• Title/Summary/Keyword: Package air conditioner

Search Result 21, Processing Time 0.023 seconds

Study on the Development for Low Noise Indoor Unit Package Air-Conditioner (저소음 패키지형 공기조화기의 실내기 개발에 관한 연구)

  • 이재효;조성철;김태헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.518-523
    • /
    • 2003
  • The purpose of this study was to reduce the noise emitted from the package air-conditioner. The optimum design methods of the fans ware investigated experimentally through the analysis of noise problem caused by the conventional PAC system. New PAC system had decreased 6 dBA in overall noise level as compared with the conventional system by various technology.

The Design of the Motor Bracket for Reduction of Structure-Borne Noise in Package Air-Conditioner (에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계)

  • Sim, Hyoun-Jin;Kim, Seong-Hyeon;Kang, Tae-Ho;Lee, Jung-Yoon;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.453-456
    • /
    • 2005
  • In recent years, the demand of a silent indoor air-conditioner is the essential research filed when the product is developed. In this study, through the design modification of the noise and vibration source, the noise and vibration level of the package air-conditioner is reduced. The modal analysis of the motor bracket is performed by FEM. To find the most suitable shape of the motor bracket, Design of Experiments is applied.

  • PDF

Estimation of the Noise Caused by the System Air Conditioner and its Improvement (시스템 에어컨에 의한 실내 소음 평가 및 개선 설계)

  • Lee, Jea-Won;Joo, Jae-Man;Oh, Sang-Kyong;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF

Optimum Design of an Indoor Package Air-Conditioner's Flow Path by Taguchi Method (다구찌 방법에 의한 PAC 실내기 유로의 최적설계)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 2014
  • In this study, the optimum design process of an indoor package air-conditioner (PAC) was implemented by Taguchi method. The goal of this study is to obtain the best set condition of each control factor composing of an indoor PAC. The number of revolution of a double inlet sirocco fan installed in an indoor PAC was measured by the orthogonal array of $L_{18}(2^3{\times}3^4)$ and analysed by using the-smaller- the-better characteristic among the static characteristic analyses. As a result, the optimum condition of an indoor PAC was found as a set of when the cost of production, assembling and working conditions were considered. Moreover, the number of revolution of a double-inlet sirocco fan used for an optimum condition was reduced about 8.5% more than that of a standard condition for the target flowrate of $18.5m^3/min$.

패키지 에어컨디셔너의 에너지 절약기술

  • 홍희기
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.9
    • /
    • pp.63-69
    • /
    • 2000
  • 요즈음 업무용에 사용되는 패키지 에어컨디셔너에 대해서도 지구환경문제인 오존층보호와 에너지 절약의 대응이 절박한 상태로서, 여러 가지 제안이 이루어지고 있다. 여기서는 각종규제가 패키지 에어컨디셔너 업계에 미치는 영향에 대한 소개와 열교환기, 압축기 등의 패키지 에어컨디셔너 구성기기의 효율향상에 의한 에너지 절약기술에 대해서 기술하였다.

  • PDF

Study on the Development for Low Noise Indoor and Outdoor Package Air-Conditioner (저소음 패키지 에어컨 실내외기 개발에 관한 연구)

  • Kim, Jang-Kweon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1913-1920
    • /
    • 1996
  • The purpose of this study was to reduce the airborne noise emitted from the package air-conditioner(PAC) therefore, the optimim design melthods of the fans and the flow-paths were investigated experimentally through the anlaysis of the nose problems caused by the conventional PAC system, and the fan performance tests and the systme resistance measurements of the parts which belong to the flow-paths of the PACwere used to study these noise problems. As a results, through the optimized flow-paths of the new PAC system with the lowset system resistance, and by adjusting and matching the operating point of each fan to each PAC system, the airborne noise reductions from the new indoor PAC and the outdoor one were achieved upto 5.5 dBA and 6.6 dBA respectively in overall noise level as compared with the conventional PAC system.

Experimental Study on the Aerodynamic Performance of Double Inlet Sirocco Fan for a Package Air Conditioner (PAC용 양흡입 시로코홴의 공력성능에 관한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-63
    • /
    • 2013
  • The aerodynamic performance of double inlet sirocco fan is strongly dependent upon the design factors of impeller and scroll. In this paper, the change of scroll size was adopted to investigate the aerodynamic performances of double inlet sirocco fan and indoor PAC. Especially, a scroll expansion angle and a cut-off clearance ratio were considered to change the scroll size. In addition, the installation depth between double inlet sirocco fan and indoor PAC was considered. As a result, the total pressure efficiency of double inlet sirocco fan shows about 62%~73% according to the change of scroll expansion angles. Moreover, the flowrate performance of indoor PAC is the best at the condition of a scroll expansion angle of 8°, an installation depth of 15 mm and a cut-off clearance ratio of 8%.

Noise, vibration Characteristic Identification and Noise Control of Indoor Air-Conditioner's Cabinet using Operational Deflection Shape (운행 중 변형형상을 이용한 에어컨 실내기 캐비닛의 소음/진동 특성 파악 및 제어)

  • Lee, Seong-Jin;Oh, Jae-Eung;Lee, Jung-Youn;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.830-833
    • /
    • 2004
  • An indoor package air-conditioner (PAC) has complex noise sources such as motor noise and fluid noise caused by the fan motor, heat transfer and shroud. Sound intensity techniques and ODS(Operational deflection shape) techniques are applied to identify the noise characteristics of an indoor air-conditioner's cabinet. The sound intensity is used to visualize the noise source locations. and the ODS to visualize the vibration pattern and to obtain the dynamic characteristics of the noise source. Acoustic intensity and operational deflection distribution are obtained in space domains as well as frequency domains. Using the visual information of source locations and its dynamic characteristics, the damping patch is applied to reduce structure borne noise in the cabinet. As a result, the noise emitted by the cabinet is reduced by 5dB.

  • PDF

Drop Impact Analysis of Outside Cooling Unit Package of System Air-Conditioner and Experimental Verification (시스템 에어컨 실외기 포장품의 낙하충격해석 및 시험적 검증)

  • Kim, Hyung-Seok;Lee, Boo-Yoon;Lee, Sanghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • This research examines the drop impact of an external cooling unit package of an air conditioner system. The packaging is composed of a shock-absorbing material, which protects the package contents by absorbing the impact energy and other parts for fixture. Accurate quantification of the impact acceleration experienced by the package contents is necessary to design an effective packaging with minimal volume and sufficient shock absorbing capacity. Explicit time integration was used for the drop impact analyses. A finite element model of the package was constructed, material testing and material model selection were carried out, and sensors for data acquisition were modeled to obtain accurate simulation results. The results were compared with real physical test data. Due to imprecise modeling of the damping, the acceleration and strain values predicted by the simulation were larger than those from physical test. However, the trend of the history data and the peak deceleration value in the direction of impact showed good agreements. Thus, the analysis model and scheme are suitable for the design of an air conditioner cooling unit package.

A Study on Developing A Design of Package Air Conitioner For Home use-With a Focus on Goldstar Co Package Air conditioner (가정용 PACKAGE AIR CONDITIONER 디자인 개발에 관한 연구-(주) 금성사 PAC를 중심으로-)

  • 오성진
    • Archives of design research
    • /
    • v.13
    • /
    • pp.153-162
    • /
    • 1996
  • The residence space has been in the trend of being expanded with the J'l'cent economic growth Therefore PAC may be said to have [wen from business use to home US(: the progressed living standard as the goods ior Uw "ummel' S('dSOn rest'ntly though sold in Uw fast for mainly buslTw"s use. PAC has been in the demand day ;lner day and in the tn'nd on the bc,ing the necessJty of the n'sent wf',lther warming phenomenon This study is the case study nf the products development and design process of PAC which has bpcn llrivcn and developed by Gold Star Co. ,Ltd. Which .is the firm for home electric appliances representing Korea. This studies for the development and the design of the products by the firm thus emphasizing the visulizing it based on this study. For example as they being the goods for the summer season I have tried to know the physical quakity and the characters of koreans by the weather conditions and estimated the demand by setting up the target customers of the PAC as the customers' environment. And I analyzed the acts in the living room in the apartments as the living envinorment which has the direct relation with PAC and also became a help to the moulding work of PAC by analyzing the complete interior image in the living room. In the practical moulding work the Design concept was classified into the envinorment of customer, living and products to drive as the below. Firstly - New shape (Round slim) has been realized which leads the minimizing the moulding space and visul sense of opening as its being spacious. The 2nd - the high class sense of the products which are harmonious with the atmosphere of the living room by making it interiorized has been visible. The 3rd - The shape stimulating the sensitivity of the users and surface treatment are emphasized by making it be touched. The 4th - During inviting use of technology image which appears in the electronics products are attemptedby making it be high quality.king it be high quality.

  • PDF