• Title/Summary/Keyword: PIV

Search Result 1,397, Processing Time 0.034 seconds

Real time measurement of an acoustic stream by a visualization technique, PIV (PIV(Particle Imaging Velocimetry)에 의한 음향류의 실시간 가시화 계측)

  • 도덕희
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.239-242
    • /
    • 1998
  • A new real time sound field visualization technique is introduced in this study using PIV(Particle Imaging Velocimetry) technique. Small particles of which density is small enough to follow up the air flow are used for sound visualization. When the driving frequency is in the vicinity of the resonance frequency of the simplified 2-dimensional muffler system, an acoustic streaming is shown and of which velocity distribution is obtained through PIV technique. It is experimentally proved that the present technique is able to visualize and quantify the sound field's energy flow.

  • PDF

A Study on Flow Characteristics of a Ginseng Cleaner Using PIV (PIV에 의한 인삼세척기의 특성연구)

  • 송치성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.140-145
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15.20 27ℓ/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous velocity distribution time0mean velocity distribution and velocity profile are represented quantitatively for the deeper understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

A Quantitative Visualization of Mixed Convection in Parallel Plates Using PIV (PIV를 이용한 평행평판 내의 혼합대류의 정량적 가시화)

  • 박일용;배대석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.509-515
    • /
    • 2004
  • The PIV(Particle Image Velocimetry) with liquid crystal tracers is used for visualizing and analysis of the mixed convection in the parallel plates with the upper part cooled and the lower part heated. It is found that the flow pattern of mixed convection in the parallel plates can be classified into three patterns which was affected by Reynolds number. Also, the periodic nature is confirmed, and visualized in experiment.

A Study on Development of Commercial PIV Utilizing Multimedia (멀티미디어 대응 상용 PIV의 국산화개발에 관한 연구)

  • 최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.5
    • /
    • pp.652-659
    • /
    • 1998
  • The present study is aimed to develop a new PIV operating software through optimization of vector tracking identification including versatile pre-processings and post-processing techniques. And the result exhibits an improved version corresponding various input and output multimedia compared to previous commercial software developed by other makers. An upgraded identification method called grey-level cross correlation coefficient method by direct calculation is suggested and related user-friendly pop-up menu are also represented. Post-processings comprising turbulence statistics are also introduced with graphic output functions.

  • PDF

PIV Measurement and Flow Characteristics of Internal Flow Field within Ginseng Washing Machine (인삼세척기 내부유동장의 PIV계측 및 유동특성)

  • Na, Eun-Su;Song, Chi-Seong
    • 연구논문집
    • /
    • s.30
    • /
    • pp.59-65
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry)to high_speed flow characteristics within Ginseng washing machine. Three different kinds of flow rate(15,20,27 $\ell$/min)are selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Instantaneous velocity distribution, time-mean velocity distribution and velocity profiles are represented quantitatively at the full-scale region for the deeper understanding of the flow characteristics in Ginseng washing machine.

  • PDF

A Study on Biased Flow Region Using PIV Technique (PIV기법을 이용한 편향흐름 발생영역 규명)

  • Na, Jeong-Heon;Kwon, Sun-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.105-112
    • /
    • 1999
  • This research is an experimental investigation of the region of the Biased Flow. This experiment was carried out in a circulating water channel, and the results are analyzed by using the PIV technique. The results are presented in velocity vector field, velocity contour and vorticity contour. The results were compared with those of Zdravkovich which were carried out in a wind tunnel. These results will be very useful to verify numerical codes.

  • PDF

Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation (CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석)

  • Ha, Jung-Soo;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

Hybrid Particle Image Velocimetry Based on Affine Transformation (어파인변환 기반 하이브리드 PIV)

  • Doh, Deog-Hee;Cho, Gyong-Rae;Lee, Jae-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.603-608
    • /
    • 2011
  • Since PTV (particle tracking velocimetry) provides velocity vectors by tracking each particle in a fluid flow, it has significant benefits when used for nano- and bio-fluid flows. However, PTV has only been used for limited flow fields because interpolation data loss is inevitable in PTV in principle. In this paper, a hybrid particle image velocimetry (PIV) algorithm that eliminates interpolation data loss was constructed by using an affine transformation. For the evaluation of the performance of the constructed hybrid PIV algorithm, an artificial image test was performed using Green-Taylor vortex data. The constructed algorithm was tested on experimental images of the wake flow (Re = 5,300) of a rectangular body ($6cm\;{\times}3cm$), and was demonstrated to provide excellent results.

Flow Visualization of Arteriovenous Grafting Using PIV Technique (PIV 기법을 이용한 동정맥루 문합에 대한 유동가시화)

  • Jeon, Min-Gyu;Kim, Hyoung-Ho;Suh, Sang-Ho;Choi, Young Ho;Lee, Hyun-Jin;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.985-990
    • /
    • 2013
  • An arteriovenous fistula is artificially produced using a graft for hemodialysis in patients. In an arteriovenous graft (AVG), the angle of its arterial or venous anastomosis play an important role in producing flows inside blood vessels, through which a stenosis may occur. Most studies thus far have focused on CFD results. In this study, a PIV technique is used to analyze the hemodynamic characteristics at the arterial or venous anastomosis of an AVG having an angle of $30^{\circ}C$. For flow dynamic similarity, the Reynolds number is set to be the same for real and simulated flows. A PIV experiment is performed with a control valve in the arterial part. In conclusion, the recirculation flow appeared in the bifurcation area and the total blood velocity changed according to the extent of valve opening.

Comparison of Swirl Ratio Measured by Impulse Swirl Meter and Particle Image Velocimetry in a Steady Flow Bench of SI Engine (SI 엔진의 정상유동장치에서 충격식 스월미터와 입자영상유속계의 스월비 측정에 대한 비교 연구)

  • Lee, Sukjong;Ohm, In Yong;Sung, Jaeyong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.437-442
    • /
    • 2015
  • The swirl ratio in a SI engine is investigated in a steady flow bench according to the measurement methods: an impulse swirl meter and particle image velocimetry (PIV). When measuring the swirl ratio using the PIV, the torque is evaluated based on the cylinder center and swirl center, respectively. The position of the measurement plane is considered. As a result, in the upstream, the swirl ratio measured by the impulse swirl meter is estimated to be larger than that from the PIV measurements due to the unstable vortex motions. Regarding the PIV measurements, the swirl ratio based on the cylinder center has been found to be lower than that based on the swirl center. On the other hand, the difference in swirl ratio has decreased smaller as the measurement plane moved downstream due to the stabilization of the vortex motion.