• Title/Summary/Keyword: Pack ice

Search Result 63, Processing Time 0.026 seconds

Effects of an ice pack and sulfur generating pad treatment for home delivery on the quality of 'Duke' blueberry fruits

  • Lim, Byung-Seon;Choi, Mi-Hee;Lee, Jin-Su
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.4
    • /
    • pp.811-821
    • /
    • 2018
  • This study focused on the improvement of blueberry delivery service using pre-cooled ice and $SO_2$ pads to prevent an increase in the fruit temperature as well as decay. To maintain the fruit quality during low temperature storage, the effect of a $SO_2$ pad and modified atmosphere packaging was also examined. Harvested blueberries were precooled at $15^{\circ}C$, sorted, and packaged. And the fruits were placed in a similar environment as that for the parcel service. Part of the fruits were stored at $0^{\circ}C$ for long term storage. The air temperature in the delivery box increased along with an increase in the simulated delivery time regardless of the treatment. However, the rate of temperature increase was lower in the ice pad treatment. No significant difference was not found after 48 h. The oxygen concentration in the box ranged between 10.5 - 14.5% in the ice pad treatment, which was higher than that of the untreated control (7.5 - 11.9%) whereas the $CO_2$ concentration was lower in the ice pad treatment. No differences were found in the occurrence of off-flavor, decay, and sensory quality loss during the 48 hours of the parcel service simulation. The combined treatment of the $SO_2$ pad and modified atmosphere packaging (MAP) using a perforated film increased the shelf-life of the blueberry fruits, the overall quality such as firmness, and the soluble solid content was not different between the treatments except for the decay incidence. No decayed fruit was found in the combined treatment. However, the percentage of decayed fruit in the control was 25% on day 15 of storage and 75% on day 33 of storage, respectively.

A Literatural Study on the Evidence of Using Thermotherapy and Cryotherapy of Cutaneous and Muscle Meridian in Korean Medical Physiotherapy (한방이학요법 중 경피경근온냉요법에 대한 문헌적 고찰)

  • Choi, Bo-Mi;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.73-81
    • /
    • 2010
  • Objectives : The purpose of this study is to establish literatural evidence about thermotherapy and cryotherapy for Korean medicine through literatural review. Methods : Applicable paragraphs which were related to the thermotherapy and cryotherapy of cutaneous and muscle meridian were phrased from in "Yibujicheng(醫部集成) and "Dongyibaojian(東醫寶鑑)" where were archiving of Oriental or Korean medicine literatures. Searched paragraphs were analysed for establishing historical and theoretical bases of thermotherapy and cryotherapy in Korean medicine. Results : Thermotherapy of cutaneous and muscle meridian(經皮經筋溫熱療法) such as hot pack, warm water therapy, paraffin bath, ultrasound is originated from yu(慰) warm water(溫水) hot water(熱水). Matching indications are various pain conditions(caused by coldness(寒), hard-work(僗若), extravasated blood(瘀血), inflammatory skin disease, frostbite and several internal diseases. It also treats gynecological diseases and facial palsy. Diathermic therapy on acupuncture points(穴位照射溫熱療法) such as infra-red, microwave, shortwave is originated from huolu(火爐), wenlu(溫爐), xianglu(香爐), lamp light(燈火). Its objective is to improve the effects of herb medicine by aiding sweating or to treat the residual symptoms of fever disease or to care skin disease and pain from bone fracture, contusion. Cryotherapy of cutaneous and muscle meridian(經皮經筋溫寒冷療法) such as ice pack, ice spray, iced whirpool, cool water bath is originated from lengfu(冷敷), lengtie(冷貼), lengshiyu(冷石熨). Matching indications are contusions, animal bite injury, corn(肉刺) and (淋病), eye disease, nasal bleeding, hemorrhoid, inflammatory skin disease and chicken pox. Conclusions : Thermotherapy and cryotherapy of cutaneous and muscle meridian(經皮經筋溫冷療法) are the treatments which were used in Korean medicine from the ancient Korean medicine. As scientific equipments were originated from yu(慰), huolu(火爐), wenlu(溫爐), xianglu(香爐), lamp light(燈火). lengfu(冷敷), lengtie(冷貼), lengshiyu(冷石熨). It can be said that these are elements of Korean medicine. More rigorous studies are needed to establish clinical evidence about not only thermotherapy and cryotherapy but also the other physiotherapy of Korean medicine.

Analysis of the Effects and Nursing Intervention of Home Health Care in Public Health Centers (보건소 방문보건사업 효과와 간호중재 분석)

  • Chin, Young-Ran;Chang, Hyun-Sook;Lee, In-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.3
    • /
    • pp.353-364
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the types and frequencies of nursing intervention of home health care in Public Health Centers and its effects. Method: The data collection period for this study lasted from March 1 to December 31, 2003. The clients were sampled by a stratified randomized method among those who had been cared for at least 3 months. The data was analyzed by SPSS for description. ANOVA, paired t test, etc. Result: The types and frequencies of nursing intervention in major chronic health problems were significantly different. The main types of nursing intervention in hypertension and DM patients included education on disease management, regular exercise, stress management, diets, etc. CVA patients were intervened in pain control (ice or hot pack, massage), position changes, and ROM exercise. Cancer patients received imaginary or relaxation therapy, pain control (ice or hot pack, massage), hospice, etc. After the intervention, the drug compliance of hypertension (8.2 days per month) and DM patients (6.2 days per month) improved. Blood sugar levels (FBS 7.6, post partum 2hrs $21.4(mg/d{\ell})$ and blood pressure(systolic 9.8, diastolic 4.3 mmHg) lowered significantly. All aspects of QOL also improved (total 3.68). Conclusion: The types and frequencies of nursing intervention were determined by characteristics of the health problems, and home health care nursing intervention in Public Health Centers was effective to the elderly of the community in many aspects.

  • PDF

Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position (측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석)

  • Lee, Chungkeun;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

Effect of a Therapeutic Exercise Program on the Functional Recovery Following Temporomandibular Joint Surgery (측두하악관절 수술 후 관절 운동프로그램이 기능회복에 미치는 영향)

  • Oh, Duck-Won;Kim, Ki-Song;Lee, Gyu-Wan;Jung, Nak-Su
    • Physical Therapy Korea
    • /
    • v.6 no.3
    • /
    • pp.94-109
    • /
    • 1999
  • The purposes of this study were to assess the effect of therapeutic exercise and to offer an approach to the physical therapy and rehabilitation procedure of the temporomandibular joint (TMJ) following surgery. In this research, 42 patients with TMJ surgery were assigned one of two groups. The experimental group included 21 patients who performed therapeutic exercise, and the control group included 21 patients who did not perform therapeutic exercise. Conservative therapy such as an ice pack, a hot pack, and pulsed ultrasound was applied to both groups. Treatment was applied twice a day during the admission period and, after discharge, everyday for six weeks. Visual analogue scale (VAS), incisal biting force, and joint ROM were measured before surgery and at 30 days after surgery. The results were as follows: VAS (p<0.05), mouth opening (p<0.01), lateral excursion to unaffected side (p<0.05), and protrusion (p<0.05) between experimental group and control group showed statistically significant differences. Incisal biting force and lateral excursion to affected side between experimental group and control group showed no statistically significant difference.

  • PDF

Prevention Technologies of environmental contamination and IMO action in Arctic Ice-covered Waters (극지해역에서의 환경오염 방지 기술 및 IMO 동향)

  • Kang, Jae-Sung;Kim, Ki-Pyoung;Kang, Ho-Keun;Kim, Dae-Heon
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.237-239
    • /
    • 2011
  • 최근 국제해사기구(International Maritime Organization, IMO)는 "극지를 운항하는 선박에 대한 안전기준(Polar Code)"를 제정하여 결정하기로 하였으며, 2012년까지 완료하여 법제화하기로 하였다. 이는 최근의 극해 지역의 연속적인 사고의 심각성에 대한 대비책의 일환이다. 2004년도에 알라스카 앞바다에 침몰한 Selendang Ayu 는 6600만 톤의 콩, 170만 리터의 연료유와 55,564 리터의 MDO 및 다른 오염물질을 바다에 유출하였다. 이는 주변의 동물들에게 심각한 영향을 끼쳤고, 아직까지도 유출되어진 오염물질들을 완전히 처리하지 못한 상태이다(Arctic marine shipping assessment, Arctic council 2009.). 즉, 기름이 유출을 하면 방재시설이 다른 육상에서 오기 전까지는 상당히 오랜 시간 동안, 사고 지역 주변을 오염시키게 되며, 유빙이나 극한의 온도는 방재 작업을 더욱 힘들게 한다. 본 연구에서는 극해와 같은 해역에서 기름이 유출 하였을 때에 대응하는 방법, 즉 현존하는 기계적인 복구 방식, 점화식 처리 방식 과 유처리제 방식을 소개하고, 그에 대한 국제규정 및 기술 발전 동향에 대해서도 설명한다.

  • PDF

Riboflavin in milk and milk products and the destructive effect of sunlight (우유(牛乳)와 유제품(乳製品)의 Riboflavin 함량(含量) 및 일광(日光) 노출시의 파괴율에 관한 연구)

  • Paik, Jeong-Ja;Kim, Harriet
    • Journal of Nutrition and Health
    • /
    • v.9 no.2
    • /
    • pp.54-58
    • /
    • 1976
  • Inadequacy of riboflavin intake among Koreans had been pointed out repeatedly in most dietary and nutritional surveys in Korea. The consumption rate of dairy products has been increasing markedly in recent years. Milk and milk products are known to be a good source of the vitamin which can easily be destroyed by the sunlight. Total riboflavin content of the pasteurized and homogenized milk, both plain and flavored, and the milk products were measured by the Lumiflavin method. It ranged from $62.4{\mu}g$ riboflavin per 100g of homogenized milk to $195.9{\mu}g$ for vanilla flavored ice cream. In general milk products in the form of cream contained about three times as much riboflavin as plain milk. The rates of destruction of riboflavin in chocolate milk and white milk in clear glass bottle and in polyethylene pack were different when measured in 30 min intervals after exposure to bright sunlight for two hours. In the case of the plain milk, the riboflavin content decreased rapidly and remained only about a quarter of the initial value within an hour of the exposure period. The destruction rate slowed down after the first hour of the exposure and resulted about 90% destruction of riboflavin in two hours. The chocolate milk however exhibited a protective effects of the riboflavin from the sunlight. It retained 65% of the initial riboflavin after an hour of the exposure to sun and 55% ofter two hours. Two most widely used milk containers, clear glass bottle and polyethylene pack were about equally affected by the sunlight.

  • PDF

Multi-module Equalizer Circuit for Series-Connected Li-ion Batteries

  • Shin, Jong-Won;Seo, Gab-Su;Kim, Jong-Hoon;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.420-421
    • /
    • 2010
  • In this paper, a multi-module selective battery equalizer for series-connected Li-ion battery pack is proposed. Selective Equalizer (SE) scheme achieves smaller volume and lighter weight than individual cell equalizer (ICE) by minimizing the part count of bulky circuit element. However, SE scheme shows slow balancing speed when the voltage imbalance simultaneously occurs in more than one cell. The proposed multi-module overcomes the problem by employing multiple power converters. Prototype hardware is implemented and experimented with 14Ah battery cells to validate the performance of the proposed equalizer.

  • PDF

Comparison of Emergency Experience and First Aid Knowledge, Emergency Coping Ability of Elderly Care Facilities and Group Home Caregivers (노인요양시설과 노인요양공동생활가정 요양보호사의 응급상황 경험 및 응급지식, 응급상황대처능력 비교)

  • Kim, Soon-Ock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.239-253
    • /
    • 2020
  • This study is a descriptive research that provides basic data to develop customized emergency education programs for strengthening the emergency coping ability of facility and group home caregivers. Data were collected from 7.10~8.15 in 2020 in the S and G areas. A total of 236 questionnaires were included for the analysis. Data were analyzed using χ2, t-test, ANOVA, and Pearson's correlation coefficients. Approximately 68.9% facilities and 50.7% group homes experienced emergencies, and there was a significant difference (χ2=8.42, p=0.004). First aid personnel were nurses (nurse aides) 55.3% facility and 42.7% of facility directors group home, showing differences (χ2=27.84, p<.001). 56.5% and 68.0% in the facility and group home, first aid care : ice pack, medication, Heimrich in the facility and 119 and guardian call, ice pack, Heimrich for the group home. First aid knowledge was determined to be significantly different between the facilities (11.60±2.09) and group homes (9.08±2.28) (t=8.39, p<0.001). Similarly, the emergency coping abilities showed a significant difference (t=8.00, p<0.001) between facilities (52.94±5.27) and group homes (47.33±4.39). In addition, a positive correlation was established between the experience of emergency situations and the emergency coping ability in the facilities. Overall, our data indicates that the emergency experience, emergency knowledge, and emergency coping abilities of the facility and group home caregivers are significantly different. We propose that emergency education tailored to the characteristics of each institution is needed.

A Comparative Study on Heat Transfer Characteristics in Tissue Model with Application of Heating or Cooling Therapeutic Modalities (조직모델에서 냉.온치료기의 열전달 특성 비교 연구)

  • Kim, Yu Jong;Shin, Kyung Min;Kim, Eun Jung;Kim, Kyung Ho;Kim, Kap Sung;Lee, Seung Deok
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.125-138
    • /
    • 2013
  • Objectives : This study aimed to investigate temperature characteristics by heat transfer type of therapeutic modalities. Methods : We selected heating and cooling modalities that are frequently used in clinical by heat transfer type: conduction, convection, radiation, and conversion. We used ham as tissue model, and applied the modalities for 30 minutes. We measured real-time changed temperature($^{\circ}C$) of the surface, 2, 4, 6, 8, 10, 12, and 14 mm depth. Results : 1. In conduction-using hot pack, ice pack, and CryoStamp heating-cooling combination therapy unit($40^{\circ}C/{\sim}15^{\circ}C$), the surface temperature sharply rose close to equilibrium in first 5 minutes. 2. In convection-using smokeless moxa, temperature slowly rose to the maximum at 25-minute elapsed time. But in another convection-using CRAiS cryotherapy device, result was similar to that of conduction. 3. In radiation-using infrared lamp, result was similar to that of conduction, but not reached equilibrium during applying time. 4. In conversion-using ultrasound device, temperature was the highest at 6 mm depth, and not reached equilibrium during applying time. Conclusions : We could comprehend temperature characteristics and proper use of modalities by heat transfer type. It would be necessary to consider in vivo physical conditions in further studies.