• Title/Summary/Keyword: Partial Admission

Search Result 110, Processing Time 0.031 seconds

Effects of the partial admission rate and cold flow inlet-outlet ratio on energy separation of Vortex Tube (Vortex Tube의 부분유입율과 저온 입.출구비가 에너지분리 특성에 미치는 영향)

  • 김정수;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.51-59
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner for special purpose. The phenomena of energy separation through the vortex tube were investigated to see the effects of cold flow inlet-outlet ratios and partial admission rates on the energy separation experimentally. The experiment was carried out with various cold flow inlet-outlet ratios from 0.28 to 10.56 and partial admission rates from 0.176 to 0.956 by varying input pressure and cold air flow ratio. To find best use in a given cold flow inlet-outlet ratio and partial admission rate, the maximum temperature difference of cold air was presented. The experimental results were indicated that there are an optimum range of cold flow inlet-outlet ratio for each partial admission rate and available partial admission rate.

  • PDF

A Numerical Analysis on the Flow Characteristics within Blades of A Partial Admission Supersonic Turbine (부분입사형 초음속 터빈 익렬내 유동 특성에 관한 수치적 연구)

  • Shin, Bong-Gun;Cho, Jong-Jae;Jeong, Soo-In;Kim, Kui-Soon;Lee, Eun-Seok
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1738-1743
    • /
    • 2004
  • Turbo-pump system, an essential component of liquid rockets and induced weapons, adopts a partial admission axial turbine which drives pump. And the turbine of a turbo-pump system is usually operated at supersonic condition due to its high loading chracteristics. Therefore, reseaches about flow and performance characteristics of a partial admission supersonic turbine must be preceeded to progress the aerospace and defense industries as well as the development of turbo-pump systems. In this study, flow characterisitics within blades of the partial admission supersonic turbine are numerically investigated by using Fine Turbo, a commercial CFD Code. Before performing the numercial analyses, to verify accuracy of the numerical result computed by Fine Turbo, I performed the comparison between the numerical results with J.J.Cho' experimental results. It is found that the numerical results show good agreement with the experimental results. Computations about the partial admission supersonic turbine have been performed to investigate flow characteristics including shock patterns. It is also found that the flow and performance of partial admission supersonic turbine are largely depend on shocks ocurred in the nozzle and at the leading edge of blades, expansion or compression at exit of nozzle and separations occurred in passage.

  • PDF

Numerical Prediction of Unsteady Flows through Whole Nozzle-Rotor Cascade Channels with Partial Admission

  • Sasao, Yasuhiro;Monma, Kazuhiro;Tanuma, Tadashi;Yamamoto, Satoru
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.248-253
    • /
    • 2009
  • This paper presents a numerical study for unsteady flows in a high-pressure steam turbine with a partial admission stage. Compressible Navier-Stokes equations are solved by the high-order high-resolution finite-difference method based on the fourth-order compact MUSCL TVD scheme, Roe's approximate Riemann solver, and the LU-SGS scheme. The SST-model is also solved for evaluating the eddy-viscosity. The unsteady two-dimensional flows through whole nozzle-rotor cascade channels considering a partial admission are numerically investigated. 108 nozzle passages with two blockages and 60 rotor passages are simultaneously calculated. The influence of the flange in the nozzle box to the lift of rotors is predicted. Also the efficiency of the partial admission stage changing the number of blockages and the number of nozzles is parametrically predicted.

Numerical Flow Analysis of a Partial Admission Turbine Using a Frozen Rotor Method (프로즌 로터 기법을 이용한 부분흡입형 터빈 수치해석)

  • Noh, Jun-Gu;Jeong, Eun-Hwan;Lee, Eui-Seok;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.6 s.27
    • /
    • pp.15-20
    • /
    • 2004
  • Numerical analysis of the partial admission turbine in the KARI turbopump has been performed. Flow field of the partial admission turbine is intrinsically unsteady and three dimensional. To avoid heavy computational efforts, the frozen rotor method is adopted in computation and compared with the mixing plane approach. The frozen rotor method can represent the variation of a flow field along the circumferential direction of rotor blades, which have the different relative positions to the nozzle with one another. It also illustrates the wake loss mechanism starting from the lip of a nozzle, which is not captured in the mixing plane method. The frozen rotor method has proven to be an efficient tool for the design of a partial admission turbine.

Experimental Investigation of the Effect of Partial Admission Ratio on the Performance of Supersonic Impulse Turbine (초음속 충동형 축류터빈의 부분분사비 효과에 대한 실험적 연구)

  • Jeong, Eun-Hwan;Park, Pyun-Goo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.4
    • /
    • pp.59-66
    • /
    • 2007
  • In this paper, experimental investigation results of the effect of partial admission ratio on the performance of axial turbine was presented. A supersonic impulse turbine of gas generator cycle liquid rocket engine turbopump was used for the test. for experimental purpose, a nozzle block, in which total 14 number of axi-symmetric convergent-divergent nozzles are arranged circumferentially, was designed and manufactured. Partial admission ratio was controlled by changing the number of active nozzles. High pressure air was used as working medium for the test. The experimental result revealed that the performance of the supersonic impulse turbine does not much affected by the partial admission ratio for supersonic impulse turbine.

CFD Analysis of a Partial Admission Turbine Using a Frozen Rotor Method

  • Noh, Jun-Gu;Lee, Eun-Seok;Kim, Jinhan;Lee, Dae-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.861-866
    • /
    • 2004
  • A numerical flow analysis has been performed on the partial admission turbine of KARI turbopump to support the aerodynamic and structural dynamic assessments. The flow-field in a partial admission turbine is essentially three dimensional and unsteady because of a tip clearance and a finite number of nozzles. Therefore the mixing plane method is generally not appropriate. To avoid heavy computational load due to an unsteady three dimensional calculation, a frozen rotor method was implemented in steady calculation. It adopted a rotating frame in the grid block of a rotor blade by adding some source terms in governing equations. Its results were compared with a mixing plane method. The frozen rotor method can detect the variation of flow-field dependent upon the blade's circumferential position relative to the nozzle. It gives a idea of wake loss mechanism starting from the lip of a nozzle. This wake loss was assumed to be one of the most difficult issues in turbine designers. Thus, the frozen rotor approach has proven to be an efficient and robust tool in design of a partial admission turbine.

  • PDF

Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine (부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구)

  • Cho, Chong-Hyun;Cho, Soo-Yong;Choi, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.324-330
    • /
    • 2005
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

  • PDF

Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine (부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구)

  • Cho Chong-Hyun;Choi Sang-Kyu;Cho Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.13-19
    • /
    • 2006
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

A Study on the Nozzle-Rotor Interactions of Partial Admission Supersonic Turbines

  • Seong, Young-sik;Han, Seong-hoon;Kim, Kui-soon;Park, Chang-kyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.391-397
    • /
    • 2004
  • The performance characteristics of partial admission supersonic turbines are analyzed by using the commercial CFD program FLUENT6.0. The governing equations were discretized with Euler implicit method in time and 2nd-order upwind scheme of FVM in space. The k-$\varepsilon$ turbulence model was utilized to describe the turbulent flow field. In order to investigate the nozzle--rotor interactions and the effect of partial admission, the flows in supersonic turbine rotor cascades with a nozzle are computed. Extensive computations of partial admission supersonic turbines provide the shock structures and flow patterns in the nozzle and rotor. It is clearly shown that the nozzle flow is highly affected by the shocks or expansion waves propagated from the rotor leading edge. And the rotor flow is also affected by the shocks or wakes originated from the nozzle.

  • PDF

Performance Analysis of HP Steam Turbines. of LNG Carriers (LNG 운반선용 증기터빈 고압단의 성능해석)

  • Park, Jong-Hwoo;Chung, Kyung-Nam;Kim, Yang-Ik;Cho, Seoung-Hee
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.275-278
    • /
    • 2006
  • A steam turbine is one of propulsion systems of a LNG carrier, which consists of high pressure (HP) and low pressure (LP) turbines. In order to obtain high power, each one has the form of a multi-stage turbine. Especially, the first stage of a HP turbine is Curtis stage and uses partial admission considering the turbine efficiency. The performance of a HP turbine can be predicted by a mean-line analysis method, because the relatively large value of hub-tip ratio makes the three-dimensional losses small. In this study, a performance analysis method is developed for a multi-stage HP turbine using Chen's loss model developed for the transonic steam turbines. To consider the feature of partial admission, different partial admission models are reviewed, This analysis method can be used in partial load conditions as well as full load condition. The calculation results are also compared with the CFD results about some simple cases to check the accuracy of the program. Performance of two HP turbine models are calculated, and the calculation results are compared with the designed data. The comparison shows the qualitative performance analysis result.

  • PDF