• Title/Summary/Keyword: Partial discharge

Search Result 1,121, Processing Time 0.04 seconds

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

A study of Partial Discharge Condition Monitoring Equipment In the Ultra High Voltage Gas-Insulated Switchgear(GIS) for Digital Sub-station application (디지털 변전소 적용을 위한 초고압 GIS 부분방전 상태감시장치 개발 연구)

  • Kim, Young-Noh;Cho, Young-Jun;Choi, Chul-Gang;Hwang, Chul-Min;Choi, Jae-Ok;Gang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1380-1381
    • /
    • 2008
  • By applying the digital sub-station, the change of various protect and measuring equipments has been applying. This paper is analyzed that the development of GIS partial discharge condition monitoring equipment is suited to the electricity IT technology and digital sub-station. It's constitution apply to be able to suit the data to high rank for GIS partial discharge condition monitoring equipment that is suited digital sub-station and Watch-dog module that be able to monitor the inner communication of the GIS partial discharge equipment. And then it also be able to apply of GIS partial discharge equipment when digital sub-station is applied.

  • PDF

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

The Application of Al-foil Electrode for Detecting Partial Discharge Signal in Middle Joint Box of EHV Power Cable (초고압 전력케이블용 중간 접속부 내의 부분방전신호 검출을 위한 박전극 응용)

  • Lee, Yong-Sung;Yang, Jong-Kyung;Yang, Jong-Keok;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.142-144
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied wi th both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foi1 sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foi1 electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor (가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Choo, Y.B.;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

Investigation of Simulation and Measuring Algorithm of Partial Discharge for Diagnosis of Electric Machinery Deterioration (전력기기 열화 진단을 위한 부분방전 모의 및 측정 알고리즘 개발연구)

  • Jang, Hyeong-Taek;Kwack, Sun-Geun;Shin, Pan-Seok;Kim, Chang-Eob;Chung, Gyo-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.30-38
    • /
    • 2011
  • This paper proposes a new intelligent diagnosis equipment for the partial discharge, which keeps deteriorating the insulating materials inside electric machineries, ultimately leading to electrical breakdown. In order to simulate experimentally the partial discharge inside the electric machinery, the tip-to-plate, the sphere-to-plate, the sphere-to-sphere and the plate-to-plate electrodes are used respectively, of which the gaps are 1[mm], 3[mm] or 5[mm] and the applied voltages are 3[kV], 5[kV] or 7[kV]. Ceramic coupler sensor and FIR digital filter are used to measure the partial discharge and the artificial neural network is used for the deterioration diagnosis of the electric machinery. The microprocessor of PD diagnosis equipment is DSP (TMS320C6713) with FPGA (Cyclone II). The results of the real-time and on-line experiments performed with the developed equipment are also explained.

Influence of Partial Discharge Properties due to Void in Cable Joint Parts (케이블 접속재 부분방전 특성에 미치는 보이드의 영향)

  • 신종열;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF

Considerations on correlation between partial discharge and breakdown using void-simulated defect (보이드 모의결함을 이용한 부분방전과 절연파괴와의 상관관계에 대한 고찰)

  • Lee, Tae-Seong;Jang, Su-Gil;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.21-22
    • /
    • 2011
  • In this paper, considerations on correlation between partial discharge and breakdown using void-simulated defect, investigating the characteristics of void discharges. For the purpose, the relationship between PDIV(Partial Discharge Inception Voltage) and BDV(BreakDown Voltage) was analyzed. As a result, it is noticed that the higher PDIV, the higer BDV.

  • PDF

Considerations on the Propagation of Partial Discharge Pulse in 3-Phase Power Cable Systems including Cross-Bonding Joints (3상 전력케이블 크로스본딩 접속에서 부분방전 펄스 전파 특성 고찰)

  • Kim, Jeong-Tae;Kim, Dong-Uk;Kim, Ji-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1606-1607
    • /
    • 2011
  • In this study, the propagation characteristics of partial discharge(PD) pulses in the 3-phase cable systems including crossbonding joints were discussed. For the purpose, experiments for 22.9kV CNCV cables were performed using simulated PD pulses, and on-site partial discharge measurements were carried out for the 345kV XLPE cable system.

  • PDF