particle-seeded distilled water into the channel at flow rates of $420,\;40,\;60{\mu}L/hr$. The microchannels are fabricated with PDMS with a silicon mold, then $O_2-ion$ bonded onto a slide glass. Results show differences in flow characteristics and resolution according to fluid injection rates, and magnifications, respectively. The results show PIV results with vector-to-vector distances of $2{\mu}m$ with 32 pixel-square interrogation windows at $50{\%}$ overlap.

  • PDF

PIV measurements of a microfluidic elements fabricated in a plastic chip (플라스틱 미소유체요소 내부유동의 PIV 측정)

  • Lee, In-Won;Choi, Jay-Ho;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.400-404
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.7\times6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

An Experimental Investigation on Flow Field in a Pipe with Sinusoidally Wavy Surface by PIV (PIV를 이용한 3차원 파형관 내부 유동장의 실험적 연구)

  • 김성균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.368-373
    • /
    • 2004
  • A flow field in a passage with periodically converging-diverging cross-section is investigated experimentally by PIV measurement. A tube with a sinusoidally wavy cross section is one of several devices employed for enhancing the heat and mass transfer efficiency due to turbulence promotion and unsteady vortical motion. While the numerical flow visualization results have been limited to the fully developed cases, existing experimental results of this flow were simple qualitative ones by smoke or dye streak test. Therefore, the main purpose of this study is to produce quantitative flow data for fully developed and transient flow regime by the Correlation Based Correction PIV (CBC PIV) and to conjecture the analogy between flow characteristics and heat transfer enhancement with low pumping power. Another purpose of this paper is to examine the onset position of the transition and the global mixing, which results in transfer enhancement. At Re=2000, evidences of the global mixing are captured at 2.5 wavy module through the variation of RMS values and instantaneous velocity plot.

Precise Estimations on Vorticities using a Hybrid PTV-PIV Algorithm (하이브리드 PTV-PIV알고리듬에 의한 고정밀 와도 추정)

  • Doh, Deog-Hee;Cho, Gyong-Rae;Lee, Jae-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.26-30
    • /
    • 2010
  • A PTV algorithm was constructed using a linear transformation, in which the merits of the conventional PIV and PTV were adopted. In PIV calculations, the obtained velocity vectors are affected by the filtering effects by its calculation principle. PTV techniques are widely used for their excellences of measuring small scaled flows, such as nano and bio flows. However, PTVs produce vector errors due to interpolation process. To overcome these problems, a hybrid PTV algorithm was constructed by combining PTVs' and PIVs' benefits using a linear transformation. The Taylor-Green vortex flows were generated for the tests of vorticity calculations. The conventional gray-level cross-correlation PIV technique and 2-Frame PTV technique were tested for the same flows for comparisons with those obtained by the constructed hybrid algorithm. The excellence of the constructed hybrid algorithm was validated through an actual experiment on the cylinder wake.

Advanced Flow Visualization Technologies and Blue Ocean Strategy (첨단 유동가시화 기법들과 Blue Ocean 전략)

  • Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.3-5
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, aynni.c PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced mea-surement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. They would be indispensable in solving complicated thermo-fluid flow problems not only in industrial fields such as automotive, space, electronics, aero- and hydro-dynamics. steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy technology etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe the nano- and bio-fluidic flow phenomena. In this article, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body are introduced as a blue ocean strategy.

  • PDF

Measurement of the Velocity Field of Rotor-Stator in a Centrifugal Turbine Pump Using PIV (PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측)

  • Im, Yu-Cheong;Seo, Min-Sik;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.35-42
    • /
    • 1999
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stater region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

Flow Characteristics around a NACA0012 Airfoil by PIV (PIV에 의한 NACA0012 익 주변의 유동특성)

  • Choi, M.S.;Cho, D.H.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.1
    • /
    • pp.29-37
    • /
    • 1999
  • The flow characteristics of a NACA0012 airfoil was investigated in rectangular water circulating channel. The flow patterns around an airfoil at various angles of attack between $0^{\circ}\;and\;30^{\circ}\;at\;Re=1.91{\times}104$ were visualized and measured with 2-D PIV system and laser sheet illumination. Flow behaviors such as velocity distribution, kinetic energy and flow separation etc. around an airfoil were obtained by means of 2-D PIV system. The behaviors show the difference of flow pattern clearly and separation phenomena become more active with increasing angle of attack.

  • PDF

A Study on the Evaluation of Interpolation Methods in PIV (PIV에서의 보간기법의 평가에 관한 연구)

  • 최장운;조대한;최민선;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.90-100
    • /
    • 1996
  • To maintain high spacial accuracy and rapid CPU time in interpolating data from grid to random position or inversely in PIV, proposed many technuques are compared and discussed mainly in terms of interpolating error and computing time. And artificial PIV atmosphere data is furnished by CFD result. First, for interpolation from grid to random position, multiquadric method gives the highest accuracy with the longest CPU time and Taylor series expansion methods give reasonable accuracy with less calculating load. Secondly, the sub-pixel resolution analysis in estimating the coordinates of the maximum correlation coefficients essential in the grey level correlation PIV reveal that 8-neighbours 2nd-order least square interpolation gives utmost accuracy in terms of the real flow conditions.

  • PDF

A Study on the Evaluation of Interpolation Methods in PIV (PIV에서의 보간기법의 평가에 관한 연구)

  • Choi, J.W;Cho, D.H;Choi, M.S;Lee, Y.H
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.412-412
    • /
    • 1996
  • To maintain high spacial accuracy and rapid CPU time in interpolating data from grid to random position or inversely in PIV, proposed many technuques are compared and discussed mainly in terms of interpolating error and computing time. And artificial PIV atmosphere data is furnished by CFD result. First, for interpolation from grid to random position, multiquadric method gives the highest accuracy with the longest CPU time and Taylor series expansion methods give reasonable accuracy with less calculating load. Secondly, the sub-pixel resolution analysis in estimating the coordinates of the maximum correlation coefficients essential in the grey level correlation PIV reveal that 8-neighbours 2nd-order least square interpolation gives utmost accuracy in terms of the real flow conditions.

Measurement of Flow Field in a Domestic Hot-Water Pump by PIV (PIV에 의한 가정용 온수펌프의 유동장 계측)

  • Lee, H.;Im, Y. C.;Kim, J. H.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF